Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Replace 3 antennas ? Add 3 antennas for a total of 6 antennas on an existing smoke stack, install 1 cabinet on existing rooftop platform, install cable along existing cable path. ![]() Client: Palace Laundry Inc Linens Of The Week | Applicant: Palace Laundry Inc Linens Of The We; Brad Fleegle | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: An1300014 | |||||
Install 1 one new microwave antenna on existing smokestack. Run new microwave cable from existing cabinet to antenna location. ![]() Client: Palace Laundry Inc | Applicant: Palace Laundry Inc. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: An1300214 | |||||
First extension to building permit an1300014 ti expire 05/28/14 ![]() Client: Palace Laundry Inc. | Applicant: Brad Fleegle | Permit type: Miscellaneous | Permit status: Completed | Permit id: An1400030 | |||||
The proposed work consist on drilling twenty-one soil borings direct push technology, for soil and groundwater sampling. No monitoring wells will be installed. The depth of the soil borings is twenty-five feet and the diameter three inches. Soil borings will be backfilled according to applicable dc regulation -2 lbs bentonite 1 gallon water, as per site plan, work plan report, dc well schematic form and dc well construction application, for linens of the week project. ![]() Client: Ron Bubes Linens Of The Week | Applicant: Ron Bubes Linens Of The Week; Rps, Inc. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300341 | |||||
We will perform a total of two soil boring on the proposed site. The borings will be advanced to a depth of feet. The borings will be located within the bounds of the private property. The borings will be drilled utilizing 4. 25-inch hollow stem, continuous flight augers and/or mud rotary drilling. The borings will be performed utilizing an atv-mounted drill rig and will generate an approximate 6-inch annulus. After geotechnical exploration is completed, the borings/auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds bentonite powder to one gallon water. Borehole/auger probe abandonment will be performed by tremie-grouting via a positive-displacement pump from the bottom of the borehole/auger probe. ![]() Client: Palace Laundry Inc Linens Of The Week | Applicant: Esc Mid-Atlantic Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400323 | |||||
SCORE 56 The proposed work consist on drilling twenty-one soil borings direct push technology, for soil and groundwater sampling. No monitoring wells will be installed. The depth of the soil borings is twenty-five feet and the diameter three inches. Soil borings will be backfilled according to applicable dc regulation -2 lbs bentonite 1 gallon water, as per site plan, work plan report, dc well schematic form and dc well construction application, for linens of the week project. ![]() ![]() Client: Ron Bubes Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300341 | |||||
SCORE 56 Replace 3 antennas ? Add 3 antennas for a total of 6 antennas on an existing smoke stack, install 1 cabinet on existing rooftop platform, install cable along existing cable path. ![]() ![]() Client: Palace Laundry Inc Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: An1300014 | |||||
SCORE 56 The proposed work consist on drilling twenty-one soil borings direct push technology, for soil and groundwater sampling. No monitoring wells will be installed. The depth of the soil borings is twenty-five feet and the diameter three inches. Soil borings will be backfilled according to applicable dc regulation -2 lbs bentonite 1 gallon water, as per site plan, work plan report, dc well schematic form and dc well construction application, for linens of the week project. ![]() ![]() Client: Ron Bubes Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300341 | |||||
SCORE 70 We will perform a total of 4 soil borings on the proposed site to a depth of 45 feet below existing grades. The borings will be located within the bounds of the private property. The borings will be drilled utilizing 4. 25 hollow stem, continuous flight augers and/or mud rotary drilling. The borings will be performed utilizing a truck-mounted drill rig and will generate an approximate 6 inch annulus. After geotechnical exploration is completed, the borings/auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds of bentonite powder to one gallon of water. Borehole/auger probe abandonment will be performed by tremie-grouting via a positive displacement pump from the bottom of the borehole/auger probe. ![]() ![]() Client: Palace Laundry Inc Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1600107 | |||||
SCORE 56 Install 1 one new microwave antenna on existing smokestack. Run new microwave cable from existing cabinet to antenna location. ![]() ![]() Client: Palace Laundry Inc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: An1300214 | |||||
SCORE 56 Replace 3 antennas ? Add 3 antennas for a total of 6 antennas on an existing smoke stack, install 1 cabinet on existing rooftop platform, install cable along existing cable path. ![]() Client: Palace Laundry Inc Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: An1300014 | |||||
SCORE 56 The proposed work consist on drilling twenty-one soil borings direct push technology, for soil and groundwater sampling. No monitoring wells will be installed. The depth of the soil borings is twenty-five feet and the diameter three inches. Soil borings will be backfilled according to applicable dc regulation -2 lbs bentonite 1 gallon water, as per site plan, work plan report, dc well schematic form and dc well construction application, for linens of the week project. ![]() ![]() Client: Ron Bubes Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300341 | |||||
SCORE 93 Demolition of existing 3 story building leaving front facade ![]() ![]() Client: Holladay Corporation Holladay Corporation | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1503437 | |||||
SCORE 93 143 unit, new construction, apartment building with one level of below grade parking. A portion of the facade along lamont street will be saved and reused. The below grade parking will be cast in place concrete, with the above grade apartment building will be wood framing with brick and fiver cement cladding ![]() ![]() Client: Palace Laundry Inc | Permit type: New building | Permit status: Permit issued | Permit id: B1506848 | |||||
