Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
New construction permit Date: November 28, 2014 Permit status: Active | Permit id: 564628 | |||||
Plumbing permit Date: November 25, 2015 Permit status: Completed | Permit id: 652832 | |||||
Electrical permit Date: December 16, 2015 Permit status: Expired | Permit id: 652229 | |||||
Mechanical permit Date: July 27, 2016 Permit status: Active | Permit id: 707016 | |||||
Administrative permit Date: September 26, 2014 Permit status: Completed | Permit id: 562837 | |||||
Zoning admin review Date: August 13, 2014 Permit status: Completed | Permit id: 546953 | |||||
Administrative permit Date: May 11, 2016 Permit status: Completed | Permit id: 691122 | |||||
Sign permit Date: August 4, 2016 Permit status: Active | Permit id: 709395 | |||||
Zoning/use permit Date: August 18, 2016 Permit status: Completed | Permit id: 689940 | |||||
Suppression permit Date: June 27, 2016 Permit status: Active | Permit id: 703192 | |||||
Zoning/use permit Date: September 18, 2013 Permit status: Completed | Permit id: 472906 | |||||
Electrical permit Date: April 29, 2016 Permit status: Completed | Permit id: 678806 | |||||
New construction permit Date: November 27, 2013 Permit status: Completed | Permit id: 501805 | |||||
Use permit Date: January 11, 2016 Permit status: Completed | Permit id: 661621 | |||||
Zoning/use permit Date: March 9, 2007 Permit status: Completed | Permit id: 52978 | |||||
Plumbing permit Date: March 1, 2016 Permit status: Completed | Permit id: 671042 | |||||
Administrative permit Date: June 9, 2015 Permit status: Completed | Permit id: 608447 | |||||
Alteration permit Date: April 15, 2016 Permit status: Completed | Permit id: 684692 | |||||
Mechanical permit Date: March 16, 2015 Permit status: Active | Permit id: 581304 | |||||
New construction permit Date: June 27, 2007 Permit status: Expired | Permit id: 84823 | |||||
Electrical permit Date: November 14, 2014 Permit status: Completed | Permit id: 574318 | |||||
Plumbing permit Date: June 13, 2008 Permit status: Expired | Permit id: 158355 | |||||
Suppression permit Date: July 15, 2015 Permit status: Active | Permit id: 607144 | |||||
Alteration permit Date: December 8, 2015 Permit status: Completed | Permit id: 653494 | |||||
Special exception/permit for the erection of a detached structure with decks throughout the structure and a roof deck on a portion of the 28th floor (with a swimming pool). For use as vacant commercial/retail space (use registration permit required prior to occupancy) on the 1st floor, business and professional offices on the 2nd floor, a total of two-hundred seventy-eight (278) dwelling units on the 3rd - 27th floors with accessory residential amenities on the 28th floor and an accessory parking garage on part of the 1st - 5th floors and 5th floor roof, with a total of two-hundred twenty-three (223) parking spaces, including one hundred eighty (180) standard spaces, thirty-six (36) compact spaces, seven (7) accessible spaces, and one hundred-eight (108) bicycle parking spaces located on an accessible route; 80% of the parking to be private and 20% available to the public. Two (2) loading spaces and enclosed trash storage located on the 1st floor. No signs on this application. Size and Date: June 18, 2013 Applicant: Ronald J. Patterson, Esq./ Carl S. Primavera, Esq. | Permit type: Appeal | Permit status: Granted | Completion date: September 27, 2013 | Permit id: 20722 | |||||
Permit for the twenty-five (25) story structure (maximum height 266 feet) including with enclosed mechanicals penthouse floors, for the creation of accessory private and public parking garages for a total of 286 spaces ( standard 173 spaces, 106 compact spaces ( 28 tendem and 5 philly car share) and 7h/c spaces , 1 bicycle spaces , creation of two(2) loading bays ( 2 for the retail spaces and one for the residentials) with accessory trash storage/enclosure, mechanicals and accessory storag from c1 -c5 floors, residential lobby, retail/commercial space, loading, trash room and mechanicals on first floor, retail commercial space on second floor( use registration permit required prior to occupancy) , fitness center, business center/conference center, accessory lounge, accessory outdoor pool and terrace, mechanicals and green roof on third floor, 293 dwelling units from 3rd thru 23 floors, mechanicals, elevator room penthouse and greenroof on 24th floor and mechanical penthouse on 25th flo Date: October 31, 2012 Applicant: Ronald Patterson, Esquire | Permit type: Appeal | Permit status: Granted | Permit id: 19210 | |||||
