SCORE 100 1 N 20th St Philadelphia Pa 191031418 Install 51-led 2x4 flat panel lights,2-new panels,1-new transformer,new meter,24-duplex recepts and 3-gfi recepts as per 2008 nec (cc district) install 10-exit signs,8-emergency lights,9-new switch occupany sensor,8-ceiling occupancy sensor,fire alarm devices and strobes and horn strobes as per nfpa72 Client: Phila Auth Ind Dev C O Atwen Associates | Client Company: Norman Wolgin | Permit type: Electrical permit | Permit status: Active | Completion date: November 16, 2017 | Permit id: 824552 | |||||
SCORE 100 21315 S 16th St Philadelphia Pa 191023303 Install new light, new recepts, new floor recepts, new electric panel & lighting control as per nec 2008 cc district Client: Racquet Club | Permit type: Electrical permit | Permit status: Completed | Completion date: September 23, 2016 | Permit id: 621480 | |||||
SCORE 100 907 S 10th St Philadelphia Pa 191473725 Interior renovations for new power and lighting, 120v smoked detectors, 5 daisy chained together as per 2005 nec Client: Adams Beryn Kanchanahoti Oytip | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 51330 | |||||
SCORE 100 5416 N 12th St Philadelphia Pa 191413008 Install 2 strobes, 9 horn strobes, 1 nac panel & 1 duct detector. Client: Albert Einstein Medical Center | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 292913 | |||||
SCORE 100 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: May 28, 2008 | Permit id: 125013 | |||||
SCORE 100 221 S 34th St Philadelphia Pa 191043803 F&i (2)800amp distribution panels & feeders (1)4 amp panel & feeders (1)125a panel (1)100a panel (1) kva xfmr & branch wiring to new hvac units fa f&i new vesda duct detectors tied to existing fa system per 2008 nec & nfpa 72 (university) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: November 13, 2014 | Permit id: 491725 | |||||
SCORE 100 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 406247 | |||||
SCORE 100 Client: Philadelphia Authority Fowalnut Towers Associates | Permit type: Electrical permit | Permit status: Completed | Completion date: July 18, 2012 | Permit id: 400119 | |||||
SCORE 100 3701 Market St Philadelphia Pa 191043101 Install duplex receptacles qty 7 and box and string qty 7 per 2008 nec (commercial) Client: University City Science Center | Client Company: Science Center Assoc Lp | Permit type: Electrical permit | Permit status: Expired | Completion date: February 22, 2016 | Permit id: 671335 | |||||
SCORE 100 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 405792 | |||||
SCORE 100 141222 Fairmount Ave Philadelphia Pa 191302908 Install 16 smokes detectors 4 horn strobes and 2 strobe only per 2008 nec & nfpa 72 (health care facility) Client: Elaware Valley Communityhealth Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2013 | Permit id: 470471 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Install (7) 2x2 fixtures,(30) down lights,(1) exit sign,(3) switches,(16) receptacles, all in accordance with attached drawings and 2008 nec (west dist) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 300023 | |||||
SCORE 100 3001 Red Lion Rd Philadelphia Pa 191141123 We are doing a 1 for 1 fixture swap (2 x 4s) approximately 2 and are being directed by the owner as to which fixtures to replace. No new wiring, all existing circuits. Client: Packaging Coordinators Ll | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 359465 | |||||
SCORE 100 Permit type: Electrical permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 265840 | |||||
SCORE 100 3401 W Girard Ave Philadelphia Pa 191040000 Install temporary power for event tent from 1 kw generator supplied by other, 10 17 2008 to 10 19 2008 as per 2005 nec (west dist) Client: City Of Phila West Park Mann Music | Permit type: Electrical permit | Permit status: Completed | Completion date: February 10, 2009 | Permit id: 182539 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Install 12 gfi recept 1 junction box power 1-208v recet, power for heat puump, electirc hat, 6 lihgt fixtures and 2 switches as per 2008 nec (east district) Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Expired | Completion date: July 25, 2016 | Permit id: 694441 | |||||
SCORE 100 80129 Locust St Philadelphia Pa 191075507 Install low voltage voice and data cables 12 voice & 12 data cat 5e test and terminate, longest run 1 as per 2005 nec (cc district) Client: American Postal Workers House Assoc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 129386 | |||||
SCORE 100 100834 Locust St Philadelphia Pa 191075770 Install new light, new recepts, new floor recepts, new a c unit & new electric panel as per nec 2008 cc district Client: Thomas Jefferson University | Client Company: Treasurers Office | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 621479 | |||||
SCORE 100 2001 Market St Philadelphia Pa 191031415 Install voice and data cable cat5e type longest length of cable 100. 17 cable locations. Seco #9518 (cc dist) Client: Maguire Thomas Ptns Phila Plaza Phase Ii | Client Company: Commerce Square Partners | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 177906 | |||||
SCORE 100 36 Pine St Philadelphia Pa 191040000 (2)15kv incoming lines,new 15kv medium voltage switch gear (2)500kva transformers & lv subs,transfer existing loads to new gear demo & remove old gear,misc branch light & power per 2008 nec (classrooms) Client: Trustees Of The U Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: October 29, 2014 | Permit id: 519976 | |||||
SCORE 100 615 Chestnut St Philadelphia Pa 191064404 5 duplex recept, 11 light fixtures, 1 box & string, 1 electric ceiling heater, 1 connection for outside sign, no fire alarm work as per (cc district) Permit type: Electrical permit | Permit status: Completed | Completion date: September 18, 2008 | Permit id: 158117 | |||||
SCORE 100 1301 E Montgomery Ave Philadelphia Pa 191252701 Temp light and gfi recetps for new construction site, separate permit to be applied for upon completion of stamped drawings for permanent work, temp will be in place for 6 months (east district) Client: Pappajohn Matthew Pappajohn Ian | Permit type: Electrical permit | Permit status: Completed | Completion date: December 11, 2007 | Permit id: 104924 | |||||
SCORE 100 1 E Erie Ave Philadelphia Pa 191341009 Construction for new facility to provide temp residence for families of children under care of st. Chriss hosp. Includes service to building, lighting, power and emergency generator. No fire alarm on this job. As per nec 2005 Client: Phila Ronald Mc Donald House Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 57892 | |||||
SCORE 100 32 Walnut St Philadelphia Pa 191043400 3 switches, receptacles,16 light fixtures,2 panels,2 disconnect,buss plug switches,1 horn strobes,2 new feeders per 2008 nec & nfpa 72(university complex) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2015 | Permit id: 548674 | |||||
SCORE 100 31 Penrose Ferry Rd Philadelphia Pa 191455537 Install approximately (700) flourescent fixtures, (45) exit signs, (80) switches, (3 receptacles, (9) panels and (3) transformers in accordance with 2005 nec.(south dist) Client: Phila Housing Authority | Client Company: Phila Housing Authority | Permit type: Electrical permit | Permit status: Completed | Completion date: March 23, 2009 | Permit id: 112934 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Renovation 3 light fixtures, 1 switch, 3 duplex receptacles, 1 gfi receptacle, 2 teledata pathways only. Relocate 6 receptacles, 1 gfi receptacles, 2 teledata pathways only. All teledata cabling and devices are by others asper nec 2008 west district Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2017 | Permit id: 744275 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install 3 speaker strobes, 5 strobes, 8 smoke detectors & 2 doorholders. Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 8, 2010 | Permit id: 312410 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 159 new recepts, 28 switches, 123 lights, 3 new electric panels and feeders, additional nurse call equipment as per 2008 nec (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Expired | Completion date: January 6, 2015 | Permit id: 509979 | |||||
SCORE 100 46 S Broad St Philadelphia Pa 191120000 Showroom officesinstall approx 4 ltg fi,36 ltg ctl devices,8 panels,1 transformer,1 meter,2 recepts,45 fire alarm devices,146 cat6 voice drops,6 catv drops,1 overhead cabletray & 2 patch cords as per 2008 nec & nfpa7 Client: United States Of America | Client Company: Comm Off Northern Div | Permit type: Electrical permit | Permit status: Completed | Completion date: April 20, 2013 | Permit id: 392472 | |||||
SCORE 100 179 Mifflin St Philadelphia Pa 191482017 Retail-rework casework for target store. Add one power pole as per 2008 nec ( Client: Target Corporation | Client Company: Target Corp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 387876 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 New 15 kva service feeders for new panels & chillers, new lighting in stair tower & penthouse area new recept in penthouse & roof as per nec 2008 Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Expired | Completion date: October 26, 2012 | Permit id: 428686 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 20 light fixtures, 3556 recepts, 731 light switches, 296 occupancy sensors, 529 nurses call devices, 1369 pathways for teledata (t d wiring by others). Switchgear & f a by others. Installation to comply with article 517. 13 of the 2008 nec. Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: January 6, 2015 | Permit id: 506149 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 New light fixtures (63),new exit signs (5), single pole switches (8),dimmers (2), new nurse call, new panels (2), transformer (1),duplex receptacles (82),seco job #1142, as per 2008 nec (north dist) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 8, 2010 | Permit id: 303754 | |||||
SCORE 100 370115 Chestnut St Philadelphia Pa 191043104 Upgrade feeder to panel "a" 200amp 3 phase furnish and install panel "b" and feeder 150amp 3 phase per 2008 nec (mixed use) Client: Nternational House | Permit type: Electrical permit | Permit status: Completed | Completion date: February 3, 2014 | Permit id: 505350 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 This permit is being provided because (3) additional smoke dampers were added to this project. Please reference our permit #214613 date 5 12 09 for further details as per 2008 nec (east dist) Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Completed | Completion date: September 13, 2010 | Permit id: 288471 | |||||
SCORE 100 14046 N Christopher Columbus Blvd Philadelphia Pa 191062001 Install new 1 panel, lighting & branch ckt as per nec 2008 (restaurant) Client: Philadelphia Fringe Festi | Permit type: Electrical permit | Permit status: Completed | Completion date: November 24, 2014 | Permit id: 546634 | |||||
SCORE 100 90737 Market St Philadelphia Pa 191073110 Replace 117 existing light fixtures with new. No new wiring. Seco #1477 Client: Phila Redevelopment Authority | Client Company: Phila Redevelopment Auth | Permit type: Electrical permit | Permit status: Completed | Completion date: September 19, 2011 | Permit id: 354365 | |||||
SCORE 100 Client Company: Tax Administration | Permit type: Electrical permit | Permit status: Completed | Completion date: March 15, 2011 | Permit id: 265841 | |||||
SCORE 100 302052 Market St Philadelphia Pa 191042801 Install 1 pull station, 12 smoke detectors, 13 speaker strobes and 1 nac panel. All wiring in fpcp cable seco # 9991 as per nfpa 72 (west district) Client Company: Tax Administration | Permit type: Electrical permit | Permit status: Completed | Completion date: March 15, 2011 | Permit id: 270785 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 New lights, recepts, switches, panels no fire alarm work as per 2005 nec (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 129388 | |||||
SCORE 100 220 S 34th St Philadelphia Pa 191043804 48-smokes, 19-spkr strobes, 2-pullstations, 12-duct det, 140-lgt fix, 74-poke thru, 4-pnl, 80-recpts, 12-proj screens, 80-lv sw, 24-occ sensors & empty conduit for tele data & sec as per nec 2008 & nfpa72 (school) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2014 | Permit id: 479800 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install receptacles, light fixtures, switches, dimmers, panel, 45kva transformer & feeder per plans. Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 282625 | |||||
SCORE 100 501 Osler Cir Philadelphia Pa 191400000 Connect to existing circuits, paels, remove research replace existing llighting fixtrues & devices, provide new device fixtures as per 2008 nec (west district) relocate proved new fire alarm devices tied into box and stubs as per nfpa72 Client: Trustees University Of Penna | Permit type: Electrical permit | Permit status: Expired | Completion date: March 31, 2017 | Permit id: 765174 | |||||
SCORE 100 5 Osler Cir Philadelphia Pa 191040000 Research lab renovation branch power to gasketed receptacles and lighting (1) new 2 section panel board new fire alarm notification and initiating devices on existing head end equipment per 2008 nec & npfa 72(university) Client: University Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2014 | Permit id: 477219 | |||||
SCORE 100 4900 Frankford Ave Philadelphia Pa 191242618 Health care facility-install 32 light fixtures, 8 single pole switch, 27 duplex recepts & 15 box & conduit as per 2008 nec (east dist) Client: Frankford Hospital Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: December 15, 2011 | Permit id: 369702 | |||||
SCORE 100 3520 Market St Philadelphia Pa 191043303 Install (40) switches, (120) receptacles, (140) florescent light fixtures, (8) exit signs and (1) 2 amp panel,. In accordance with nec. (west dist) Client: Mref Ii 35 Market Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 91549 | |||||
SCORE 100 5 Osler Cir Philadelphia Pa 191040000 Demo lighting & branch power-install lighting, wiremold, receptacles & raceway for communications as per nec 2008 west district Client: University Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 579179 | |||||
SCORE 100 38 Powelton Ave Philadelphia Pa 191042300 (43) lts, (6) exit lits, (6) panels, (6) combination starters (small), (12) disconnect switches, (98) submeters, (1) 4 amp transfer switch, (95) recepts, (19) gfi recept., (1) smoke detector, (6) a-v, (15) strobes, (3) duct smoke detectors, (2) pull stations, (11) nurses call stations, (4) dome lights. (west dist) Client: Presbyterian Medical Centpenn Presbyterian Medical | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 91548 | |||||
SCORE 100 36 Pine St Philadelphia Pa 191040000 Replace existing service equip 15kv medium voltage switch gear, double ended with auto transfer, new unit sub stationdoulbe ended 1500kva, new otdoor sub station double ended 15 kva suto transfer, distri from new equip to existing loads, demo old equip as per 2008 nec (west district) Client: Trustees Of The U Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: June 28, 2016 | Permit id: 551182 | |||||
SCORE 100 12434 S 15th St Philadelphia Pa 191023002 Install 13 cat5e data cables for new pos system max length of cable 1 seco 2144 per 2008 nec (restaurant) Client: Goodsam 15 Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: October 3, 2013 | Permit id: 489645 | |||||
