QUALITY
ACTIVITY
AVERAGE PROJECT COST
PERMITS VALUATION
PROJECTS PER TOWN:
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 100 Client: My Mai | Permit type: Renovations -interio | Current use: Other | Permit id: E90087 | Parcel: 1600902000 | |||||
SCORE 100 359-365 Adams St Dorchester Ma 02122 This application file for final inspection - two panels already done on previous permit e90087 in addition;install 4 new signs Client: My Mai | Permit type: Electrical | Current use: Comm | Permit id: E102633 | Parcel: 1600902000 | |||||
SCORE 100 359 365 Adams St Dorchester Ma 02122 This application file for final inspection - two panels already done on previous permit e90087 in addition;install 4 new signs Client: My Mai | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E102633 | Parcel: 1600902000 | |||||
SCORE 100 Client: My Mai | Permit type: Renovations -interior nsc | Permit status: Expired | Current use: Other | Permit id: E90087 | Parcel: 1600902000 | |||||
SCORE 100 138 Newbury St Boston Ma 02116 Removing existing electrical wires in walls on first floor store - american apparel Client: Orika 121 Inc | Permit type: Electrical | Current use: Comm | Permit id: E26015 | Parcel: 501314000 | |||||
SCORE 100 359365 Adams St Dorchester Ma 02122 This application file for final inspection - two panels already done on previous permit e90087 in addition;install 4 new signs Client: Sam Perry | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E102633 | Parcel: 1600902000 | |||||
SCORE 100 Client: Sam Perry | Permit type: Renovations -interior nsc | Permit status: Expired | Current use: Other | Permit id: E90087 | Parcel: 1600902000 | |||||
SCORE 100 Client: My Mai | Permit type: Electrical permit | Expiration date: March 30, 2012 | Current use: Other | Permit id: E90087 | Parcel: 1600902000 | |||||
SCORE 100 Client: Sam Perry | Permit type: Electrical permit | Expiration date: March 30, 2012 | Current use: Other | Permit id: E90087 | Parcel: 1600902000 | |||||
SCORE 100 138 Newbury St Boston Ma Removing existing electrical wires in walls on first floor store - american apparel Client: Orika 121 Inc | Permit type: Electrical permit | Expiration date: November 14, 2010 | Current use: Comm | Permit id: E26015 | Parcel: 0501314000 | |||||
SCORE 100 359 365 Adams St Dorchester Ma This application file for final inspection - two panels already done on previous permit e90087 in addition;install 4 new signs Client: My Mai | Permit type: Electrical permit | Expiration date: April 25, 2012 | Current use: Comm | Permit id: E102633 | Parcel: 1600902000 | |||||
SCORE 100 359365 Adams St Dorchester Ma This application file for final inspection - two panels already done on previous permit e90087 in addition;install 4 new signs Client: Sam Perry | Permit type: Electrical permit | Expiration date: April 25, 2012 | Current use: Comm | Permit id: E102633 | Parcel: 1600902000 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21684 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21685 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21686 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21687 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21688 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21691 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21712 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21258 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-23487 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21528 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21529 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21697 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21699 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21701 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21702 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21703 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21704 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21707 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21708 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21709 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21711 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21683 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21530 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21531 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21532 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21533 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-23485 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21706 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21637 