Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 379539 | |||||
Plumbing permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 719112 | |||||
Zoning admin review ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 659752 | |||||
New construction permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 670460 | |||||
Mechanical permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 713192 | |||||
Zoning admin review ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 649667 | |||||
Suppression permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 710297 | |||||
Permit for the erection of a three(3) story detached structure. ![]() Client: Alpha United Lp | Applicant: Stephen G. Pollock, Esquire | Permit type: Appeal | Permit status: Granted/prov | Completion date: May 11, 2012 | Permit id: 17075 | |||||
Zoning admin review ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 659752 | |||||
Electrical permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 718796 | |||||
New construction permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 670460 | |||||
Plumbing permit ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 719112 | |||||
Mechanical permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 713192 | |||||
Zoning use permit ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 379539 | |||||
Zoning admin review ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 649667 | |||||
Administrative permit ![]() Client: Alpha United Lp | Permit status: Completed | Permit id: 728776 | |||||
Suppression permit ![]() Client: Alpha United Lp | Permit status: Active | Permit id: 710297 | |||||
Permit for the erection of a three(3) story detached structure. ![]() Client: Alpha United Lp | Applicant: Stephen G. Pollock, Esquire | Permit type: Appeal | Permit status: Granted/prov | Completion date: May 11, 2012 | Permit id: 17075 | |||||
Administrative approval of previous permit 379539 granted under zba cal. No. 17075 issued on 10 10 13 to document addition of roof deck with pilot house, to increase building height, add egress wells, correct the depth and decrease the building depth as per approved plans. ![]() Client: Alpha United Lp | Permit type: Zoning admin review | Permit status: Completed | Completion date: January 14, 2016 | Permit id: 649667 | |||||
For the erection of an attached structure with a roof deck accessed by a pilot house, used as multi-family household living (three (3) dwelling units). Size and location as shown on plans application. ![]() Client: Alpha United Lp | Permit type: New construction permit | Permit status: Completed | Completion date: April 27, 2017 | Permit id: 670460 | |||||
Extend permit # 379539 pursuant to pa act 46 & 87. This extension to expire on july 1, 2016 unless extended by other portions of the philadelphia code ![]() Client: Alpha United Lp | Permit type: Zoning admin review | Permit status: Completed | Completion date: December 22, 2015 | Permit id: 659752 | |||||
SCORE 93 Interior plumbing construction for a new (3)story (3)family structure - note: exterior & 5" sewer 1" water connections to the city mains require separate permit(s) - vent terminals at the roof deck level must comply with section p-1103. 4. 1 of the philadelphia plumbing code 2004 - cpvc water supply piping is approved per section p-809. 2 of the philadelphia plumbing code 2004 - pex water supply piping is approved per the departments "code bulletin of information no. 0901 r3" - schedule pvc is approved for drain, waste & vent piping per sections p-902. 5, p-1005. 5 & p-1102. 3 of the philadelphia plumbing code 2004 ![]() ![]() Client: Alpha United Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 17, 2017 | Permit id: 700571 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a multi-family dwelling in accordance with nfpa 13 standards, and for the installation of a manual wet standpipe system in accordance with nfpa 14 standards. System is equipped with a backflow prevention assembly, and is serviced via a 2" fire service main line. ![]() ![]() Client: Alpha United Lp | Permit type: Suppression permit | Permit status: Completed | Completion date: April 17, 2017 | Permit id: 710297 | |||||
Installation of three (3) split systems (3 ton 60,0 btu in basement 1st floor; 2 ton 40,0 btu in second and third floor units) with associated ductwork, grilles, registers, diffusers and bathroom exhaust fans per plans for a three (3) family dwelling. All condensing units to be mounted at roof level. Separate permits required for all electrical and plumbing work. ![]() Client: Alpha United Lp | Permit type: Mechanical permit | Permit status: Completed | Completion date: March 27, 2017 | Permit id: 713192 | |||||
SCORE 100 Install 300amp service, wiring of a triplex- outlets, switches,9-120v smokes,6 cables and lights per 2008 nec (triplex)cc district install fire alarm system per nfpa 72 ![]() ![]() Client: Alpha United Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: March 27, 2017 | Permit id: 718796 | |||||
SCORE 93 Install new 5x4 curb trap, fai, 5" lateral and (3) 3 4" domestic water services-pa1#20162440604-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Client: Alpha United Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 26, 2016 | Permit id: 719112 |