SCORE 100 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 344072 | |||||
SCORE 100 340646 Walnut St Philadelphia Pa 191043411 Replace existing electric meters. As per nec 2008 basement school Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 408246 | |||||
SCORE 100 121723 Vine St Philadelphia Pa 191071111 Temp power and lighting,electrical demo lighting,exit and emergency lighting,duplex recepts,all branch wire as per 2008 nec(cc district) Client: Asian Arts Initiative | Permit type: Electrical permit | Permit status: Completed | Completion date: November 4, 2015 | Permit id: 588603 | |||||
SCORE 100 340646 Walnut St Philadelphia Pa 191043411 New panels feeders and equipment to support hvac upgrades in accordance with nec and city of phila codes fire alarm equipment and testing of new vesda duct detectors for air handler replacement units Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Active | Completion date: September 28, 2017 | Permit id: 812876 | |||||
SCORE 100 120111 Walnut St Philadelphia Pa 191074914 Install 40amp dedicated cir for equiptment as per 2008 nec Client: Northwest Corner Twelfth And Walnut L P 50% Int | Permit type: Electrical permit | Permit status: Expired | Completion date: July 18, 2012 | Permit id: 400116 | |||||
SCORE 100 100141 Walnut St Philadelphia Pa 191075001 2-gfi recpts, 4-single pole switches, 4-hand dryer, new lighting & occupancy sensors as per nec 2008 (hospital) Client: Jefferson Med College Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 528044 | |||||
SCORE 100 1522 Walnut St Philadelphia Pa 191023601 New 16 amp service, new light fixtures & controls, new recpt - no fire alarm work included as per nec 2008 (retail) Client: Robert G Levin Irrevocabl | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2013 | Permit id: 438075 | |||||
SCORE 100 3600 Walnut St Philadelphia Pa 191043812 Relocate 1 electric meter (non-utility) and furnish and install 2 additional electric meters as per 2008 nec Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 405808 | |||||
SCORE 100 340646 Walnut St Philadelphia Pa 191043411 Installation of new receptacles and lighting in renovated seminar room as per 2008 nec. (west district) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: October 28, 2015 | Permit id: 612548 | |||||
SCORE 100 1522 Walnut St Philadelphia Pa 191023601 New fire alarm work second and third floors per 2008 nec & nfpa 72 (commercial) Client: Robert G Levin Irrevocabl | Permit type: Electrical permit | Permit status: Expired | Completion date: August 10, 2013 | Permit id: 449304 | |||||
SCORE 100 3300 Walnut St Philadelphia Pa 191043409 3-panel & dist to recpt lgt & hvac units per plans. Smoke detector, pull stations, duet detectors, added to existing f. A. System per plans as per nec 2008 & nfpa 72, local & state codes (comm) Client: Trustees For Moore School Of Elec Eng | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 437269 | |||||
SCORE 100 Client: Walnut St Theatre | Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2008 | Permit id: 171361 | |||||
SCORE 100 340646 Walnut St Philadelphia Pa 191043411 Replacement of medium voltage, switchgear in van pelt, replacement of unit substations in van pelt & dietrich, refeed existing loads from new gear, replace 15kv feeders from mh to new mvsg per 2008 nec (university) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: March 26, 2014 | Permit id: 475252 | |||||
SCORE 100 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 344071 | |||||
SCORE 100 340139 Walnut St Philadelphia Pa 191043410 New univ of penn standard luminaries (129) to be fed from peco street lighitng circuits as indicated. (west dist) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: May 28, 2008 | Permit id: 125014 | |||||
SCORE 100 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: May 28, 2008 | Permit id: 125012 | |||||
SCORE 100 360151 Walnut St Philadelphia Pa 191043800 Install cats cable for phone and pos system qty as per 2008 nec (west dist) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Expired | Completion date: August 28, 2015 | Permit id: 635207 | |||||
SCORE 100 1632 Walnut St Philadelphia Pa 191035403 Install 21 duplex recepts,install 11 box & conduit. Install new lighting,13 type l-1,5 type l-2,3 type l-3,2 type l-4,3 type l-5,1-3 and 7-4 type l-6 and type low bay as per 2008 nec Client: Adr 1632 Walnut St | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2012 | Permit id: 397655 | |||||
SCORE 100 36 Spruce St Philadelphia Pa 191044211 Fire only-45 lt, fixs, 17 sw, 45 recepts, 1 new 100a panel, as per plans Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 39897 | |||||
SCORE 100 23034 W Washington Sq Philadelphia Pa 191063522 Renovation of 6 existing exam rooms conversion of 3 offices to exam rooms 2 switches 46 receptacles 4 gfi recs 5-2x4 fixtures 9 x-ray viewing lighting cabinets 2 empty tele data conduit drops per 2008 nec (health care facility) Client: Contributors Of The Penns | Client Company: Jerome Smalls | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 467010 | |||||
SCORE 100 25 Spring Garden St Philadelphia Pa 191300000 Electr demo, lighting and brance power in kitchen, new feeds to elevators, lighting & power for elevators, wire and install 2-100amp pnaels, 3 pha 120 208v security system temp power and lighting as per 2008 nec (west district) install fire alarm system as per nfpa72 Client: City Of Phila Art Rodin Lemon Hill | Client Company: Municipal Services Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: August 26, 2014 | Permit id: 551183 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Add 1 receptacle,1 light switch and relocate 1 switch (health care) Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 749114 | |||||
SCORE 100 Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Expired | Completion date: May 30, 2017 | Permit id: 779078 | |||||
SCORE 100 390103 Spruce St Philadelphia Pa 191044112 Removal of double ended sws gear installation of new. Replacement of panel feeders and interiors. Distribution to new and relocated mechanical equipment per nec 2005. (infrastructure only - no work in units) (west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2008 | Permit id: 148341 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Install new conduit feeder along w new 300a panel as per 2008 nec (health care facility) Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 400109 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Install approx 4 fluor fix 76 switches 5 recept 96 fire alarm devices 22 paging spkr 1 100a ats 1 75 kva xfmr & 6 panels in accord w attached drawing as per nec 2008 & as per nfpa 72 Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 412483 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Install conduits as per 2008 nec(commercial)(cc dist)installation to comply with article 300. 21 of the 2008 nec. Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: July 18, 2012 | Permit id: 405785 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Replace 2 existing lights with new,replace existing single pole switches with new type occupancy sensors,replace existing receptacles with new new per 2008 nec(health care) Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Expired | Completion date: May 10, 2017 | Permit id: 773637 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Install approx receptacles, switches, 42 floor fixtures, 2 - 100am panels as per 2008 nec (cc district) fa devices as per nfpa 72 (maintenance shop-hospital) Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: June 6, 2012 | Permit id: 376996 | |||||
SCORE 100 3800 Walnut St Philadelphia Pa 191043605 Replace existing electric meter as per 2008 nec(school)(west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 405793 | |||||
SCORE 100 71139 Spring Garden St Philadelphia Pa 191233507 New 15 kv service, new fire alarm system, new emergency call system, added (49) exit lights, (8) emergency lights, (11) wall packs, (6) pole lights, (23) interior lights, (33) receptacles, (282) gfi receptacles, power for (91) heat pumps, (2) boilers. (cc dist) Client: Guild Rehab Program | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 101368 | |||||
SCORE 100 3300 Walnut St Philadelphia Pa 191043409 Rewire (2) existing electric meters (non-utility) per 2008 nec Client: Trustees For Moore School Of Elec Eng | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 409806 | |||||
SCORE 100 100028 Walnut St Philadelphia Pa 191075517 Install 1-new 100amp 120 208 volt 4w electic panel, install single pole switches, install 60-new lights fixtures & security equipment as per nec 2008 (medical school) Client: The Jefferson Med College Of Phila | Client Company: Treasurer Room 611 | Permit type: Electrical permit | Permit status: Completed | Completion date: March 21, 2013 | Permit id: 436882 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Replace med voltage incoming serv switchgear- 2-secondary branch pnl, 1- kva trans, peco meter cabinet, 11-recpts, 8-gfi recpts, 88-lgt fixtures, 6-lgt sw, 5-teledata pathways only as per nec 2008 (hospital) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: June 8, 2016 | Permit id: 599504 | |||||
SCORE 100 370034 Walnut St Philadelphia Pa 191046216 Replace 3 existing elec meters and furnish and install 2 new electric meters as per 2008 nec (school) Client: The Trustees Of University Of Pa | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 405803 | |||||
SCORE 100 70014 Spruce St Philadelphia Pa 191064007 Installation of 92 floor fix, 7 exits, switches, 46 receptacles & relocation of 1 panel as per 2008 nec (cc dist) medical office Client: Contributors To The Penns | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: December 24, 2012 | Permit id: 368301 | |||||
SCORE 100 70014 Spruce St Philadelphia Pa 191064007 Install 21 fluor fix, 7 sw. 35 recepts, 2 mech equip conn in accordance with nec 2008(health care facility)(cc dist) Client: Contributors To The Penns | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2012 | Permit id: 384137 | |||||
SCORE 100 1500 Spring Garden St Philadelphia Pa 191304009 Install 1 smoke detector, 2 pull stations, speaker strobes 1 power booster as per 2005 nec (cc district) Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2008 | Permit id: 113409 | |||||
SCORE 100 23034 W Washington Sq Philadelphia Pa 191063522 Renovation of reception and registration area along with a staff lounge upgrade 5 switches, 6 duplex receptacles, 1-30amp receptacle, 4 exits, 3 source speakers, 2 gfi recs, 3 high hats, and 2 quad receptacles per 2008 nec (health care facility) Client: Contributors Of The Penns | Client Company: Jerome Smalls | Permit type: Electrical permit | Permit status: Completed | Completion date: July 27, 2013 | Permit id: 472065 | |||||
SCORE 100 23034 W Washington Sq Philadelphia Pa 191063522 Add 2-horn strobes, 1-strobe, 2-door holders, relocate 1-horn strobe & 1-smoke detector as per nec 2008 & nfpa 72 (health care fac) Client: Contributors Of The Penns | Client Company: Jerome Smalls | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 476692 | |||||
SCORE 100 1500 Spring Garden St Philadelphia Pa 191304009 Install (196) receptacles, (488) light fixtures, (46) switches, (22) exit signs, (8) panels, (2) xfmrs, (55) fire alarm speaker strobes, (3) pull stations, (4) smoke detectors, in accordance with (attached drawings) nec (cc dist) Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2008 | Permit id: 102571 | |||||
SCORE 100 1500 Spring Garden St Philadelphia Pa 191304009 Partial 1st, 5th, 9th, 10th, 11th, core & shell work. Install 16 panels, 4 step down xfmers, 11 submeters, 24 8 fluor fixtures, 12 4 fluor fixtures, 26 down lights, 52 2 wall fixtures, 25 toggle switches, recpts according to attached plans. Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2008 | Permit id: 93610 | |||||
SCORE 100 345759 Walnut St Philadelphia Pa 191043410 Replace existing sw gear and svs. Furnish and install 27 lts, 15 emerg lts, 8 recepts. (west dist) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: November 26, 2007 | Permit id: 78365 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install security devices - cabling for as per plans for infant monitoring purposes - as per 2008 nec Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 395944 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 F&i 314-lgt fix, 42-toggle sw, 24-dimmer, 43-occ sensors, 1-photocell, 257-dup recpts, 14-gfi recpts, 2-branch pnl board, 1-225 kva trans 5-f a pull stat 11-sm det, 4-duct etc (health care) as per nec 2008 & nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 13, 2014 | Permit id: 528996 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install (11) 1 volt receptacles, (2) switches, (4) 2x2 floor fixtures in accordance with the drawings as per 2008 nec (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2011 | Permit id: 348877 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Installation of 5 receptacles, 4 light switches, 4 lighting fixtures & misc. Demo in accordance attached drawings. Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2008 | Permit id: 57861 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovate f&i 82 light fixtures, 6 toggle switches, 15 dimmers, 9 occupancy sensors, 37 duplex recepts, 3 gfi recepts, 6 quads, 4 panel boards, 27 teledata(cable & devices by others) as per 2008 nec (west district) smokes, 2 speaker strobes, 2 strobes, 13 paging speakers as per nfpa72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: October 28, 2015 | Permit id: 615719 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Furnish and install 12 light fixtures 6 receptacles 4 quad receptacles power for 9 small pieces of equipment pathways only for tele data outlets per 2008 nec (health care facility) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: June 21, 2013 | Permit id: 440448 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 F & i 4-duplex recpts, 11-quad recpts, power 1-vav, 1-lgt sw, 2-occup sensors, 12-lgt fixtures, 1-speaker, & 13-tele data pathways only (teledata wiring & devices by other) as per nec 2008 (hospital) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 532444 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 2-duplex, 2-quad recepts, 2-connections for systems furniture, 2-pathways for teledaya (t d wiring & devices are by other) as per nec 2008 (health care) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: May 11, 2015 | Permit id: 586725 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovate relocate 2 light fixtures, f&i 4 light control stations, 1 recept, 1 eop switch, 2 door switches, 2 branch panelboards 45 medical wall duct, 24 low volt cable pathways only (cable & devices by others) as per 2008 nec (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: September 16, 2015 | Permit id: 618336 | |||||