SCORE 70 We will perform a total of 4 soil borings on the proposed site to a depth of 45 feet below existing grades. The borings will be located within the bounds of the private property. The borings will be drilled utilizing 4. 25 hollow stem, continuous flight augers and or mud rotary drilling. The borings will be performed utilizing a truck-mounted drill rig and will generate an approximate 6 inch annulus. After geotechnical exploration is completed, the borings auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds of bentonite powder to one gallon of water. Borehole auger probe abandonment will be performed by tremie-grouting via a positive displacement pump from the bottom of the borehole auger probe. ![]() ![]() Client: Palace Laundry Inc Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1600107 | |||||
SCORE 62 Removal of one approximately 1,0 gallon underground storage tank that was encountered during excavation activities as part of site redevelopment. The contents of the ust are unknown, however suspected to formerly be gasoline. Earth work and sediment erosion controls are associated with sheeting, shoring, and excavation permit sh1600019.(existing permits ut1700005 & ut1700008) ![]() Client: Palace Laundry Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1700010 | |||||
SCORE 56 Removal of two kerosene underground storage tanks that were encountered during excavation activities as part of site redevelopment. Tank ids and estimated volume: 4-2,0 gal. And 5-2,0 gal. Earth work and sediment erosion controls are associated with sheeting, shoring, and excavation permit sh1600019. ![]() Client: N A Arcadia Holladay, Llc C O The Holladay Corporation | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1700008 | |||||
SCORE 56 Removal of (3) three underground tanks- (1) one of approx. 3,000- gallon and two (2) approximately 1,000-gallon each- underground storage tank sthat was encountered during excavation activities as part of site redevelopment. The contents of the ust are unknown. Earth work and sediment erosion controls are associated with sheeting, shoring, and excavation permit sh1600019. ![]() Client: Palace Laundry Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1700005 | |||||
SCORE 93 Excavation sheeting and shoring ![]() ![]() Client: Holladay Corporation | Permit type: Sheeting and shoring | Permit status: Permit issued | Permit id: Sh1600019 | |||||
SCORE 62 Environmental due diligence. Installation of 14, 3-inch direct push geoprobe soil borings to depths of 25 feet below subgrade- subgrade is approximately 13 feet below grade. Seven of the borings will be completed as temporary piezometers using 1-inch diameter pvc pipe. Borings temporary piezometers will be open no longer than 24 hours and will be abandoned on the same day as drilling by tremi-grouting, using 2 pounds bentonite to 1-gallon water slurry, per doee regulations. Idw will be properly managed. ![]() Client: Palace Laundry Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700079 | |||||
SCORE 56 Comprehensive site assessment as part of dc lust 2017-004 and vcp case 2016-039. Installation of eight 3-inch direct push geoprobe soil borings to depths of 25 feet below subgrade- subgrade is approximately 13 feet below grade. All of the borings will be completed as a 1. 5 or 2-inch diameter monitoring well using schedule tri-lock pvc casing and 0. 020-inch slotted tri-lock screen. Idw will be characterized and properly managed. ![]() Client: N A Arcadia Holladay, Llc, C O The Holladay Corp. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700237 | |||||
SCORE 83 Tower crane for jobsite use ![]() ![]() Client: Barr Concrete Barr Concrete | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Tc1700008 | |||||
SCORE 96 Electrical ![]() ![]() Client: Chevy Chase House Associates Limited Partnership | Permit status: Permit issued | Permit id: E1705257 | |||||
SCORE 96 Plumbing and gas ![]() ![]() Client: Chevy Chase House Associates Limited Partnership | Permit status: Permit issued | Permit id: P1704585 | |||||
SCORE 93 First extension to building permit an1300014 ti expire 05/28/14 ![]() ![]() Client: Palace Laundry Inc. | Permit type: Miscellaneous | Permit status: Completed | Permit id: An1400030 | |||||
SCORE 60 We will perform a total of two soil boring on the proposed site. The borings will be advanced to a depth of feet. The borings will be located within the bounds of the private property. The borings will be drilled utilizing 4. 25-inch hollow stem, continuous flight augers and/or mud rotary drilling. The borings will be performed utilizing an atv-mounted drill rig and will generate an approximate 6-inch annulus. After geotechnical exploration is completed, the borings/auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds bentonite powder to one gallon water. Borehole/auger probe abandonment will be performed by tremie-grouting via a positive-displacement pump from the bottom of the borehole/auger probe. ![]() ![]() Client: Palace Laundry Inc Linens Of The Week | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400323 | |||||
SCORE 56 Environmental due diligence. Installation of 18 3-inch direct-push geoprobe soil borings to depths of 15 and feet below surface grade. 8 of the borings will be completed as temporary piezometers using 1-inch diameter pvc pipe. Borings/piezometers will be open no longer than 24 hours and will be abandoned on the same day as drilling by tremi-grouting, using 2-pounds bentonite to 1-gallon water slurry, per doee regulation. Idw will be properly managed. ![]() ![]() Client: Na Palace Laundry Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1600124 | |||||
SCORE 93 First extension to building permit b1503437 to expire 9/11/16. ![]() ![]() Client: Holladay Corporation Holladay Corporation | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1604794 | |||||
SCORE 56 Renewal of permit #b1604794 to expire 3/11/2017 ![]() Client: Holladay Corporation Holladay Corporation | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1611005 | |||||
SCORE 74 Type of elevator: one (1) traction steel core passenger (7 floor). ![]() Client: Arcadia Place L.L.C. | Permit type: Elevator - new | Permit status: Permit issued | Permit id: En1702912 | |||||
SCORE 79 Plumbing and gas ![]() ![]() Client: Palace Laundry Inc | Permit status: Permit issued | Permit id: P1707065 | |||||
Plumbing and gas ![]() Client: Holladay Corporation | Permit status: Permit issued | Permit id: P1707407 |