Permit for the erection of three (3) accessory, statically illuminated wall signs (signs 3b, 3c, and 5a on plans), and one (1) accessory, double-faced, statically illuminated projection directional sign (sign 4b on plans), sizes and locations as shown on plans/application. Signs 3b, 3c accessory to the building, sign 4b accessory to parking garage in tennant space #4, and sign 5a accessory to previously approved business & professional office on the second floor of a previously approved detached structure currently under construction. Date: May 31, 2016 Applicant: Ronald Patterson, Esq. | Permit type: Appeal | Permit status: Granted | Permit id: 27971 | |||||
New construction permit Date: November 28, 2014 Permit status: Completed | Permit id: 564628 | |||||
Electrical permit Date: February 16, 2016 Permit status: Completed | Permit id: 662917 | |||||
Administrative permit Date: October 11, 2016 Permit status: Completed | Permit id: 728320 | |||||
New construction permit Date: November 27, 2013 Permit status: Completed | Permit id: 501805 | |||||
Electrical permit Date: December 16, 2015 Permit status: Expired | Permit id: 652229 | |||||
New construction permit Date: June 27, 2007 Permit status: Expired | Permit id: 84823 | |||||
Zoning use permit Date: March 9, 2007 Permit status: Completed | Permit id: 52978 | |||||
Suppression permit Date: February 23, 2016 Permit status: Completed | Permit id: 671714 | |||||
Alteration permit Date: December 8, 2015 Permit status: Completed | Permit id: 653494 | |||||
Zoning use permit Date: August 8, 2016 Permit status: Completed | Permit id: 690856 | |||||
Plumbing permit Date: April 20, 2015 Permit status: Completed | Permit id: 599537 | |||||
Suppression permit Date: July 15, 2015 Permit status: Completed | Permit id: 607144 | |||||
Plumbing permit Date: June 13, 2008 Permit status: Expired | Permit id: 158355 | |||||
Sign permit Date: May 18, 2016 Permit status: Completed | Permit id: 684771 | |||||
Mechanical permit Date: February 8, 2016 Permit status: Completed | Permit id: 667799 | |||||
Administrative permit Date: June 9, 2015 Permit status: Completed | Permit id: 608447 | |||||
Zoning admin review Date: August 13, 2014 Permit status: Completed | Permit id: 546953 | |||||
Zoning use permit Date: September 18, 2013 Permit status: Completed | Permit id: 472906 | |||||
Administrative permit Date: December 19, 2014 Permit status: Completed | Permit id: 578435 | |||||
Mechanical permit Date: December 2, 2015 Permit status: Completed | Permit id: 651087 | |||||
Plumbing permit Date: July 15, 2016 Permit status: Completed | Permit id: 698752 | |||||
Suppression permit Date: January 5, 2017 Permit status: Active | Permit id: 748087 | |||||
Use permit Date: January 11, 2016 Permit status: Completed | Permit id: 661621 | |||||
Alteration permit Date: February 8, 2016 Permit status: Completed | Permit id: 658073 | |||||
Electrical permit Date: November 14, 2014 Permit status: Completed | Permit id: 574318 | |||||
Permit for the erection of three (3) accessory, statically illuminated wall signs (signs 3b, 3c, and 5a on plans), and one (1) accessory, double-faced, statically illuminated projection directional sign (sign 4b on plans), sizes and locations as shown on plans application. Signs 3b, 3c accessory to the building, sign 4b accessory to parking garage in tennant space #4, and sign 5a accessory to previously approved business & professional office on the second floor of a previously approved detached structure currently under construction. Date: May 31, 2016 Applicant: Ronald Patterson, Esq. | Permit type: Appeal | Permit status: Granted | Completion date: January 23, 2017 | Permit id: 27971 | |||||