SCORE 100 4201 Spruce St Philadelphia Pa 191044022 Addition of 3 new panels and associated conduit, wire feeders for future branch power expansion as per 2005 nec(cc dist) Client: Univ City Assoc Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: May 28, 2008 | Permit id: 140672 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 4 electric panels 1-15kvz transf 1-160kva up1-3 amp enclosed cirt breaker 1-8 amp cirt breaker for existing substation 1-125 amp bucket for exisitng mcc, 5 recpets 77 light fixtures 5 light sw 15 dimmer switches 3 epo switches raceways for siemens cable as per 2008 nec (west district. Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 667701 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install 4 new light fixtures. Install 1 new occ sensor. Install 1 new sws and replace existing receptacles with tamper proof per 2008 nec (health care) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Active | Completion date: August 17, 2017 | Permit id: 765613 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install 2 switches, 1 double duplex recept, 3 gfi recepts, 2 under cabinet lights, 1 nurse call station as per 2008 nec (west district) install 1 strobe only as per nfpa72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: July 18, 2016 | Permit id: 699794 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 209 light fixture 81 switches 426 receptacles power for 2 radiamt panels. 2 exhaust fans 1 ahu 3 100a panels, one 125a panels one 15kva transformers. 64 nurse call devices, 11 paging speakers fire alarm smoke detectors 6 duct detector 8, remot test sw8 storbe 7, speaker strobes 9, nas extender 1, add module 2, relay 11, dour holder4, tel data tu pathway 94 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: May 25, 2017 | Permit id: 766747 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 2-800 3p circuit breakers,2-conn to exist 800 3p circuit breaker;1-600 3p automatic transfer sw;1-800a 3p automatic transfer sw;2. 400 3p 3r disconnect sw;4-30 3p disconnect sw;1-400a 3p motor conn,4-30 3p motor conn 2-400 3p mlo pnlboard,2 install mpz;14 install vfd,14-30 3p motor conn,4 fixtures,8 jbox & conn;6ddc jbox & conn per 2008 nec (health care)1-connn to ex remote annunciator,fire alarm,8 duct mtd smoke detectors per nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 826133 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Add electrical panel and outlets for new bed shop per 2008 nec Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 417736 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Remove and reinstall 23 receptacles, 9 light switches, 9 light fixtures, disconnect dishwasher and intercom and utilize existing power for new equipment as per 2008 nec Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2010 | Permit id: 282924 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 221 lt fxts, 31 swit, 28 occup sensors, 397 recp, pwr for 1 air handler, 15 pnls, 1-260amp transfer swit, 1 75kva & 2 15kva transfrmr, 9 vfds(5 to hp) & assoc pwr for motors, 63 fa devices, 18 security devices as per 2008 nec & nfpa 72(hospital) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 424132 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install approx. 35 switches, 175 recepts, 126 floor fixtures, 12 panels devices andassorted branch wiring as per 2008 nec (west district) 18 fire alarm devices as per nfpa72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: May 19, 2011 | Permit id: 316227 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install 1 switch, 8 receptacles, 2 tele data pathways only, 1 speaker & 1 microphone. Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2014 | Permit id: 558710 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 F & i 22-light fixtures, 4-toggle switch, 3-occupancy sensors, 15-duplex recept, 4-furniture feeds & 5-speakers strobes as per nec 2008 & nfpa 72 (hospital) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: January 8, 2015 | Permit id: 558962 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 5-mcc buckets w feeder, 2-branch ckts pnl, 1-30kva transformer, 27-lgts fixtures, 8-30amp disconnect sw for mech loads, 1- 10-hp, 3-tele data pathway only 20 control wire power for 18-mech load as per nec 2008 west district Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 605408 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovation:f & i,2-light fixtures,2-toggle switces,1-dimmer,10-duplex receptacles,2-quad receptacles,1-singel receptacle,1-branch panelboard, 2-teledata pathways only(cable & devices are by others),3-epos,instlal only 1-50kva ups,5-surgical booms as per 2008 nec(west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 643211 | |||||
SCORE 100 400127 Spruce St Philadelphia Pa 191044024 Installation of a new voice evac. Fire alarm system @ evans hall (west dist) Client: The Thos W Evans Museum Ins Soc Of Univ Of Pa | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 83976 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 New 100a bucket in mcc,75kva transforner,grounding,200amp 3phase panel,cable tray,support work for wireless antenna system as per 2008 nec (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Active | Completion date: August 14, 2017 | Permit id: 799244 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install approx,78 floures fix,24 sw,2-60a panels,68 recepts,6 nurse call devices as per 2008 nec ,15 fire alarm devices,as per 2008 nec & nfpa72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: June 21, 2012 | Permit id: 397645 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 1 install lighting fixtures, switches,285 receptacles,5 equip conn,(2)100amp panel,(2)100amp cb, 27 security devices,7 paging speakers,57 data box & stub,furnish & install nurse call devices to existing system per 2008 (health care)install 15 fire alarm devices per nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Active | Completion date: October 17, 2017 | Permit id: 815319 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Installation of panels, 21 floor light fixtures and owners supplied vps equipment in according with attached drawing as per 2008 nec, health center Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 370627 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovation 59 light fixtures, 6 toggle switches, 17 dimmers, 6 occupancy sensors, 61 duplex recepts, 5 gfi recepts, 6 sinle recepts, 1 branch panel board, 25 tele data, 6 epo, power for ac 7 nurese call devices as per 2008 nec (west district) cable and devices by others Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 542484 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 4 duplex receptacles,4 quad receptacles,5 connections for system furniture,8 light fixtures and 5 occupancy sensors per 2008 nec (health care) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 4, 2015 | Permit id: 590900 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 183 lights fixtures,19 receptacle,6 gfi rec,power for 5 sys furniture connections,power for sink solenoid,15 tele data pathways(cabling done by others)1 nurse call dome light,1 nurse call pull cord station per 2008 nec (health care) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 624693 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Replace existing fire pump and feeder with new per 2008 nec & nfpa 72 (health care facility) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 548673 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Provide & install the following, 26 recepts, 72 fluor light fixtures, 14 switches, 5 smoke det, 6 horn strobes, 1 pull station & the relocation of 5 existing smoke det (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 83977 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install the following: 135 recepts, fluor. Fixtures, 4 emetg batt units, 14 switches, relocate misc fire alarm devices and provide panel feeders (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2008 | Permit id: 83978 | |||||
SCORE 100 340199 Spruce St Philadelphia Pa 191044203 Furnish and install 1 electric meter and rewire 2 existing meters as per 2008 nec(school)(west dist) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 406246 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Healthcare facility-install approx 2 recepts,284 floor fixtures,2 transformers & 16 panels feeders & conduits as per 2008 nec (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: April 20, 2013 | Permit id: 387085 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Health care facility-instalapprox 1 flvor fix,18 exit signs,45 sw,1 recepts,3 panels,1 xfmr, f a devices &8 misc mech equip. Connsas per 2008 nex & nfpa72 (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 389061 | |||||
SCORE 100 213246 South St Philadelphia Pa 191461227 Install 126 cat 5e voice and data cables max length 175 as per 2008 nec (cvs)installation to comply with articles 300. 21 & 8 of the 2008 nec. Client: Philadelphia Pharmacy Dst | Permit type: Electrical permit | Permit status: Completed | Completion date: December 11, 2012 | Permit id: 421353 | |||||
SCORE 100 29 South St Philadelphia Pa 191460000 Furnish and install new electric meter (non-utility) per 2008 nec Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 409802 | |||||
SCORE 100 17 South St Philadelphia Pa 191461526 Install 20-light fixtures,7-recepts,2-light switches,2-occupancy sensors,1-pathway for teledata(t d wiring and devices are by others),4-smoke detectors as per 2008 nec(west district) install 1-heat detector and 1-horn strobe as per nfpa72 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: July 25, 2017 | Permit id: 654674 | |||||
SCORE 100 38 Spruce St Philadelphia Pa 191044111 Install new lighting,receptacles and fa 55 receptacles,9 switches,1 lighting control panel,83 light fixtures,9 strobes only,1 pull stations,1 tamper switch,1 flow switch and 1 nac panel per 2008 nec & nfpa 72(animal services) Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 570275 | |||||
SCORE 100 38 Spruce St Philadelphia Pa 191044111 New power distribution to new ele rms,transfer of branch loads,demo of old diestriubtion,electrical support for new hvac equip per 2008 nec (univeersity complex)add new fa duct detectors for hvac equip per nfpa 72 Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: February 3, 2016 | Permit id: 664368 | |||||
SCORE 100 3220 South St Philadelphia Pa 191460000 Furnish and install new ele meter and rewire existing non-utility meters as per 2008 nec(penn museum)(south dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 410105 | |||||
SCORE 100 80121 Spruce St Philadelphia Pa 191075700 Install 4 new panels, new normal & emergency power as required for new dialysis area, install nurse call for patient areas & new lighting as per nec 2008 (cc district) replace or relocate devices on existing fire alarm system Client: Contributors To Penna Hospital | Client Company: Pennsylvania Hospital | Permit type: Electrical permit | Permit status: Expired | Completion date: March 29, 2016 | Permit id: 659518 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 1 light fixtures, 44 switches 21 dimmers, 5 occ sensors, 164 receptacles, power for 9 fan coils, 15 surface raceway, 28 teledat pathways only wiring and devices are by others, 9 tv pathways only, 6 duct detectors, 6 remote test switches 65 nurses call devices as per 2008 nec (west district) install 1 fire alarm strobe and 2 speaker strobes as per nfpa72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: July 31, 2017 | Permit id: 720800 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 18 light fixtures, 2 light switches 4 dimmer switches 6 duplex receptacles, 5 quad receptacles, power for polarizer, amp, power for chiller amp, 6 teledata pathways only, install panel and 6kva transformer that are furnishes by others per 2008 nec (health care) (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: December 23, 2016 | Permit id: 721777 | |||||
SCORE 100 380115 Spruce St Philadelphia Pa 191044110 Remove existing unit sub-station replace with new unit sub. Remove (11) exist panels,(4) sub-dist panels,(6) hp panels,(1) power panel. Replace new installation of new panels ppa & ppd. Install (8) vfds and (9) starters. Install new switchboard sds. Work shown on drawings as per nec 2005. No fire alarm Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 57903 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Furnish and install 19 receptacles,(1)100kva ups,(1)400amps panel,(1)225amp panel,7 tele data pathways (wiring and device are by others)power for (1) fan coil,power for (1)air conditioner compressor and condensor per 2008 nec (health care facility) see log Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: April 30, 2014 | Permit id: 515796 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Furnish and install 16 light fixtures,1 switch,2 dimmer switches,1 receptacles,1-50amp power panel,1-100amp feeder with disconnect switch for chiller and install only siemens 3 kva ups,siemens electronics cabinet per 2008 nec (health care facility) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 515799 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Electrical demo of exisitng kitchen equip; install branch wiring to new equip per2008 nec (health care) new monitor modules for cooking exhaust hoods & shutdown of equipment related to ansul system per nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: April 4, 2017 | Permit id: 747165 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install (120) florescent fixtures, (21) exit signs, (25)switches, (3) 225a rated pnls, (150) recepts. Also included is the following: fire alarm devices, (7) horn strobes, (15) strobes, (1) nac panel.(west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 74770 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install approximately (11) fluorescent fixtures, (1) exit, (7) switches, (17) receptacles and relocate (1) panel in accordance with 2005 nec (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 192200 | |||||
SCORE 100 390715 Spruce St Philadelphia Pa 191044112 Replacement of existing panel boards,replace dormitory receptacles with new tamper resistant receptacles. Replace existing lighting in dorms. New lighting and receptacles in renovated common areas per 2008 nec & nfpa 72(university complex) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: November 13, 2014 | Permit id: 530281 | |||||
SCORE 100 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: April 30, 2014 | Permit id: 510954 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 F&i 710-recpts, 210-sw, 589-lgt fic, 5-floor boxes, 1-elec pnl, 4-bus plugs, 1-4 amp disconnect, 152-f a devices, 99-tele data pathways (teledata wiring & devices are by other as per nec 2008 & nfpa 72 (hospital Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2015 | Permit id: 513724 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovation: add 2 quad receptacles and 1 gfi recetpacle, relamp 11 light fixtures as per 2008 nec (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: December 2, 2016 | Permit id: 734803 | |||||
SCORE 100 38 Spruce St Philadelphia Pa 191044111 Install duplex, quad andgfi recepts, in use covers, co2 panel and sensor, re wire switches as per 2008 nec (west district) Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 551181 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Fit out of existing area 105 outlets, 18-nurse call devices, 15-security devices & 17-fire alarm devices as per nec 2008 & nfpa 72 (health care facility) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 14, 2014 | Permit id: 499664 | |||||
