Alteration permit Client: Kochs Joseph Anthony | Permit status: Active | Permit id: 743091 | |||||
SCORE 100 Install a 400amp service complete with 8 meters and disconnects to serve 7 apts and 1 house panel. Rewire entire property per 2008 nec (multi family) install a fire alarm system per nfpa 72 Client: Kochs Joseph Anthony | Permit type: Electrical permit | Permit status: Active | Completion date: June 16, 2017 | Permit id: 783559 | |||||
Amend alterations permit no. 743091 to revise interior dwelling unit layouts, revise ratings for floor ceiling and wall assemblies and include a sprinkler system throughout the building as per approved plans. New certificate of occupancy to be issued to document sprinkler system installation. Client: Kochs Joseph Anthony | Permit type: Administrative permit | Permit status: Active | Completion date: November 29, 2017 | Permit id: 821136 | |||||
SCORE 100 Alteration: interior plumbing for the renovations to an existing 3-story structure with (7) dwelling units. The installation shall comply with the philadelphia plumbing code, 2004. Client: Kochs Joseph Anthony | Permit type: Plumbing permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 787983 | |||||
SCORE 100 Replace lateral pa20172631288 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Client: Kochs Joseph Anthony | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 29, 2017 | Permit id: 819175 | |||||
Level iii alterations (no change of occupancy) for renovations to existing seven (7) family dwelling as per approved plans. Existing building not required to be sprinklered. Separate permits required for mep work Client: Kochs Joseph Anthony | Permit type: Alteration permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 743091 | |||||
SCORE 100 Replace 5" curb trp, 4" fresh air inlet and house drain pa one call #2017-2340828 Client: Kochs Joseph Anthony | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 29, 2017 | Permit id: 811650 | |||||
SCORE 100 Installation of (2) hvac units (1st floor front and back). Installation of (2) mini split systems (3rd floor). Including all associated accessories. Self-contained units. No penetration of fire rated walls. Multi-family Client: Kochs Joseph Anthony | Permit type: Mechanical permit | Permit status: Active | Completion date: June 16, 2017 | Permit id: 785128 | |||||
SCORE 100 For the installation of a 2-inch fire service line for an automatic fire suppression sprinkler system with a backflow prevention assembly in accordance with nfpa 13r Client: Kochs Joseph Anthony | Permit type: Suppression permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 793866 | |||||
SCORE 100 Remove existing shingles and flat roof and reinstall new roof. (sfd) Client: Kochs Joseph Anthony | Permit type: Alteration permit | Permit status: Expired | Completion date: March 20, 2017 | Permit id: 761314 |