Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: April 28, 2016 Client: Wong Brent N Man-Wong Stephanie | Permit status: Completed | Permit id: 688141 | |||||
Demolition permit Date: August 1, 2016 Client: Wong Brent N Man-Wong Stephanie | Permit status: Active | Permit id: 711439 | |||||
Demolition permit Date: August 1, 2016 Client: Wong Brent N Man-Wong Stephanie | Permit status: Completed | Permit id: 711439 | |||||
Plumbing permit Date: April 28, 2016 Client: Wong Brent N Man-Wong Stephanie | Permit status: Completed | Permit id: 688141 | |||||
Alteration permit Date: November 10, 2016 Client: Wong Brent N Man-Wong Stephanie | Permit status: Active | Permit id: 732453 | |||||
SCORE 100 For the installation of a new two (2) inch fire service line with backflow preventor for the installation of a fire suppression system per nfpa 13r and nfpa 13. Fire suppression plans shall be in accordance with approved building plans. Any deviations will require updated plans. Date: November 1, 2017 Contractor: B. M. Consulting Services Inc Client: Wong Brent N Man-Wong Stephanie | Permit type: Suppression permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 820568 | |||||
Level ii alterations (no change of occupancy classification) to include third floor rear addition to a building with an existing office on the first floor and three (3) dwelling units on the second through fourth floors as per approved plans. All residential portions to be sprinklered. No roof deck on this permit, separate permit required separate permits required for mep & fire suppression work Date: July 24, 2017 Client: Wong Brent N Man-Wong Stephanie | Permit type: Addition permit | Permit status: Active | Completion date: October 2, 2017 | Permit id: 789710 | |||||
SCORE 100 Alteration: interior plumbing of an existing 4-story structure with an existing commercial space (office) on the 1st floor and (3) dwelling units on the 2nd through 4th floors. The installation will comply with the philadelphia plumbing code, 2004. Fuel gas piping is not part of this permit and a mechanical permit is required. Date: April 3, 2017 Contractor: Daine Barrett Client: Wong Brent N Man-Wong Stephanie | Permit type: Plumbing permit | Permit status: Active | Completion date: October 27, 2017 | Permit id: 762247 | |||||
SCORE 99 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: February 3, 2017 Contractor: Tiet D Nguyen Client: Wong Brent N Man-Wong Stephanie | Permit type: Mechanical permit | Permit status: Active | Completion date: October 16, 2017 | Permit id: 756619 | |||||
SCORE 99 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: April 17, 2017 Contractor: Van Thanh Llc Client: Wong Brent N Man-Wong Stephanie | Permit type: Mechanical permit | Permit status: Expired | Completion date: May 9, 2017 | Permit id: 775569 | |||||
SCORE 100 Replace curb trap,fai and part of house drain-pa1#20170811787-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: March 23, 2017 Contractor: Hilsford Vidal Client: Wong Brent N Man-Wong Stephanie | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 19, 2017 | Permit id: 768892 | |||||
SCORE 99 Install new 4 amps service, rewire apartments and store per 2008 nec (mixed use) cc district install new fire alarm system per nfpa 72 Date: March 9, 2017 Contractor: Tiet D Nguyen Client: Wong Brent N Man-Wong Stephanie | Permit type: Electrical permit | Permit status: Expired | Completion date: March 9, 2017 | Permit id: 756618 | |||||
SCORE 99 Level ii alterations (no change of occupancy) for renovations to existing first floor office space and second through fourth floor three family dwelling as per approved plans. Existing building not required to be sprinklered. Separate permits required for mep work Date: November 10, 2016 Contractor: Van Thanh Llc Client: Wong Brent N Man-Wong Stephanie | Permit type: Alteration permit | Permit status: Active | Completion date: November 9, 2017 | Permit id: 732453 | |||||
SCORE 99 Ez interior demolition- for the interior demolition of non load-bearing partition walls and ceilings as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. (call inspector before starting work to get ok to start) Date: August 1, 2016 Contractor: Kien Phung Gen Contractor Inc Client: Wong Brent N Man-Wong Stephanie | Permit type: Demolition permit | Permit status: Completed | Completion date: October 21, 2016 | Permit id: 711439 | |||||
SCORE 100 Replace water service pa20161191760(mixed use)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: April 28, 2016 Contractor: Hilsford Vidal Client: Wong Brent N Man-Wong Stephanie | Permit type: Plumbing permit | Permit status: Completed | Completion date: June 17, 2016 | Permit id: 688141 |