SCORE 100 417 N 8th St Philadelphia Pa 191233907 Demo (103) existing fixtures and replace with new led fiztures. Remove and replace (10) existing receptacles and (15) switches as per 2008 nec. (cc district) Client: Rpm Investments Inc 417 N 8th St Assoc Lp | Client Company: Jmf Development Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 645807 | |||||
SCORE 100 38 Spruce St Philadelphia Pa 191044111 Feed for new exhaust fan; remove reinstall lights as required to facilate new ductwork; misc branch power relocations for ductwork. As per 2008 nec (west district) Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: August 25, 2016 | Permit id: 702427 | |||||
SCORE 100 3905 Spruce St Philadelphia Pa 191044112 Rewire existing elec non-utility meter as per 2008 nec(u of penn univ)(west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 410104 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install approximately (108) florescent fixtures, (35) switches, (80) receptacles, replace (6) panels with new as in accordance with attached drawings as per 2005 nec (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 163040 | |||||
SCORE 100 344155 Walnut St Philadelphia Pa 191043410 Install 350a 480v feeder, mcc & wiring to 2 40hp chilled water pumps. Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 344069 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Replace a total of 16 - 2x2 flourescent fixtures and 4 exit signs Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 48510 | |||||
SCORE 100 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 489075 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Relocate 6-existing recpts, replace 12-existing light fixtures one for one (hospital) as per nec 2008 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: January 3, 2014 | Permit id: 489089 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 In accordance with attached drawings we are disconnecting existing circuits and power poles to the blood bank line and then reconnecting equipment per 2005 nec (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 137676 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Install approx. (100) fluor. Ltg fix, (15) switches, (50) recep, (4) panels, (1) xfmr, (15) spkr strobes, (1) strobe, (12) smokes det & (1) duct det in accordance with nfpa-72 and attached drawings(west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 142761 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Provide and install (24) light fixtures, (10) switches, (24) receptacles and (1) x-ray view box in accordance with 2005 nec (west dist) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 147345 | |||||
SCORE 100 80 Saint Martins Ln Philadelphia Pa 191184101 Throughout-- installation of a new fire alarm system and removal of existing system after new installayion as per 20087 nec and nfpa 72 Client: St Martins In The Fields | Permit type: Electrical permit | Permit status: Completed | Completion date: April 15, 2011 | Permit id: 317099 | |||||
SCORE 100 110 E Roosevelt Blvd Philadelphia Pa 191163961 Retail-rework casework for target store. Add one power pole as per 2008 nec ( Client: Lebanon Pad Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 387881 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Installation of approx new recpts w associated wiring & 13-new lgts fixtures to existing space as per nec 2008 (health care facility) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: July 12, 2013 | Permit id: 468153 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Provide and install conduit and feeders for the customer provided generator as per 2005 nec (west district) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 116468 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 New-45-lgt fixtures, 24-lgt switches, 1-sub-panel, 24-dup recpt, 3-gfi recpt, 3-single recpt, 18-teledata pathways, remove & relocate 4- smoke detectors& 3-speaker strobes as per nec 2008 (hospital) Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 443821 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Renovation existing kitchen replace 2-controllers w 2-new panels, provide 27-recpt new kitchen equip. All lighting, fa, lighting controls are existing to remain (health fac) as per nec 2008 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 447384 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Add receptacles to existing headwalls. Add 4 receptacles at 6 locations per 2008 nec (health care)west district Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Expired | Completion date: March 2, 2016 | Permit id: 671334 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 5 electrical pnl,1-45kva transformer,1-10kv ups,72 fixtures,15 sws,2 occ sensors,6 surface raceway and 177 rec per 2008 nec (health care)install 11 fa strobe lights, speker strobes,18 smokes,1 heat detector and 1 duct smoke detector per nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: July 12, 2016 | Permit id: 671340 | |||||
SCORE 100 728 Sansom St Philadelphia Pa 191063207 Install 12-down lights, 3-exit signs, 12-duplex recepts, emergency light all ckts existing to reuse as per nec 2008 (comm) cc district Client: Tomasetti Richard Tomasetti Eileen | Permit type: Electrical permit | Permit status: Completed | Completion date: September 1, 2015 | Permit id: 599506 | |||||
SCORE 100 90103 Pine St Philadelphia Pa 191076004 Install 2 fluor lt fix, 12 ex signs, sw, 95 recpts, 16 fcu conn`, 82 fa devuces, nurse call devices as per 2008 nec and nfpa-72(health care fac)(cc dist) Client: Pennsylvania Hospital Of | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: October 19, 2012 | Permit id: 392181 | |||||
SCORE 100 900 Walnut St Philadelphia Pa 191075509 Install approx, 2 fluorescent lights fixtures, 144 switches, 3 recepts, lot nurse call system, lot security system 6 transformers and 13 panel as per 2005 nec (cc district) Client: Thomas Jefferson Universi | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 151526 | |||||
SCORE 100 42 Wissahickon Ave Philadelphia Pa 191290000 Temporary party canopy x 45 and x 30. Electrical work includes 20kw generator: 2 manufactured gfci rec. Boxes: par 38 fixtures: misc. Cord connected av equipment, exit signs, and cord protection.(north dist) (5 23 07 to 5 25 07) Client: Salvation Army | Permit type: Electrical permit | Permit status: Completed | Completion date: September 10, 2007 | Permit id: 74764 | |||||
SCORE 100 221 S 34th St Philadelphia Pa 191043803 Demo removal of old 2400v services,demo,removal upgrade of existing 15kv equip,transformers,480v 208v distribution equip,relocation of facp to adj wall,to accommodate new elec rm layout, all work in accordance w 2008 nec nfpa-72(west dist) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: April 18, 2011 | Permit id: 287204 | |||||
SCORE 100 2701 Castor Ave Philadelphia Pa 191345505 Retail-rework casework for target store. Add one power pole as per 2008 nec ( Client: Target Corporation Property Admin | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 387882 | |||||
SCORE 100 1 S 30th St Philadelphia Pa 191043403 Install cat5e data cables max. Length 1 feet per 2008 nec (office space) Client: Sutton James Etal Tr | Client Company: Pete Matthews | Permit type: Electrical permit | Permit status: Expired | Completion date: August 16, 2013 | Permit id: 489649 | |||||
SCORE 100 201 S 32nd St Philadelphia Pa 191044300 Install conduit, wiring, devices for a new fire alarm system as per nfpa72 (west district) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 170323 | |||||
SCORE 100 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 409805 | |||||
SCORE 100 21529 S 33rd St Philadelphia Pa 191043801 Rewire (4) light fixtures and (1) 4 gang switch. Install wire mold to conceal existing exposed wiring. Relocate (6) emergency ballast test switches, clean and replace 57 light fixtures. (west dist). Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 64461 | |||||
SCORE 100 1424 S 21st St Philadelphia Pa 191033100 Replacement of an existing a c unit elec power, 30a split system & the removal and re-installation of the (6) light fixtures in the ceiling below the a c unit, no fire alarm, as per 2005 nec (cc dist) Client: College Of Physicians Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2008 | Permit id: 172801 | |||||
SCORE 100 1424 S 21st St Philadelphia Pa 191033100 Wiring to accomadate a new ahu & condensers, 30amp, 208v, 3 phase circuit to ahu & outdoor nits as per 2005 nec(cc district) Client: College Of Physicians Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2008 | Permit id: 171346 | |||||
SCORE 100 17 S 17th St Philadelphia Pa 191034216 Installing 7 speaker strobe,install one duct detector,install nac panel,all work on existing siemens fire alarm system per 2008 nec & nfpa 72(hotel) Client: Slt Phila Llc St Regis Phila | Client Company: Starwood Hotels & Resorts | Permit type: Electrical permit | Permit status: Completed | Completion date: June 24, 2014 | Permit id: 516454 | |||||
SCORE 100 601 University Ave Philadelphia Pa 191310000 Replace relays and meters in existing mv switchgear, install remote control board and scada monitoring as per 2008 nec (west district) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 316228 | |||||
SCORE 100 29 Island Ave Philadelphia Pa 191532026 Instal 14 data cables cat5e, install 14 voice cables cat3 all cbles under 125 in length (west district) Client: Penrose Property Investor | Client Company: C/o Onyx Equities Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 95964 | |||||
SCORE 100 80034 Walnut St Philadelphia Pa 191075100 Misc . Additional receptacles and lighting added to 9th floor that is already fit out for intended applications as per nec 2008 cc district Client: Liberty Parkway 8th & Wal | Permit type: Electrical permit | Permit status: Completed | Completion date: November 2, 2015 | Permit id: 645804 | |||||
SCORE 100 1 Citizens Bank Way Philadelphia Pa 191480000 Change lamping in existing sign to led (qty 2) per 2008 nec (stadium) Client: City Of Phila | Client Company: The Phillies | Permit type: Electrical permit | Permit status: Expired | Completion date: March 9, 2017 | Permit id: 765597 | |||||
SCORE 100 215458 Stenton Ave Philadelphia Pa 191380000 Install temp 100amp electric service for construction site, service will be active fo 2 months 10 27 08 to 1 15 09 as per 2005 nec (north district) Client: Wm Stenton Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 185057 | |||||
SCORE 100 62535 E Wister St Philadelphia Pa 191440000 Install 67 new ligh fixtures, 15 duplex recepts, 2 gfi recepts as per 2005 nec (north district) Client: La Salle University | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 169672 | |||||
SCORE 100 62535 E Wister St Philadelphia Pa 191440000 Install 1 pull station, 5 smoke detectors, 3 horn strobes and all cable fplp as per nfpa72 (north district) Client: La Salle University | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 189478 | |||||
SCORE 100 2 S 13th St Philadelphia Pa 191075615 Install two new circuits for two 1 2 hp meters per 2008 nec (commercial) Client: The Lenox Condominium | Permit type: Electrical permit | Permit status: Completed | Completion date: March 26, 2014 | Permit id: 462033 | |||||
SCORE 100 1 Crescent Dr Philadelphia Pa 191120000 Install approx 5 fluorescent lights fixtures, switches, 2 recepts, 13 pnaels and 1 transformer as per 2005 nec (south district) Client: L S One Crescent Drive Lp | Client Company: Liberty Property/synterra | Permit type: Electrical permit | Permit status: Completed | Completion date: December 10, 2009 | Permit id: 197781 | |||||
SCORE 100 1 Crescent Dr Philadelphia Pa 191120000 Office-provide & install 21 floor boxes before concrete pour as per 2008 nec no electrical wiring is to be done at this time Client: L S One Crescent Drive Lp | Client Company: Liberty Property/synterra | Permit type: Electrical permit | Permit status: Expired | Completion date: January 27, 2012 | Permit id: 380114 | |||||
SCORE 100 1 Crescent Dr Philadelphia Pa 191120000 Install approx (175) fluor fixtures, (12) exits, (24) occu sensors, (25) switches, (180) receptacles, (4) panels, (6) xfmr, (18) horn strobes, (7) strobes in accordance with attached drawings. In accordance with 2008 nec Client: L S One Crescent Drive Lp | Client Company: Liberty Property/synterra | Permit type: Electrical permit | Permit status: Completed | Completion date: October 19, 2010 | Permit id: 280349 | |||||
SCORE 100 7 S Juniper St Philadelphia Pa 191472570 Additional parking space,install 3 new parking lots poles luminaires,prove raceway and wire for pole and electric gates,provide race way for security access as per 2008 nec Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 308839 | |||||
SCORE 100 173739 Chestnut St Philadelphia Pa 191034115 Install new cat 5e data and voice cables for cash wrap area per 2008 nec Permit type: Electrical permit | Permit status: Expired | Completion date: August 10, 2012 | Permit id: 417734 | |||||
SCORE 100 2300r Oregon Ave Philadelphia Pa 191454129 Retail-rework casework for target store. Add one power pole as per 2008 nec ( Client: Cedar Quartermaster Iii L | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 387884 | |||||
SCORE 100 22 Benjamin Franklin Pkwy Philadelphia Pa 191030000 Connect generator to (1) 15 x 15 tent, (1) 16 x 16 tent, and (1) broadcast trailer. Gen. Tents, tent lighting, emer. Lts, exit lits, and trailer proved by others. (for 5 21; tear down on 5 22) total sq. Ft. = 830. (center city dist) Client: City Of Phila | Client Company: Municipal Services Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: August 8, 2007 | Permit id: 76765 | |||||
SCORE 100 36 Market St Philadelphia Pa 191043147 Install 12-duplex recpt, 10-box & string for lv cable, 2-stand alone nurse call system & relocate 4-light fixtures as per nec 2008 (office bldg) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 447390 | |||||
SCORE 100 555557 Ridge Ave Philadelphia Pa 191282727 Install new fa system in accordance with nfpa-72(storage bldg)(north dist) Client: Stan The Man Investments | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 442029 | |||||
SCORE 100 18 Lombard St Philadelphia Pa 191461400 Install approx fluorescent fixtures, 2 exit signs, 12 switches, recepts, 1 - 200amp panel as per 2005 nec(cc district)fire alarm devices as per nfpa72 Client: Trustees Of The University Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: March 6, 2009 | Permit id: 180490 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Provide install approx (350)flourescent lts fixs,(100)sws, (265)recepts,(8) site ltg fixtures & (8) panels along with (40) nurse call devices (128) fire alarm devices in accordance with nfpa-72 (east dist) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2012 | Permit id: 362237 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Amend ap # 509979 to add fire alarm system , 7 smoke detectors, 7 horn strobes and new head end fire alarm panel as per nfpa72 (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Administrative permit | Permit status: Completed | Completion date: February 26, 2016 | Permit id: 518984 | |||||
SCORE 100 345 N 12th St Philadelphia Pa 191071213 Install new light and receptacles on 2nd and 3rd floor apartments,install new electric panels from existing in basement and install new fire alarm devices per 2008 nec & nfpa 72 (mixed use) Client: Shelly Real Estate Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 530284 | |||||
