| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 62 Electrical Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 11041-90000-234 | |||||
Site prep for sfd Permit type: Grading | Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 10030-10000-008 | |||||
SCORE 62 New, single family dwelling with attached garage. Permit type: Bldg-new | Permit status: Cofo issued | Current use: 1 or 2 family dwelling | Permit id: 10010-10000-001 | |||||
Electrical Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-10000-062 | |||||
SCORE 96 Fire sprinkler installation in new single family residence. Permit type: Fire sprinkler | Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13043-20000-004 | |||||
SCORE 62 Supplemental permit to 10010-10000-00167 to revise the work descriptio Permit type: Bldg-alter/repair | Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 10010-10003-001 | |||||
SCORE 59 Complete work started through permit #10010-10000-00167. Work is 90% c Permit type: Bldg-alter/repair | Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 15016-10000-004 | |||||
SCORE 93 Electrical Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-10000-062 | |||||
SCORE 59 Electrical Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-10000-092 | |||||
SCORE 59 Complete work started through permit #10010-10000-00167. Work is 90% c Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 15016-10000-004 | |||||
SCORE 93 Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-10000-062 | |||||
SCORE 59 Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13041-10000-092 | |||||
SCORE 96 Fire sprinkler installation in new single family residence. Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 13043-20000-004 | |||||
SCORE 62 Supplemental permit to 10010-10000-00167 to revise the work descriptio Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 10010-10003-001 |