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21638 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21256 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21257 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21259 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21260 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21261 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21262 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-23395 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21062 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21063 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21874 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-20878 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-20879 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-21693 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14536 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14563 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14564 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14565 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-10534 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-10634 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14940 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-06-26209 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-18218 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-07219 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-08-01179 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14535 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-95460 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06539 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-95324 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-02352 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06535 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06536 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-04485 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-05106 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-92876 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-10-00015 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-07217 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-93807 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06540 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-93968 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-07220 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06537 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-10-01187 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-95366 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-06538 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-07-14534 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-94881 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-95020 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-07218 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-10-02249 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-08-01014 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-09-95022 | |||||
SCORE 100 Permit type: Permits/plumbing/residential/plumbing | Permit status: Issued | Permit id: Plb-10-04728 | |||||
SCORE 100 3708 156 St S Omaha Ne 68135 Lake zorinsky pump house-1 lochnivar cpn 1800(1800000btu) | address changed from 3808 on 06/08/2010 Permit type: Permits/mechanical/commercial/pressure vessel | Permit status: Issued | Permit id: Mec-10-03794 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-09-93707 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-09-93969 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-15-01309 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-12-02532 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-14-04099 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Pending additional fees | Permit id: Plb-13-03874 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-14-03650 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-14-03556 | |||||
SCORE 100 Permit type: Commercial plumbing | Permit status: Issued | Permit id: Plb-14-04820 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-11-03002 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-11-02269 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-11-03739 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-11-00258 | |||||
SCORE 100 Permit type: Permits/plumbing/commercial/plumbing | Permit status: Issued | Permit id: Plb-10-05930 | |||||