SCORE 100 216 Paoli Ave Philadelphia Pa 191284340 Install 100amp 480volt feeder,install 1 amp 4 volt disconnect,relocate existing ats and generator,install new panel and circuits,install emon demon meter,install 1 switch and 4 lights per 2008 nec (radio wave transmission facility) Client: American Tower L P | Permit type: Electrical permit | Permit status: Expired | Completion date: February 6, 2014 | Permit id: 516453 | |||||
SCORE 100 202628 Spring Garden St Philadelphia Pa 191303805 Renovation of existing space to a new apt on the 1st floor & basement, new recepts, switches, light fixtures & new heat pump, extending branch wiring from existing panel & meter as per 2008 nec (apt bldg) Client: Altenhofen David W Buchman Mariette J | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 427415 | |||||
SCORE 100 615 Chestnut St Philadelphia Pa 191064404 Install new fire alarm system on floors listed basement 1st four levels of parking,6-14 floors of tenant space per 2008 nec & nfpa 72 (office space) Permit type: Electrical permit | Permit status: Completed | Completion date: October 28, 2015 | Permit id: 548671 | |||||
SCORE 100 615 N Broad St Philadelphia Pa 19123 Fa,lighting,lighting controls,branch wiring,power to hvac equip,phone and data work,distribution equipment,400amp service,temp power and lighting,power to job trailers,electrical demo per 2008 nec & nfpa (place of worship) Permit type: Electrical permit | Permit status: Expired | Completion date: April 7, 2014 | Permit id: 523809 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Surgical fitout consisting of 6 operation rooms and pre and post opt care areas new main distribution panel and branch panel per 2008 nec & nfpa 72 (health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 450651 | |||||
SCORE 100 450838 Chestnut St Philadelphia Pa 191393608 New security and closed circuit television system including: cameras, recorders, card readers, panic buttons, door contacts, electric locks, audible horns and emergency pull stations as per nec 2005 Permit type: Electrical permit | Permit status: Completed | Completion date: August 13, 2007 | Permit id: 58182 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Hospital space that is currently shell space this space shall be fit out with receptacles, lighting, fire alarm and nurse call per 2008 nec (health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 450649 | |||||
SCORE 100 39 Delancey St Philadelphia Pa 191044107 New 15kv med voltage switchgear,new 4 volt double ended substations,new 208 volt double ended substation,new power distribution to new hvac equip,temp support reinstallation of existing lighting per 2008 nec (university complex)new fa duct detectors for new hvac units per nfpa 72 Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: February 3, 2016 | Permit id: 664370 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Install 2 tamper switches and 2 flow switches. (fa) (east dist) Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Completed | Completion date: August 13, 2007 | Permit id: 60787 | |||||
SCORE 100 Client: Paulaski Re Partners Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 334269 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 One floor addition for radiation therapy. Includes 480v & 208v panels lighting,general power. Power and connections for specialized varian true beam medical equipment per 2008 nec. Emergency lighting per article 700. 12(f) of the 2008 nec. Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2014 | Permit id: 491423 | |||||
SCORE 100 3101 Chestnut St Philadelphia Pa 191042816 1 branch panel, 55 lt fxts, 8 sws, recepts, 3 furniture feeds, wiremold, 6 pathways only for teledata wiring by others. (west dist) Client: Rexel Institute Of Art & Science | Permit type: Electrical permit | Permit status: Completed | Completion date: March 19, 2009 | Permit id: 145655 | |||||
SCORE 100 16 Market St Philadelphia Pa 191034201 Install 2 transformers, install 1 squared disconnect breaker, install one transmitter switch, install one meter socket, install new feeder. No fire alarm work. Seco # 93 (cc dist) Client: Phila Liberty Pla E Lp | Client Company: Cushman Wakefield Of Pa | Permit type: Electrical permit | Permit status: Completed | Completion date: October 8, 2008 | Permit id: 139544 | |||||
SCORE 100 3400 Chestnut St Philadelphia Pa 191043406 Electrical demo & tenant fit out; new lighting & branch power as per nec 2008 west district & fire alarm: relocate existing device & add 11 new devices to existing system as per nfpa 72 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 747166 | |||||
SCORE 100 32 Walnut St Philadelphia Pa 191043400 New lighting and branch power within fit out area and instalation of 8 horn horn strobes and 16 stroes. Tie into existing system as per 2008 nec(green space)(west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: June 6, 2012 | Permit id: 382752 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install 4 smoke detector. Install 2 relay modules, install 3 supervised module as per nfpa72 Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: March 16, 2016 | Permit id: 636215 | |||||
SCORE 100 150139 Market St Philadelphia Pa 191021509 Install 13 drops of cat5e plenum rated cable with a longest run of 125ft as per 2008 nec (cc district) Client: Bri 1866 1515 Market Lp | Permit type: Electrical permit | Permit status: Expired | Completion date: September 22, 2016 | Permit id: 723807 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 9 horn strobe, 6 door held, 1 pull station, 5 tri module as per nfpa72 (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2008 | Permit id: 169654 | |||||
SCORE 100 1718 Locust St Philadelphia Pa 191036107 New 400amp feeder, new panel mdp-2 new 400amp circuit breaker, new panel nlr1, new panel nlr3, new lighting, switches and receptacles per 2008 nec (music school) Client: The Curtis Institute Of Music | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 479567 | |||||
SCORE 100 201 Rouse Blvd Philadelphia Pa 19140 1 facp, 14 pull stations,18 horn strobe (ceiling mtd.),23 horn strobes (wall mtd.),8 duct smokes,27 smoke damper interface modules and 19 smoke detectors per 2008 nec & nfpa 72 (commercial) Permit type: Electrical permit | Permit status: Completed | Completion date: January 6, 2015 | Permit id: 523807 | |||||
SCORE 100 801 Market St Philadelphia Pa 191073109 Install new lights fixtures qty 1663 and install new lighting control panel per 2008 nec (retail) Permit type: Electrical permit | Permit status: Completed | Completion date: September 14, 2017 | Permit id: 765618 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Electrical panels, receptacles, 65 light fixtures, 16 light switches. 4 epo switches, power for 2 linacs, misc. Pathways for linac signal cable as per nec 2008 west district see log Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 644722 | |||||
SCORE 100 232783 Cottman Ave Philadelphia Pa 191491002 Install light fixtures qty 49, install switches, 2, install receptacles qty 19, install feed for a c unit, power for water heater, install electric panel, no fire alarm or security work, job# 9268 (east dist) Client: Centro Np Roosevelt Mall | Permit type: Electrical permit | Permit status: Completed | Completion date: June 26, 2008 | Permit id: 127258 | |||||
SCORE 100 25 Grant Ave Philadelphia Pa 191142306 Install cat6 cables for voice & data. Installation to comply with articles 300. 21, 300. 22 & 8 of the 2008 nec. Client: Ard Grant Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 617330 | |||||
SCORE 100 1955 W Hunting Park Ave Philadelphia Pa 191402827 Install 11 data and voice type cable cat5 ez and install one network cabinet per 2008 nec (retail)north district Permit type: Electrical permit | Permit status: Completed | Completion date: February 23, 2017 | Permit id: 739314 | |||||
SCORE 100 39 Delancey St Philadelphia Pa 191044107 Replace lt fxts, provide branch crt power for 2 sets of motorized doors, 1 cage wash, 1 roof unit. Relocate 1 branch panel board. (west dist) Client: The Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 119231 | |||||
SCORE 100 370115 Chestnut St Philadelphia Pa 191043104 Installation of new facp and annunciator with interface to existing system. Conduit riser to support future work on fls, new wiring 12 dry standpipe devices, to support dry standpipe installation.(west dist) Client: Nternational House | Permit type: Electrical permit | Permit status: Completed | Completion date: March 17, 2011 | Permit id: 150635 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 1-300kw fly wheel ups, 1 leak detector and 1 epo per 2008 nec (health care)west district Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: May 13, 2016 | Permit id: 683883 | |||||
SCORE 100 180046 Lombard St Philadelphia Pa 191461400 Install approx, 65 fluorescent lights fixtures, 18 switches, 1 recepts, 3 cable tray and 1 - 100amp panel as per 2005 nec(south district) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: October 8, 2008 | Permit id: 151525 | |||||
SCORE 100 40 Monument Rd Philadelphia Pa 191310000 Retail-rework casework for target store. Add one power pole as per 2008 nec Client: Target Corp | Client Company: Prop Devel | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 387880 | |||||
SCORE 100 10 W Lehigh Ave Philadelphia Pa 191331640 Renovation, nstll 235 light fixtures, 1 recepts, 600amp service, 2 - 1000amp panels, 2 - 60amp panels, 2 - 15amp panels as per 2005 nec (north district) install 75 fire alarm devices with fire alarm control panel Client: Managed Care Services Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: June 30, 2010 | Permit id: 247677 | |||||
SCORE 100 515 Osler Cir Philadelphia Pa 191040000 Install cat5e data cables not to exceed 1 each total number of cables 24 seco# 1272 as per 2008 nec (west district) Client: Childrens Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 317664 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Hospital grade recepts (35), hosptial grade recepts gfi (3), lgiht fixtures (29), single pole switches (11), electrical panel (1), no fire alarm on project Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: May 3, 2007 | Permit id: 49329 | |||||
SCORE 100 82 Germantown Ave Philadelphia Pa 191183402 Temp power and lighting, primary service, secondary service, lighting, distribution equipment and branch power as per 2008 nec (north district) install fire alarm system as per nfpa72 Client: Bowman Properties Limited | Permit type: Electrical permit | Permit status: Expired | Completion date: February 4, 2015 | Permit id: 582357 | |||||
SCORE 100 1 Convention Ave Philadelphia Pa 191040000 Provide and install (24) down light fixtures, (20) receptacles, (2) switches, and (3) exit signs in accordance with 2005 nec (west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 148854 | |||||
SCORE 100 615 Chestnut St Philadelphia Pa 191064404 Install relocate 125 cat5e & fiber optic cables on the 15th & 16th floors Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 316838 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Extend new notification and indication branch wiring and devices into new addition from existing hospitals current fire alarm system per 2008 nec &nfpa 72 (health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Expired | Completion date: November 29, 2013 | Permit id: 503283 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Upgrade of existing mri equipment to newer model rework conduits to match new requirements reuse lighting in space add one new 100amp panel for new receptacles and general power per 2008 nec & nfpa 72 (health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2014 | Permit id: 503285 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Install 1-new 1 volt panel, relocation existing transformer, new homeurns & recepts for new kitchen equipment as per nec 2008 (hospital) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: May 6, 2014 | Permit id: 506999 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Furnish and install 3 light fixtures, 1 key switch, 1 timer switche, 2 duplex recepts as per 2008 nec (west district) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: January 13, 2017 | Permit id: 739018 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Install new lighting epo buttons, branch power, 3-power disconnects, owner supplied ups & transformer, 200amp feeder, 6-nurse call devices as per nec 2008 (hospital) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 489076 | |||||
SCORE 100 1575 N 52nd St Philadelphia Pa 191310000 Demolition,install existing lights(33),exit signs (4), emergency wall pack (17), single pole switches (14),duplex hospital grade (25),duplex tamper proof (29), gfi receptacles (12),new transformer (1), all as per 2008 nec (west dist) Client: Southeastern Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 311025 | |||||
SCORE 100 160123 Market St Philadelphia Pa 191032807 Install one duct detector, install one input module. Install two control retry, install eight ceiling speakers as per nfpa 72 cc district Client: Pa-1601 Market Street Lim | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 741109 | |||||
SCORE 100 33 Chestnut St Philadelphia Pa 191043400 New 15kv service to double ended mvsg 4 volt & 2 volt power distribution,branch power & lighting to student rooms & common areas,kitchen equip power,av & security raceway,350kw generator & emergency power distribution,fa sys lightin protection per 2008 nec & nfpa 72 (university) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Expired | Completion date: November 10, 2015 | Permit id: 523805 | |||||
SCORE 100 370115 Chestnut St Philadelphia Pa 191043104 Remove existing dimming equipment; install new dimming equipment. Add 1 new panic station, preset dimming station and low voltage wiring to interface with new dimming board. Re-use existing branch wiring and reconnect existing feeders. (west dist). Client: Nternational House | Permit type: Electrical permit | Permit status: Completed | Completion date: November 16, 2007 | Permit id: 95178 | |||||
SCORE 100 181228 W Cheltenham Ave Philadelphia Pa 191261025 Install 11 drops of cat5e plenum rated cable with a longest run of 225ft as per 2008 nec (north district) Client: Fd Tic Investors Llc Dkschure Investments Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 10, 2016 | Permit id: 723806 | |||||
SCORE 100 220 S 33rd St Philadelphia Pa 191043802 (265) light fixtures, (4) panels installed, (30) branch power to hvac equipment, (2) relocate (2) panels per 2008 nec (university complex)fire alarm devices and existing system per nfpa 72 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2016 | Permit id: 673474 | |||||
SCORE 100 160123 Market St Philadelphia Pa 191032807 Install new light fixtures,occupancy sensors,duplex receptacles,exhaust fan,water heater,1-30kva transformer,1 panel lp-ka,1 panel rpka and 1 emun dmon meter (commercial)cc district Client: Pa-1601 Market Street Lim | Permit type: Electrical permit | Permit status: Completed | Completion date: January 31, 2017 | Permit id: 733852 | |||||
SCORE 100 3400 Chestnut St Philadelphia Pa 191043406 Renovation of existing space 288 light fixtures, 4 light switches, 4 lighting control modules, 99 duplex recetps, 12 gfi recepts, as per 2008 nec (west district) install 34 fire alarm devices as per nfpa72 Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 10, 2012 | Permit id: 391456 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Temporary 150amp feed for temporary mri trailer new convenience receptacles, lighting and unit heater will be install in the hallway leading to the mri trailer fire alarm pull station and smoke detectors per 2008 nec & nfpa 72(health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 483359 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 4 lighting fixtures,1 receptacles quad,1-sp switches,2 push plates,9 devices relocation,security 2 camera,1 card reader,2 push button and tele data box per 2008 nec (health care)fire alarm 2 smoke detectors,2 remote test switches,1 strobe,1 control module,1 device relocation per nfpa 72 Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 826149 | |||||
SCORE 100 20 Hamilton St Philadelphia Pa 191303820 Install cat5e voice data cables. Longest run 1 feet. Installation to comply with articles 300. 21, 300. 22 & 8 of the 2008 nec. Client: Philadelphia Authority Forodin Market Partners | Permit type: Electrical permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 592579 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Installation of 25 receptacles, 8 switches, fluor light fixtures, including exit signs connected to existing 2 amp panel, remove fire alarm devices for cosmetic changes and replace in existing locations. Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 22413 | |||||
SCORE 100 1718 Locust St Philadelphia Pa 191036107 1 facp, 1 heat detector, 6 smoke detectors & 9 fire alarm modules. Client: The Curtis Institute Of Music | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 490983 | |||||
SCORE 100 3401 Civic Center Blvd Philadelphia Pa 191044302 Install cat 5e cable & nurse call system & devices as shown on attached drawings. Client: Childrens Hospital Of Philadelphia | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 171347 | |||||
SCORE 100 201 Rouse Blvd Philadelphia Pa 19140 Incoming service from dte 1500kv pad mtd transformed for bldg core and sheel, service includes 2000a mp 480v mdp, 800a busduct riser, 5 house panels, 2 transformers, and 1 - 30kw generator, 196 lt fixtures, 29 site ltg on poles, recepts, 26 switches, em lts, 14 exits, motor conn to 3 rtus, 1 fp and jp, cuhs, 4 ewc, 2 elecators, 1 atc apnel, 128 toilet rm sensors for plumbing 9 fans, 3 door contacts, empty conduit for incoming telepone and empty conduit risers for telephone as per 2008 nec (north district) Permit type: Electrical permit | Permit status: Completed | Completion date: January 6, 2015 | Permit id: 506148 | |||||
SCORE 100 2034 Mascher St Philadelphia Pa 19122 Install new kitchen circuits,replace existing panel with new panel,install new lights qty 15,install 2 exit signs and install new switching per 2008 nec (commercial) Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 516449 | |||||
SCORE 100 24 W Hunting Park Ave Philadelphia Pa 191291302 Install 5 furniture feeds, install 1 single pole switch, install 23 lights fixtures, install 1 3c kva transformer,install 2 electric panels, install 1 generator, as per 2008 nec, commercial warehouse Client: Hunting Fox Associates Ii | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2012 | Permit id: 370616 | |||||
SCORE 100 2034 Mascher St Philadelphia Pa 19122 Install f a panel, 1-horn strobe, 3-heat detectors, 1-remote annunciator, 2-smoke detectors, 2-module & 1-pull station as per nec & nfpa 72 Permit type: Electrical permit | Permit status: Completed | Completion date: November 24, 2014 | Permit id: 534735 | |||||
SCORE 100 3401 Curie Blvd Philadelphia Pa 191040000 School-3 sub panels,3-75kva transformers,301 light fixtures, exit lights,63 light sw,3 recepts,8 gfi recepts,1 lighting control panel,37 fire alarm as per 2008 nec and nfpa72 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: September 18, 2012 | Permit id: 392464 | |||||
SCORE 100 1 Convention Ave Philadelphia Pa 191040000 Install (12) receptacles, (3) tele jacks, (2) nurse call pull cords and (2) nurse call dome light, in accordance with attached drawings, per 2005 nec (west dist) Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: June 26, 2008 | Permit id: 133242 | |||||
SCORE 100 641735 Harbison Ave Philadelphia Pa 191493037 Install 12 cat 5e data cable for pos equipment, longest length 100, job #9257x15 as per 2005 nec,(east dist) Client: Kfc Us Properties Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: June 26, 2008 | Permit id: 147344 | |||||
SCORE 100 82 Germantown Ave Philadelphia Pa 191183402 Installation of fire alarm as per nfpa 72 for fresh market fitout. Main electrical permit for project is permit #628130. Client: Bowman Properties Limited | Permit type: Electrical permit | Permit status: Expired | Completion date: November 16, 2015 | Permit id: 645801 | |||||
SCORE 100 240214 Market St Philadelphia Pa 191033009 Fire alarm, add 1 pull station , 2 av, 2 strobes, electrical install 61 lights, 32 switches, 1 panel - 100amp , 1 photo cell, 1 time clock, 62 recepts, 45 wire mold, power for grinder, hot water heater, cabinet heater, 5 heat pumps Permit type: Electrical permit | Permit status: Completed | Completion date: August 13, 2007 | Permit id: 47482 | |||||
SCORE 100 3520 Market St Philadelphia Pa 191043303 Install approximately 3 light fixtures, 1 switches, 3 receptacles, 5 panels & 2 transformers. Client: Mref Ii 35 Market Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2008 | Permit id: 159665 | |||||
SCORE 100 34 Market St Philadelphia Pa 191043306 Install 2 pdus, 800a panel, 1200a panel, 200a feeder, 800a feeder & fire suppression system. Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 241744 | |||||
SCORE 100 352135 Market St Philadelphia Pa 191043302 Installation of the following 8 flourescent fxts, 1 em batt unit, 1 sw, recepts, 3 mech conn cable tray, 2 elec panels, (1) 45 kva transformer. (west dist) Client: Hcp 3535 Market Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 91547 | |||||
SCORE 100 90737 Market St Philadelphia Pa 191073110 Install 2 horn strobe, facp, smoke detector, 1 pull station, 1 relay module, seco #1098, all work using fplp cable as per nfpa-72 (cc dist) Client: Phila Redevelopment Authority | Client Company: Phila Redevelopment Auth | Permit type: Electrical permit | Permit status: Completed | Completion date: September 13, 2010 | Permit id: 295092 | |||||
SCORE 100 36 Pine St Philadelphia Pa 191040000 Replace 2 existing electric meters as per 2008 nec(school)(west dist) Client: Trustees Of The U Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 406248 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Install new feeder for new hvac equipment. Install power for uv lighting reefed humidifier circuits (health care) Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Expired | Completion date: April 4, 2017 | Permit id: 765604 | |||||
SCORE 100 18 Lombard St Philadelphia Pa 191461400 Provision of raceway as required cable and device installation to facilitate the 6th floor nurse call system upgrade Client: Trustees Of The University Of Penn | Permit type: Electrical permit | Permit status: Active | Completion date: October 3, 2017 | Permit id: 819997 | |||||
SCORE 100 413353 G St Philadelphia Pa 191245117 Install 16 cat 5e data cable plenum rated, longest length 125, as per 2005 nec, (east district) Client: G Street Realty Associate | Permit type: Electrical permit | Permit status: Completed | Completion date: September 24, 2008 | Permit id: 161107 | |||||
SCORE 100 82 Germantown Ave Philadelphia Pa 191183402 Install new lighting, & general power, distribution is existing, power connections to all owner equipment & 3-new panel as per nec 2008 north district Client: Bowman Properties Limited | Permit type: Electrical permit | Permit status: Expired | Completion date: September 1, 2015 | Permit id: 628130 | |||||
SCORE 100 2005 Market St Philadelphia Pa 191031415 Replacement of fountain light fixture, one for one, no new wiring as per 2008 nec (cc dist) Client: Commerce Square Partners | Client Company: Thomas Properties | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2011 | Permit id: 348603 | |||||
SCORE 100 615 Chestnut St Philadelphia Pa 191064404 Install cat6 low voltage cable longest run 275 as per 2005 nec (cc district) Permit type: Electrical permit | Permit status: Completed | Completion date: September 17, 2008 | Permit id: 169650 | |||||
SCORE 100 38 Powelton Ave Philadelphia Pa 191042300 New lighting and receptacles in lab and administrative space per 2008 nec (health care facility)west district install fire alarm per nfpa 72 Client: Presbyterian Medical Centpenn Presbyterian Medical | Permit type: Electrical permit | Permit status: Completed | Completion date: January 18, 2017 | Permit id: 692355 | |||||
SCORE 100 2005 Market St Philadelphia Pa 191031415 Install 125 light fixtures, receptacles, 2 switches in accordance drawings & relocate fire alarm devices. Client: Commerce Square Partners | Client Company: Thomas Properties | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 73706 | |||||
SCORE 100 122533 Locust St Philadelphia Pa 191075414 Install voice data: cat 5e for data & cat 3 cable for voice. Max cable length 150. Client: Afc Locust Realty Associa | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 73700 | |||||
SCORE 100 100032 Chestnut St Philadelphia Pa 191075110 Installation of the following: (135) light fixtures, (3) exit signs, (4) switches, (52) receptacles, (2) pull stations, (10) strobes, (1) heat detector, (2) smoke detectors, (5) speakers, (2) duct detectors, (1) 4 volt panel, (2) 1 - 208 panels, & (2) xfrms Client: Thomas Jefferson Universi | Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2007 | Permit id: 53613 | |||||
SCORE 100 311898 Chestnut St Philadelphia Pa 191042811 Interior alterations to exisitng day care lighting 71 fixtures, 32 switches, 15 occupancy things, 17 tele data, 53 recepts, no fire alarm work at this time Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: August 13, 2007 | Permit id: 47611 | |||||
SCORE 100 2601 Holme Ave Philadelphia Pa 191522007 Install 34 light fixtures, 8 switches & misc. Equipment connections in accordane with attached drawings. Client: New Fhs Hosp Nka Nazarethhospital | Permit type: Electrical permit | Permit status: Completed | Completion date: July 13, 2010 | Permit id: 268103 | |||||
SCORE 100 701 Cathedral Rd Philadelphia Pa 191282106 Install point of sale system, install 8 new cat5e data cable longest run 1 as per 2005 nec (north district) Client: Federal Realty Mgmt Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: January 16, 2009 | Permit id: 169649 | |||||
SCORE 100 1735 Market St Philadelphia Pa 191032921 Provide & install light fixtures, receptacles & 6 switches in accordance with attached drawings. Client: Eqc Nine Penn Center Prop | Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2008 | Permit id: 65428 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install lights, switches, receptacles &feeders to new ct equipment as per nec 2008 north district Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Expired | Completion date: March 16, 2016 | Permit id: 628126 | |||||
SCORE 100 4 Domino Ln Philadelphia Pa 191284302 Install new 100amp 480v service, install 75kva transformer, install new 200amp 120 208v panel, install generator sbo, install feeds to 2 ac units and 2 transmitters Client: Nbc Stations Mgt Inc A Colorado Corp | Permit type: Electrical permit | Permit status: Completed | Completion date: March 18, 2008 | Permit id: 54923 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Install 7-new light fixtures, relocate 30-exist light fixtures, install 7-occ sensors, relocate 3-occ sensor, install 22-duplex recepts, 2-gfi recepts, 12-box & conduit as per nec 2008 health care facility per 2008 nec (health care) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 601040 | |||||
SCORE 100 36 Civic Center Blvd Philadelphia Pa 191040000 Install 200amp temporary power for job site trailer for 6 months with no additional wiring as per 2008 nec (west district) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Active | Completion date: October 17, 2017 | Permit id: 824651 | |||||
SCORE 100 770098 City Ave Philadelphia Pa 191512001 Install new voice and data cables cat5e max lenght 125 total number cables (16) per 2008 nec (retail)west district Client: City Line Shopping Centershooster Prop Inc | Client Company: Us Retail Partners Lt Ptn | Permit type: Electrical permit | Permit status: Expired | Completion date: July 12, 2016 | Permit id: 706673 | |||||
SCORE 100 555557 Ridge Ave Philadelphia Pa 191282727 Install elec servie, dist panels, branch circs and lighting as per 2008 nec(commercial retail space)(north dist) Client: Stan The Man Investments | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 414488 | |||||
SCORE 100 99 Frankford Ave Philadelphia Pa 191141905 Install 2 coax cable for satellite dish on roof (east dist) Client: Ls Morrell Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 18, 2007 | Permit id: 84709 | |||||
SCORE 100 641735 Harbison Ave Philadelphia Pa 191493037 Install 12 cat 5e data cable for pos equipment, longest length 100, job #9257x15 as per 2005 nec, 6417-35 harbison ave, (east dist) Client: Kfc Us Properties Inc | Permit type: Electrical permit | Permit status: Expired | Completion date: April 23, 2008 | Permit id: 147342 | |||||
SCORE 100 180121 Market St Philadelphia Pa 191032924 Install cat5e cables for voice & data. Installation to comply with articles 300. 21, 300. 22 & 8 of the 2008 nec. Client: Ten Penn Center Associate | Permit type: Electrical permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 599266 | |||||
SCORE 100 36 Pine St Philadelphia Pa 191040000 Installation of new dual 15kv service switch, transformer, 40 ampere, 208 volt, 3-phase, mdp and distribution to 4 - 8 amp, 208 volt, 3 phase panels (west dist) Client: Trustees Of The U Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 118994 | |||||
SCORE 100 4900 Frankford Ave Philadelphia Pa 191242618 2 pull stations, two horn strobes, 2 smoke detectors, 3 relay modules, all work installed with fplp cable seco #1529 as per nfpa 72 (hospital) Client: Frankford Hospital Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: December 15, 2011 | Permit id: 374931 | |||||
SCORE 100 3200 Chestnut St Philadelphia Pa 191043164 School-remove & reinstall 6 exit lights for new finishes;remove 3 chandeliers & reuse circuits for led lights ;install 6 heaters as per 2008 nec (west district) Client: Rexel University | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 375133 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 1)install new light fixtures (180) 2) install new switching 3) install duplex receptacle (89) 4) electric panels (2) seco # 98 as per 2005 nec (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 243161 | |||||
SCORE 100 141222 Fairmount Ave Philadelphia Pa 191302908 Install new light fixtures install 12 occupancy sensors install two exit signs install 18 duplex receptacles and 11 hospital grade duplex receptacles per 2008 ne (health care facility) Client: Elaware Valley Communityhealth Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2013 | Permit id: 467008 | |||||