SCORE 100 Permit type: Residential plumbing | Permit status: Issued | Permit id: Plb-13-08414 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-13-01712 | |||||
SCORE 100 Permit status: Issued | Permit id: Plb-12-02607 | |||||
SCORE 100 Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-90000-234 | |||||
SCORE 100 Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-90000-234 | |||||
SCORE 100 13 S 10th St Philadelphia Pa 191475619 Remove all redundant wiring and replace w new at same locations;add gfci,afci required in bedrm,bath and kitchen as per 2008 nec (sfd) Client: Picco Christopher R | Permit type: Electrical permit | Permit status: Expired | Completion date: June 27, 2013 | Permit id: 480320 | |||||
SCORE 100 31 Grant Ave Philadelphia Pa 191142501 Direct replacement of eight (8) light fixtures, direct replacement of four (4) duplex receptacles, install new four (4) gfci counter receptacles, pers 2005 nec (east dist) Client: Buoncristiano Albert Buoncristiano Mary | Permit type: Electrical permit | Permit status: Expired | Completion date: March 7, 2008 | Permit id: 136882 | |||||
SCORE 100 2108 Master St Philadelphia Pa 191210000 2 amp outside service w 2 meter sockets feeding 1 fused disconnect and 1 1 amp circuit main breaker panel w proper grounding throughout Client: Prime Street Holdings Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: February 16, 2007 | Permit id: 50279 | |||||
SCORE 100 1417 Point Breeze Ave Philadelphia Pa 191464521 Install 5 emergency lights, 1 exit sign & 1 remote head. Client: Quillen Minerva | Permit type: Electrical permit | Permit status: Completed | Completion date: September 11, 2009 | Permit id: 212872 | |||||
SCORE 100 6 Reed St Philadelphia Pa 191475812 Install 5-20amp dedicated cir for kitchen,1-30amp 240v for outside a c unit 1-20amp cir for basement laundry (washer-dryer),2-20amp cir for 2nd fl bath (gfci lighting) change 12 circuits f. P panel to circuit seimans w main (100a) Client: Halligan Aileene Cantiello Christian T | Permit type: Electrical permit | Permit status: Completed | Completion date: December 14, 2012 | Permit id: 408642 | |||||
SCORE 100 2108 Master St Philadelphia Pa 191210000 Install 26 receptacles, 8 gfci receptacles, 23 light fixtures, 12 switches & 7 smoke detectors. Client: Prime Street Holdings Lp | Permit type: Electrical permit | Permit status: Expired | Completion date: July 12, 2007 | Permit id: 88919 | |||||
SCORE 100 1746 N 16th St Philadelphia Pa 191213204 Upgrade service to 400amp change 7 meters to vertical w disconnect and proper grounding per 2008 nec Client: Goodheart Harry M | Permit type: Electrical permit | Permit status: Completed | Completion date: April 20, 2013 | Permit id: 412260 | |||||
SCORE 100 7 S Warnock St Philadelphia Pa 191472729 Panel changeover to 24 ckt 100a main upgrade with proper grounding bonding throughout remove redundant wiring & replace in kind, add 4-gfci recpts, install 8-lgts fixtures & 6-recpts as per nec 2008(sfd) Client: Grossman Joshua N Spatacco Nicole M | Permit type: Electrical permit | Permit status: Expired | Completion date: April 24, 2015 | Permit id: 603776 | |||||
SCORE 100 6945 Tulip St Philadelphia Pa 191352019 Remove all redundant wiring in basement, secure all cabling in approved locations, balance load in 1 amp panel, proper grounding throughout, as per 2005 nec, to comply with violation #166847 (east dist) Client: Gatti Natalie H | Permit type: Electrical permit | Permit status: Completed | Completion date: February 25, 2010 | Permit id: 239944 | |||||
SCORE 100 Client: Presley-Belford Darnell Rbelford Terry W | Permit type: Electrical permit | Permit status: Expired | Completion date: November 27, 2015 | Permit id: 654747 | |||||
SCORE 100 9335 Treaty Rd Philadelphia Pa 191143509 Replace existing service meter socket and panel, 2 amp add three outlets one gfi and two light fixtures. Client: Fong Larry C Denise | Permit type: Electrical permit | Permit status: Completed | Completion date: September 20, 2017 | Permit id: 737583 | |||||
SCORE 100 6301 Trotter St Philadelphia Pa 191115841 Cover plates, j box covers, loose fitures, check 200amp service and fuse one 240v circuit property, remove redundant wiring (door bell) change 1 bedroom llight switch as per 2008 nec (east district) Client: Tedesco John Tedesco Janet | Permit type: Electrical permit | Permit status: Expired | Completion date: February 9, 2015 | Permit id: 584528 | |||||