SCORE 100 99 Frankford Ave Philadelphia Pa 191141905 Install 15 cat 5e voice and data cables as per 2008 nec(shopping center)(east dist) Client: Ls Morrell Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 401426 | |||||
SCORE 100 40 Locust St Philadelphia Pa 191043507 Healthcare facility-provide power for 2 new exhauset fans. Provide 2 vfds,2 service disconnects & 1 bus duct switch for above work. Pr 1 gfi receptacle as per 2008 nec (west district) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 382529 | |||||
SCORE 100 Client: Passyunk Avenue Revitaliz | Permit type: Electrical permit | Permit status: Completed | Completion date: October 29, 2015 | Permit id: 623579 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Install the following: (5) smoke detectors, (7) pull stations, (20) chimes strobes, (16) strobes, (70) duct det, and (10) door holders in accordance with attached drawings. Please refer to attached permit. (east dist). Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 93828 | |||||
SCORE 100 16 Market St Philadelphia Pa 191034201 Install cat5e low voltage cable for boice and data, total of 37 cables, longest run 185 as per 2005 nec (cc district) Client: Phila Liberty Pla E Lp | Client Company: Cushman Wakefield Of Pa | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 140219 | |||||
SCORE 100 310016 Market St Philadelphia Pa 191042803 Provide new wiring, gasketed receptacles, clean room lighting to existing space to be renovated. One new amp panel. Fire alarm devices and wiring are to be demoed and reworked per 2008 nec & nfpa 72(university) Client: Rexel University | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 470478 | |||||
SCORE 100 90737 Market St Philadelphia Pa 191073110 (7) new electric panels, (2) new transformers, (7) new feeders, (27) duplex receptacles, equipment circuits (35), uau boxes (8), new light fixtures (28), as per 2008 nec (cc dist) Client: Phila Redevelopment Authority | Client Company: Phila Redevelopment Auth | Permit type: Electrical permit | Permit status: Completed | Completion date: September 13, 2010 | Permit id: 286854 | |||||
SCORE 100 2006 Chestnut St Philadelphia Pa 191034411 Install 2 pull stations, 1 smoke detector, 4 strobes, 2 horn strobes, 1 annunciator & 1 facp. Client: Agas Holdings Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 244118 | |||||
SCORE 100 160028 S Christopher Columbus Blvd Philadelphia Pa 191481406 Install circuit for level 3 changing station, install circuit breakers, step up transfomer and disconnect and changing station as per 2008 nec (south district) Client: P A I D Southport Plaza Assoc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 522777 | |||||
SCORE 100 90737 Market St Philadelphia Pa 191073110 Install & duplex receptacles install 4 gfi receptacle install 5 single pole switches install one exit sign install 9 light fixtures install 2 emergency lights per 2008 nec (commercial) Client: Phila Redevelopment Authority | Client Company: Phila Redevelopment Auth | Permit type: Electrical permit | Permit status: Completed | Completion date: April 13, 2013 | Permit id: 444936 | |||||
SCORE 100 2601 Holme Ave Philadelphia Pa 191522007 Addition of lobby smoke detectors, heat detectors and monitors to compliment elevator upgrades in accordance with attached plans and applicable as per 2008 nec,nfpa-72 Client: New Fhs Hosp Nka Nazarethhospital | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 361698 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 Maintenance replace lamps, ballasts, to dimmable outlets, etc, clean up after construction turn over as per 2005 nec (west district) time and material only Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: April 26, 2010 | Permit id: 196778 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Provide generator backup for the ups system,remove existing emergency feed for mob building,refeed mob emergency power from switchboard,ssbd(existing switchboard w existing 400amp breaker) as per 2008 nec (east district) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Expired | Completion date: February 4, 2015 | Permit id: 583503 | |||||
SCORE 100 100119 Market St Philadelphia Pa 191073003 Demolition- install 61 light fixtures, panel, transformer, duplex recept. - 5 power poles - 2 plug mcd-28 doorbell sys,as per 2005 nec, no fa work, (cc dist) Client: Philadelphia Redevelopmen | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 182538 | |||||
SCORE 100 S 16th St Philadelphia Pa 191022523 Install light fixtures, switches, receptacles, poke-thrus, mechanical equipment connections & relocate existing fire alarm devices. Client: Candell Alan J Fliegelman Theresa | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2010 | Permit id: 285023 | |||||
SCORE 100 Client: Southeastern Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: January 20, 2011 | Permit id: 316600 | |||||
SCORE 100 3401 Chestnut St Philadelphia Pa 191043300 Install 15 new cat 5e cables for cash wrap area per 2008 nec (commercial) Client: Trustees U Of P | Client Company: Jll | Permit type: Electrical permit | Permit status: Completed | Completion date: September 18, 2012 | Permit id: 421934 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 To amend electric permit#651983 adding power only for (5) fm-2 panels for mdf and idf rooms as per 2008 nec (middle atlantic) Client: Philadelphia Healthcare | Permit type: Administrative permit | Permit status: Completed | Completion date: October 24, 2016 | Permit id: 716287 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Installation of new head end equipment to provide fire alarm protection to cancer treatment center of america new corner stone expansion. This system will also cover penthouse coverage of fire alarm per 2008 nec & nfpa 72 (health care facility) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: September 10, 2013 | Permit id: 470474 | |||||
SCORE 100 311898 Chestnut St Philadelphia Pa 191042811 Fire alarm system. 14 smoke dets, 4 horn strobes, 1 strobe as per nec 2005 Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2007 | Permit id: 58181 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 150a power conditioner 60amp control panel 11 down lights 2-dimmer switches 4 4x4 lighting panels 1-lights sw 2- door switch 3-data box and stub 3 duplex recept nurse call relocate ex device fa existing to remain 22 epo switch Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Active | Completion date: September 8, 2017 | Permit id: 811917 | |||||
SCORE 100 2801 Grant Ave Philadelphia Pa 191141007 Install approx. (218) fluor. Ltg fixs, (14) exits, (32) switches, (146) receptacles, (3) elec panel & (1) disconnect switches, in accordance with attached drawings and in accordance with 2005 nec (east dist) Client: S3 2801 Grant Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 216669 | |||||
SCORE 100 615 Chestnut St Philadelphia Pa 191064404 Wet standpipe conversion, 2 pressure switches, 1 tamper, 4 riser control valves, 2 roof manifold valves, 5 diesel fire pump monitor points, 6 flow switches, 6 tamper switches, 1 heat trace cabling, a 3 phase 20amp jockey pump circuit as per 2005 nec (cc district) Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2009 | Permit id: 238186 | |||||
SCORE 100 1835 Market St Philadelphia Pa 191032924 Install 16 cat5e cables in office area, longest length 125 feet, seco job#9381, as per 2005 nec (cc dist) Client: Ng 1835 Market Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: June 26, 2008 | Permit id: 148851 | |||||
SCORE 100 2 S 17th St Philadelphia Pa 19103 New dedicated elevator feeder, machine room,pit lights and branch power, misc feeds to hvac units per 2008 nec (multi family)fire alarm new rear elevator smoke detectors primary, secondary and fire hat recall modules per nfpa 72 Permit type: Electrical permit | Permit status: Active | Completion date: June 2, 2017 | Permit id: 779086 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Install 4 duplex receptacles, install 2 epu buttons, install door connection, install power 2 ac units, install panel ir hvac, install 25 lights fixtures, new panel feeder, power for phillip equipment, as per 2008 nec, health center Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Completed | Completion date: February 1, 2012 | Permit id: 370621 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 F & i 6-light fixtures, 3-toggle sw, 8-duplex recpts, 4-gfi recpts, 4-tele data pathways only (cable & devices by others) 2-nurses dome lgts & 2-nurse call pull cords as per nec 2008 (health care) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 568226 | |||||
SCORE 100 3401 Curie Blvd Philadelphia Pa 191040000 Demolition & temporary lights & receptacles.(06 07 thru 02 08) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 85086 | |||||
SCORE 100 1575 N 52nd St Philadelphia Pa 191310000 Install eight (8) low voltage cables for pos system cable type cat5e, maximum length 1 seco job #9431, as per 2005 nec article 300. 21. (west dist) Client: Southeastern Pennsylvania | Permit type: Electrical permit | Permit status: Completed | Completion date: December 1, 2009 | Permit id: 158988 | |||||
SCORE 100 16 Locust St Philadelphia Pa 191036305 Install 1-f a panel, 9-smoke detectors, 5-pull stations, 16-horn strobes, 17-strobe only, 1-heat detectors, all wiring, install w type fpxp cable as per nec 2008 & nfpa 72 office school (will fax contract over as per art) Client: Curtis Institute Of Music | Permit type: Electrical permit | Permit status: Completed | Completion date: April 30, 2014 | Permit id: 489077 | |||||
SCORE 100 3501 Curie Blvd Philadelphia Pa 191040000 Install new f a system, integrate w exist system, install new wiring & devices floor by floor, bring new devices onlne & remove exist sys device remove exist when complete as per nec 2008 & nfpa (labs & offices) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 524571 | |||||
SCORE 100 3400 Chestnut St Philadelphia Pa 191043406 Replace 2 existing electric meters. Rewire 1 existing meter as per nec 2008 school basement Client: Trustees Of The Universit | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 408239 | |||||
SCORE 100 100834 Locust St Philadelphia Pa 191075770 Install 4 speaker strobe devices to existing system as per nfpa72 (cc district) Client: Thomas Jefferson University | Client Company: Treasurers Office | Permit type: Electrical permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 636216 | |||||
SCORE 100 40 Locust St Philadelphia Pa 191043507 Install new lighting,branch power,lighting controls,electrical demo,add 4 horn strobes to existing f a system temporary power and lighting per 208 nec & nfpa 72(dental school) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 529765 | |||||
SCORE 100 40 Locust St Philadelphia Pa 191043507 Demo of existing ahu wiring, panel relocation 2 new vfd 7 industrial lights duct detectors 2 strobes to existing system & damper power and interface controls per 2008 nec & nfpa 72 (dental school) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 475247 | |||||
SCORE 100 3812 Walnut St Philadelphia Pa 191043605 Addition of , transfer switch, 150a 3 phase panel, 100a 3 phase panel, 10kw ups system, wire nema 4x encloseure with cam lock connectors, portable 40kw tier 4 diesel generator & so cables with cam lock connectors as per 2008 nec (west district) Permit type: Electrical permit | Permit status: Expired | Completion date: June 6, 2016 | Permit id: 694442 | |||||
SCORE 100 16 Locust St Philadelphia Pa 191036305 Install new lighting fixtures qty 18 install new exit signs qty 19 install new switches and sensor qty 78 install new duplex and gfi receptacles qty 36 install box and string for low voltage cable qty 24 install new panel qty 3 per 2008 nec. Client: Curtis Institute Of Music | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 484517 | |||||
SCORE 100 200 W Lehigh Ave Philadelphia Pa 191333424 Install point of sale system, install 8 new cat5e data cable longest run 1 as per 2005 nec (north district) Client: Corp Mc Donalds | Client Company: 0451 Mc Donalds Corp 037 | Permit type: Electrical permit | Permit status: Completed | Completion date: January 8, 2009 | Permit id: 169651 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Remove and extend 21 duplex receptacles to new location. Relocate circuit to new hood location as per nec 2008 east district Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Expired | Completion date: August 30, 2016 | Permit id: 711775 | |||||
SCORE 100 100r E Erie Ave Philadelphia Pa 191341009 New construction new 1200amp service entrance switch board installation of lights & receptacles required for medical office bldg installation of site lighting incoming service 277 480v and is transformed down for power requirement on each fl per 2008 nec (medical office bldg) Client: Tenet Healthsystem | Permit type: Electrical permit | Permit status: Completed | Completion date: November 14, 2014 | Permit id: 477226 | |||||
SCORE 100 370115 Chestnut St Philadelphia Pa 191043104 Replacement of medium voltage switch gear,substations,new transformers and power distribution to existing loads per 2008 nec (student housing) Client: Nternational House | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 572406 | |||||
SCORE 100 50 Frankford Ave Philadelphia Pa 191242620 Install 700kw generator, 2 400a ats, 2 400a feeders & concrete pad for generator. Client: The Frankford Hosp Of Phila | Client Company: T F Development | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 282626 | |||||
SCORE 100 100r E Erie Ave Philadelphia Pa 191341009 Installation of new fire alarm system i new building. Install head end notification devices and initiating devices to supplement work on permit 477226 per 2008 nec (medical office bldg) Client: Tenet Healthsystem | Permit type: Electrical permit | Permit status: Completed | Completion date: November 14, 2014 | Permit id: 532679 | |||||
SCORE 100 34 Civic Center Blvd Philadelphia Pa 191044306 F&i light fixtures, 2 dimmers, 1 emergencvy transfer device, 6 deuplex recepts, 3 se3arch pushbuttons, 12 plugmold, 1 card reader, 24" ladder tray, relocate, 2 recepts, 1 radiation monitor, 2 toggle switches and 1 camera as per 2008 nec (west district) Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Expired | Completion date: January 24, 2017 | Permit id: 736893 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install new fire alarm devices on floors 1st,2nd,3rd and 4th, litter building, se job#9300, as per nfpa-72 (north dist) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 149898 | |||||
SCORE 100 540165 Old York Rd Philadelphia Pa 191413025 Install 200amp feeder, 48 fixtures, 6 switches, 15 recepts and 2 smoke detectors as per 2008 nec (north district) Client: Albert Einstein Medical Center | Client Company: Director Of Finance | Permit type: Electrical permit | Permit status: Completed | Completion date: July 31, 2017 | Permit id: 730318 | |||||
SCORE 100 14 John F Kennedy Blvd Philadelphia Pa 191070000 Install new generator, feed to new 800amp electric panel, install 1 gfi recep, 2 lights, 1 - 225 transformer as per 2005 nec (cc district) Client: City Of Phila Dept Of Public Prop | Client Company: Municipal Services Bldg | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 189479 | |||||