SCORE 100 2057 South St Philadelphia Pa 191461320 Reroute 2-switches & 1-recept to kitche dividing wall, install 2-2-a ckts for basement sump pump & laundry, install new dedicated recept for kitchen refrigerator as per nec 2008 south district Client: Sj Enterprises Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: July 5, 2017 | Permit id: 781489 | |||||
SCORE 100 5637 Stewart St Philadelphia Pa 191313405 Ez electric permit - install 100a panel change over to 24- pane; remove wiring throughout and replace where needed. 14 recessed lights 3 kitchen gfcis add 8 smoke detectors 1 refrigerator and garbage disposal circuits grounding and bonding as per nec 2008. Client: Bsd Ya Llc | Permit type: Electrical permit | Permit status: Active | Completion date: October 26, 2017 | Permit id: 827220 | |||||
SCORE 100 1722 Pine St Philadelphia Pa 191036702 Upgrade electrical service to 600amp,complete rewire of apt 2,partial rewire of apt 3 & 4,bathrooms,kitchens and code upgrade per 2008 nec (multi family) Client: Blau Laura A Thompson Paul A | Permit type: Electrical permit | Permit status: Active | Completion date: July 5, 2017 | Permit id: 776205 | |||||
SCORE 100 66 Tulip St Philadelphia Pa 191352806 Partial rewire of lighting, receptacles & switches per 2008 nec Client: Johnson Lorna A Frizell Richard E | Permit type: Electrical permit | Permit status: Completed | Completion date: April 12, 2011 | Permit id: 305518 | |||||
SCORE 100 2152 N 21st St Philadelphia Pa 191211405 Install 200a service, 4-gang meter socket, 4 100a disconnects, refeed 4 panels & install proper grounding. Client: James Lake | Permit type: Electrical permit | Permit status: Expired | Completion date: January 5, 2009 | Permit id: 188772 | |||||
SCORE 100 18 Delancey Pl Philadelphia Pa 191036607 2 kitchen counter gfci circuits. Redress and balance load in 2 amp panel. 1 laundry lighting circuit and 2 recepts in basement for convenienc use. (cc dist) Client: Scott Ralph M | Permit type: Electrical permit | Permit status: Completed | Completion date: June 28, 2008 | Permit id: 149726 | |||||
SCORE 100 18 Delancey Pl Philadelphia Pa 191036607 Upgrade 200amp service to 3 amp , new meter socket end box, change 100amp main lug panel to 200amp main lug panel, add new 200amp fused disconnect and proper grounding as per ne 2005 (cc district) Client: Scott Ralph M | Permit type: Electrical permit | Permit status: Completed | Completion date: July 2, 2008 | Permit id: 148426 | |||||
SCORE 100 263436 E Cumberland St Philadelphia Pa 191253704 Ugrade srvc to 200a w circ panel, 2 ground rods, install 45 dup recpts, 21 switches, 13 lighting runs(8 circ) supply power for heating & air cond (2) elec hot water (1) emerg lights exit lighted signs as per 2008 nec(east dist) recording studio Client: Studio Crash Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: June 7, 2012 | Permit id: 377631 | |||||
SCORE 100 1124 E Oxford St Philadelphia Pa 191254217 New 1 amp underground svs w circuit panel proper grounding throughout four bedrooms, 3 baths, basement, kitchen and laundry. Single family dwelling row home. As per nec 2005 (east dist) Client: Chiarelli Joao Chiarelli Eliane G | Permit type: Electrical permit | Permit status: Expired | Completion date: July 1, 2008 | Permit id: 141598 | |||||
SCORE 100 133337 N Front St Philadelphia Pa 191224603 Provide electrical construction for 7 studios and 1 office with 4 amp service per 2008 nec. Installation to comply with article 210. 63 of the 2008 nec. Client: Hurwits Michael Hurwits Mamicato | Permit type: Electrical permit | Permit status: Expired | Completion date: June 27, 2013 | Permit id: 470324 | |||||
SCORE 100 225 W Gorgas Ln Philadelphia Pa 191192510 Remove redundant wiring and replace 18 receptacles switches and proper grounding throughout per 2008 nec (sfd) Client: Giannelli Christian A Giannelli Melissa E | Permit type: Electrical permit | Permit status: Completed | Completion date: April 11, 2014 | Permit id: 521063 | |||||
SCORE 100 2336 E Cumberland St Philadelphia Pa 191253125 Remove ungrounded romex & replace with grounded romex 14-2 & 14-3 as per nec 2008 east district (sfd) Client: Lepostollec Michael D Carroll Colleen B | Permit type: Electrical permit | Permit status: Completed | Completion date: November 6, 2015 | Permit id: 603774 | |||||
SCORE 100 1219 E Luzerne St Philadelphia Pa 191245300 Replacement of 6 compressors with new units and wiring, install 7 shop lights in basement, install track lighting and floor light fixtures, replacing old fixtures and all redundant wiring throughout. Move sub-panel in basement.(east dist) Client: Romano Miguelina | Permit type: Electrical permit | Permit status: Expired | Completion date: October 3, 2007 | Permit id: 107020 | |||||