SCORE 100 100834 Locust St Philadelphia Pa 191075770 Install new light fixtures, 12 switches, 12 duplex recepts, 4 poke throughs as per 2008 nec (cc district) smokes detectors, and ceiling speakers as per nfpa72 Client: Thomas Jefferson University | Client Company: Treasurers Office | Permit type: Electrical permit | Permit status: Completed | Completion date: November 3, 2015 | Permit id: 582356 | |||||
SCORE 100 120139 Filbert St Philadelphia Pa 191072827 Install 40amp dedicated cir for equiptment as per 2008 nec Client: Filbert Street Associates | Permit type: Electrical permit | Permit status: Completed | Completion date: July 18, 2012 | Permit id: 400120 | |||||
SCORE 100 108 S 40th St Philadelphia Pa 191043017 New 400amp service from peco mh on sidewalk, remove old service, distribute power from new ct cab to branch panel and recetps lights, provice new fire alarm apnel and devices, keep existing system in service till new work is done, then demo old system Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Completed | Completion date: August 8, 2007 | Permit id: 55436 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Addition of (11) 1 amp ats switches to provide back up power to mdf and idf rooms. Addition of one 4 amp panel and 75kva transformers as per nec 2008 east district Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Expired | Completion date: December 21, 2015 | Permit id: 651983 | |||||
SCORE 100 108 Knights Rd Philadelphia Pa 191544208 Installation of all electrical, including 834 light fixtures, 2 switches, 3 recepts, 8 panels and misc conduit and feeders as shown on single line Client: Frankford Hospital Torresdale Division | Permit type: Electrical permit | Permit status: Completed | Completion date: November 23, 2007 | Permit id: 45499 | |||||
SCORE 100 1331 E Wyoming Ave Philadelphia Pa 191243807 Installation of 1. 1kw chp generator for cogeneration,installation of 9-new pump feeds,installation of 1-cooling tower feed as per 2008 nec (east district) Client: Philadelphia Healthcare | Permit type: Electrical permit | Permit status: Completed | Completion date: June 8, 2016 | Permit id: 654673 | |||||
SCORE 100 421 N 13th St Philadelphia Pa 191233608 Provide 289 fixtures,branch cabling for lighting,200amp panel service and 100a panel per 2008 nec (rail park) Permit type: Electrical permit | Permit status: Active | Completion date: June 2, 2017 | Permit id: 779100 | |||||
SCORE 100 370115 Chestnut St Philadelphia Pa 191043104 Install conduit, wire & make connections to a control panel which will operate motirized bleacher type seats as per 2005 nec (west district) Client: Nternational House | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 169652 | |||||
SCORE 100 1 N 30th St Philadelphia Pa 191042814 Install parking lot lights, receptacles, interior lighting, switching, panel & transformer. Client: Amtrak | Permit type: Electrical permit | Permit status: Completed | Completion date: November 13, 2015 | Permit id: 298827 | |||||
SCORE 100 160123 Market St Philadelphia Pa 191032807 New lighting lobby area, install 2 exit signs, install duplex receptacle and all controls lights existing per 2008 nec (office bldg)cc district Client: Pa-1601 Market Street Lim | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 739315 | |||||
SCORE 100 85 Essington Ave Philadelphia Pa 191533701 (3)duplex receptacles, (2)gfi receptacles, (3)teledata outlets, relocate (1)thermostat, pull coax cable for satellite dish (cable furnished by others; satellite dish furnished and installed by others) - all work will be in compliance with the 2008 nec Client: City Of Phila Dept Of Public Prop | Client Company: City Of Phila | Permit type: Electrical permit | Permit status: Completed | Completion date: October 30, 2014 | Permit id: 559760 | |||||
SCORE 100 347 N 12th St Philadelphia Pa 191071213 Replace six existing lights on the outside of the building per 2008 nec (mixed use) Client: Shelly Real Estate Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 469580 | |||||
SCORE 100 650195 E Roosevelt Blvd Philadelphia Pa 191490000 Install 15 cat 5e voice and data cables as per 2008 nec(shopping center)(east dist) Client: Roos Plaza Assoc | Client Company: Assoc Roosevelt Plaza | Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 401427 | |||||
SCORE 100 220 S 33rd St Philadelphia Pa 191043802 Install 23 light fixtures, recepts, 4 coccupancy sensors as per 2008 nec (west district) Client: Trs Univ Of Penn | Permit type: Electrical permit | Permit status: Expired | Completion date: December 12, 2016 | Permit id: 736894 | |||||
SCORE 100 352135 Market St Philadelphia Pa 191043302 Install apr 5 light fixtures, 175 switches, 5 recepts, panels, 2 transformers and fire alarm devices. Fire alarm drawings are not attached and shall be submitted at a later date (west district) Client: Hcp 3535 Market Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: September 22, 2008 | Permit id: 129390 | |||||
SCORE 100 709 E Allegheny Ave Philadelphia Pa 191342404 Existing service 100amp, replace with 100amp service electric cable, meter socket as per nec 2008 east district Client: Zecharia Gabrial | Permit type: Electrical permit | Permit status: Completed | Completion date: September 15, 2016 | Permit id: 711014 | |||||
SCORE 100 Client: Parkway Corporation | Permit type: Electrical permit | Permit status: Completed | Completion date: July 18, 2012 | Permit id: 400121 | |||||
SCORE 100 80008 Arch St Philadelphia Pa 191073100 Install 48 duplex receptacles 6 gfi receptacles 17 switches 11 occupancy sensors 3 exit signs 4 emergency lights 3 power poles 1 exhaust fan 1 water heater 8 baseboard heaters 68 lights per 2008 nec (retail) Client: Philadelphia Parking Auth | Permit type: Electrical permit | Permit status: Completed | Completion date: October 19, 2017 | Permit id: 779079 | |||||
SCORE 100 80008 Arch St Philadelphia Pa 191073100 Install 2 pull stations 2 horn strobe 2 strobe only 1 remote annuniciator 1 facp 2 control modules 4 duct detectors. Client: Philadelphia Parking Auth | Permit type: Electrical permit | Permit status: Active | Completion date: September 25, 2017 | Permit id: 811263 | |||||
SCORE 100 711 E Allegheny Ave Philadelphia Pa 191342404 Replace existing 100amp service feeding bldg. Replace existing receptacles and switches. Replace existing light fixtures per 2008 nec (commercial)east district Client: Zecharia Gabrial | Permit type: Electrical permit | Permit status: Expired | Completion date: November 3, 2016 | Permit id: 723502 | |||||
SCORE 100 82 Germantown Ave Philadelphia Pa 191183402 200amp temporary service wire job trailer per 2008 nec (job site) Client: Bowman Properties Limited | Permit type: Electrical permit | Permit status: Completed | Completion date: November 24, 2014 | Permit id: 558038 | |||||
SCORE 100 4301 Byberry Rd Philadelphia Pa 191540000 Install cat 5e cable for pos equipment, total # of cables (12) only as per 2008 nec (retail) no other work done on this permit Client: Franklin Mills Associates | Client Company: Simon Property Group Inc | Permit type: Electrical permit | Permit status: Expired | Completion date: March 5, 2013 | Permit id: 456939 | |||||
SCORE 100 21 N American St Philadelphia Pa 191221623 Install the following, 7 site light pole fixtures, 13 ext wall pack fixtures, 3 fluor. Fixtures, 8 exits, 6 remote batt. Fixtures, 38 switches, 1 recepts, 1 gen set & 5 panels (east dist) Client: Chaes Food Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: February 15, 2008 | Permit id: 83979 | |||||
SCORE 100 80149 Pine St Philadelphia Pa 191076000 Install 2-new panel, new general power & lighting & associated work required for various lab equipment & new nurse call devices installed as per nec 2008 & install fire alarm as per nfpa 72 Client: Penna Hospital | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 621473 | |||||
SCORE 100 7821 Bartram Ave Philadelphia Pa 191533200 Install cat 6 data cables plenum rated longest run 115 as per 2008 nec (west district) Client: Gateway Business Center L | Permit type: Electrical permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 652950 | |||||
SCORE 100 1515 Arch St Philadelphia Pa 191021508 Install new generator, install 3 alts, install 2-6 amp circuit breakers, install new 6 amp feed from generator and 1 amp feed from generator, new concrete pad, as per 2005 nec (cc dist) Client: Phila Auth & Ind Dev | Client Company: Centre Square West | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 156239 | |||||
SCORE 100 1 S Broad St Philadelphia Pa 191073300 New mdf and adjoining space, 3 elec panels, 8 receptacles, 1 owner supplied kva ups, cable dtray. Power for 2 a c & 1 vav. Replace 58 light fixtures. 4 occupancy sensors, 6 fire alarm devices as per 2008 nec (cc district) Client: Broad One L P | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2010 | Permit id: 282737 | |||||
SCORE 100 23343 S Broad St Philadelphia Pa 191075659 Replace existing light fixtures with new fixtures as per 2005 nec (cc dist) Client: Lobro Associates | Client Company: Jay Barnett | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 126478 | |||||
SCORE 100 23343 S Broad St Philadelphia Pa 191075659 Install 4 fire pump control monitoring points, 1 flow switch, 8 tampers, 1 3-phase 20a 208v jockey pump feeder, 1 15kva transformer & 1 100a panel. Client: Lobro Associates | Client Company: Jay Barnett | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2009 | Permit id: 243760 | |||||
SCORE 100 Client: Spus7 16 Arch Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 304181 | |||||
SCORE 100 180135 N Broad St Philadelphia Pa 191221803 New electrical service (15kv), distribution, emergency generator, lighting, lighting control, emergency lighting, receptacles, power for hvac equipment, raceways only for teledata, security, a v. (east dist) Client: Temple University | Client Company: Director Of Real Estate | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2009 | Permit id: 107042 | |||||
SCORE 100 4301 Byberry Rd Philadelphia Pa 191540000 Install 4 cat 5e data cables for wap and printer and install 1 duplex recept in accordance with 2008 nec(commercial-retail space)(east dist) Client: Franklin Mills Associates | Client Company: Simon Property Group Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: January 29, 2013 | Permit id: 443454 | |||||
SCORE 100 2201 S Broad St Philadelphia Pa 191482916 Install 46 cat6 voice data cables for pos system & voice system. Client: Commerce Bank Pennsylvani | Permit type: Electrical permit | Permit status: Completed | Completion date: January 6, 2015 | Permit id: 572206 | |||||
SCORE 100 113234 Callowhill St Philadelphia Pa 191233710 Install solar panels on roof, 1 utility disconnect, 1 solar combined panel as per 2008 nec (cc dist) office Client: Shelly Bruce D | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2012 | Permit id: 402676 | |||||
SCORE 100 80149 Pine St Philadelphia Pa 191076000 Additional receptacles, lighting and nurse call for heat station. Relocation of 120v panel as per nec 2008 cc district Client: Penna Hospital | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Expired | Completion date: November 16, 2015 | Permit id: 645803 | |||||
SCORE 100 80149 Pine St Philadelphia Pa 191076000 New amp feed to medical equipment. The existing ceiling is to be lowered. Existing lights shall be removed and reinstalled. One new power receptacle shall be installed per 2008 nec (health care) Client: Penna Hospital | Client Company: Penna Hospital | Permit type: Electrical permit | Permit status: Expired | Completion date: October 13, 2015 | Permit id: 642880 | |||||
SCORE 100 1717 Arch St Philadelphia Pa 191032706 Replace existing fixtures with new qty 34 install duplex receptacles qty 8 per 2008 nec (office bldg) Permit type: Electrical permit | Permit status: Expired | Completion date: July 12, 2013 | Permit id: 469581 | |||||
SCORE 100 1 S Broad St Philadelphia Pa 191073300 Install plenum voice data cables for computers & pos equipment. Installation to comply with articles 300. 21 & 8 of the 2008 nec. Client: Broad One L P | Permit type: Electrical permit | Permit status: Completed | Completion date: April 30, 2014 | Permit id: 466985 | |||||
SCORE 100 70115 N Broad St Philadelphia Pa 191232402 Remove existing lighting poles and install lighting poles, 1 photocell nad 1 contactor as per 2005 nec (cc district) Client: Salvation Army Philadelph | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 196779 | |||||
SCORE 100 7422 Bustleton Ave Philadelphia Pa 191524312 Retail-rework casework for target store. Add one power pole as per 2008 nec ( Client: Bustleton Partners | Client Company: Kimco Realty Corp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 387883 | |||||
SCORE 100 2 S Broad St Philadelphia Pa 191023815 Delete (13) receptacles at existing peco bar,install (7) new receptacles to match new equipment, feed new receptacles from new sub panel as per 2008 nec (cc dist) Client: Academy Of Music Of Phila Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: February 18, 2011 | Permit id: 320824 | |||||
SCORE 100 Client: Phila Auth For Industrial Dev | Client Company: Chief Financial Officer | Permit type: Electrical permit | Permit status: Completed | Completion date: July 6, 2012 | Permit id: 400118 | |||||
SCORE 100 23343 S Broad St Philadelphia Pa 191075659 New switchgear and hotel fitout required - new 13 2 kv sub station - distribution panels on each floor - lighting and branch wiring for 48 hotel suites - fire alarm wiring for hotel extension and parking garage - as per plans (2 sets - fire and wiring - 7 pages electrical plans - 24 pages for fire alarm) - as per 2008 nec Client: Lobro Associates | Client Company: Jay Barnett | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2014 | Permit id: 464052 | |||||
SCORE 100 1607 S Broad St Philadelphia Pa 191481003 Install 28 light fixtures, 5 exit signs, 7 switches, power for water heater, power for 1 a c unit & 44 receptacles. Client: Ng Chen Zhen Thi Huynh Thanh | Permit type: Electrical permit | Permit status: Completed | Completion date: December 30, 2015 | Permit id: 564465 | |||||
SCORE 100 36 Civic Center Blvd Philadelphia Pa 191040000 8 story bldg new. New 15kv service panels generation new lighting branch power device as per 2008 nec(west district) new fire alarms system simplex as per nfpa72 Client: Trustees Of The Univ Of Pennsylvania | Permit type: Electrical permit | Permit status: Active | Completion date: December 7, 2017 | Permit id: 808023 | |||||
SCORE 100 34 Spruce St Philadelphia Pa 191044204 Lighting a1 15 a2 24 a35 a4 2 exit 7 os 14 osvm 6 sor 3 branch devices wiremold 25lf duplex recept spec recept connn 6 disconnect sw and conn 30a 6 vav jbox and conn 2 auto door jbox and conn 9 push plate 12 security card reader 5 data box and stub 22ea. Connect to existing panel boards and provide circuit breakers as req 5ea per 2008 nec (health care)install smoke detectors 5ea,av device 11 ea,strobe 1 ea. Nac panel 1ea. Szam 2 ea per nfpa 72 Client: Trs Univ Of Penn | Client Company: Franklin Bldg | Permit type: Electrical permit | Permit status: Active | Completion date: December 14, 2017 | Permit id: 832770 |