SCORE 100 1537 Pine St Philadelphia Pa 191024623 Install 12 duplex receptacles,2 gfcis,6 light fixtures and 6 switches per 2008 nec (cc district) Client: Raab Claire Goldhammer Jordan | Permit type: Electrical permit | Permit status: Expired | Completion date: January 5, 2016 | Permit id: 661763 | |||||
SCORE 100 1124 Gerritt St Philadelphia Pa 191475604 Rewire duplex, properly ground service, add 12 recessed lights, 5 120v smoke detectors, telephone jacks, catv jacks & arc-fault breakers. Client: Esposito Louis Esposito Colleen | Permit type: Electrical permit | Permit status: Expired | Completion date: April 28, 2009 | Permit id: 212874 | |||||
SCORE 100 1428 Germantown Ave Philadelphia Pa 191223707 Replace in kind 35 receptacles, switches and 12 light fixtures per 2008 nec (art studio) Client: Heyman Laura E Wischmann William John | Permit type: Electrical permit | Permit status: Completed | Completion date: May 1, 2014 | Permit id: 501107 | |||||
SCORE 100 133337 N Front St Philadelphia Pa 191224603 Replace existing 200amp 3phase 240v service upgrade panel to circuit from smaller panel per 2008 nec (commercial) Client: Hurwits Michael Hurwits Mamicato | Permit type: Electrical permit | Permit status: Completed | Completion date: May 4, 2013 | Permit id: 449766 | |||||
SCORE 100 547 W Clearfield St Philadelphia Pa 191332817 Install 3 phase 100a 480v line from existing service to fused disconnect for new equipment (#2 copper conductor in conduit clean up old disconnects and remove redundant wiring)per 2008 nec (auto repair) Permit type: Electrical permit | Permit status: Completed | Completion date: May 1, 2014 | Permit id: 501109 | |||||
SCORE 100 31925 N 11th St Philadelphia Pa 191071305 Replace existing combination exit signs, light fixtures and install 4 baseboard electric heaters. In north fire tower. Repalce 6 existing combination exit signs andadd 4 baseboad electric heaters in west fire tower as per 2008 nec. Client: Weinstein Robert B | Permit type: Electrical permit | Permit status: Active | Completion date: October 23, 2017 | Permit id: 826202 | |||||
SCORE 100 2357 E Huntingdon St Philadelphia Pa 191252338 Install 6 amp dedicated circuits for kitchen, 240v circuit for washer dryer combo & 2 bathroom lighting circuits. Client: Simpson Eric D Simpson Robert | Permit type: Electrical permit | Permit status: Expired | Completion date: August 20, 2010 | Permit id: 230442 | |||||
SCORE 100 122022 Mascher St Philadelphia Pa 191224617 Change 24 light fixtures, secure existing 200amp service new backboard, add 2 counter gfci & 2 bath gfcis, remove redundant wiring add recepts as per 2008 nec (east district) Client: Yaple Matt | Permit type: Electrical permit | Permit status: Expired | Completion date: February 9, 2015 | Permit id: 584527 | |||||
SCORE 100 1825 W Wilt St Philadelphia Pa 191212203 Install (4) amp circuits feeding twenty (20) duplex receptacles, install (18) light fixtures, install (2) circuits for (2) gfci receptacles, per 2005 nec (north dist) Client: Realm Acquisition Concept | Permit type: Electrical permit | Permit status: Expired | Completion date: March 7, 2008 | Permit id: 136880 | |||||
SCORE 100 5545 Locust St Philadelphia Pa 191393940 Replace lighting throughout 1 & 2nd floor with same kind & no additional wiring, fix or repair junctions as per nec 2008 west district Client: League Shawn C League Lauren E | Permit type: Electrical permit | Permit status: Expired | Completion date: August 18, 2016 | Permit id: 703183 | |||||
SCORE 100 2813 W Allegheny Ave Philadelphia Pa 191321231 Install 200a service, proper grounding, 25 receptacles, light fixtures, 4 gfci recetacles, 16 switches & 7 120v smoke detectors. Client: Baldwin Ryan K | Permit type: Electrical permit | Permit status: Completed | Completion date: March 10, 2011 | Permit id: 88926 | |||||
SCORE 100 50105 S Broad St Philadelphia Pa 191471005 Commercial-replace 3 meter sockets & 3 panels with new;add 2nd grounding to cold water supply as per 2008 nec (south district) Client: Patel Sailesh R | Permit type: Electrical permit | Permit status: Completed | Completion date: July 26, 2012 | Permit id: 375222 | |||||
SCORE 100 201953 E Boston St Philadelphia Pa 191250000 Replace 16 ceilign light fixtures (existign wiring). Reconnect exisitng hot water heater. Reconnect (2) wall heaterss in two restrooms.. Install new (2) gfci (2) o. H. Lights (2) exhaust fans. In existing bathrooms. Client: King Mill Associates Ll | Permit type: Electrical permit | Permit status: Expired | Completion date: September 13, 2016 | Permit id: 721623 |