Special exception permit for the erection of a detached structure with decks throughout the structure and a roof deck on a portion of the 28th floor (with a swimming pool). For use as vacant commercial retail space (use registration permit required prior to occupancy) on the 1st floor, business and professional offices on the 2nd floor, a total of two-hundred seventy-eight (278) dwelling units on the 3rd - 27th floors with accessory residential amenities on the 28th floor and an accessory parking garage on part of the 1st - 5th floors and 5th floor roof, with a total of two-hundred twenty-three (223) parking spaces, including one hundred eighty (180) standard spaces, thirty-six (36) compact spaces, seven (7) accessible spaces, and one hundred-eight (108) bicycle parking spaces located on an accessible route; 80% of the parking to be private and 20% available to the public. Two (2) loading spaces and enclosed trash storage located on the 1st floor. No signs on this application. Size and Date: June 18, 2013 Applicant: Ronald J. Patterson, Esq./ Carl S. Primavera, Esq. | Permit type: Appeal | Permit status: Granted | Completion date: September 27, 2013 | Permit id: 20722 | |||||
Permit for the twenty-five (25) story structure (maximum height 266 feet) including with enclosed mechanicals penthouse floors, for the creation of accessory private and public parking garages for a total of 286 spaces ( standard 173 spaces, 106 compact spaces ( 28 tendem and 5 philly car share) and 7h c spaces , 1 bicycle spaces , creation of two(2) loading bays ( 2 for the retail spaces and one for the residentials) with accessory trash storage enclosure, mechanicals and accessory storag from c1 -c5 floors, residential lobby, retail commercial space, loading, trash room and mechanicals on first floor, retail commercial space on second floor( use registration permit required prior to occupancy) , fitness center, business center conference center, accessory lounge, accessory outdoor pool and terrace, mechanicals and green roof on third floor, 293 dwelling units from 3rd thru 23 floors, mechanicals, elevator room penthouse and greenroof on 24th floor and mechanical penthouse on 25th flo Date: October 31, 2012 Applicant: Ronald Patterson, Esquire | Permit type: Appeal | Permit status: Granted | Permit id: 19210 | |||||
SCORE 100 To amend permit #564628 to revise partial floor plans, add residential laundry room, add security gate in egress stairway, correct the occupancy classifications and construction type and all other minor changes as per letter provided by the design professional. Certificate of occupancy to be issued to reflect new occupancies and construction type. Date: June 9, 2015 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: July 3, 2015 | Permit id: 608447 | |||||
SCORE 100 Installation of automatic sprinkler system in high rise building (commercial space, parking garage, dwelling units and amenity spaces) excluding the trash chute and noted parking garage areas. Work to include two (2)-eight inch (8") fire service lines, two (2)-1,0 gpm 213 psi fire pumps installed in accordance with nfpa 20, four (4) class i standpipes at exit enclosures (three (3) automatic wet, one (1) manual dry) with hose connections installed in accordance with nfpa 14, two (2) backflow prevention devices, two (2) fire department connections (market st. & 20th st.), pressure reducing valves through 18th floor, sprinklers and associated piping in accordance with nfpa 13. Separate permits required for all electrical and plumbing work. Date: July 15, 2015 Contractor: Oliver Sprinkler Co Inc Permit type: Suppression permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 607144 | |||||
SCORE 100 Amend foundation permit #501804 for assembly and disassembly of tower crane to assist in construction of 28 story high rise mixed use structure. Date: December 19, 2014 Contractor: Madison Construction Company Permit type: Administrative permit | Permit status: Completed | Completion date: December 17, 2015 | Permit id: 578435 | |||||
SCORE 100 Install new sanitary,domestic water,gas,roof drains,garage drains to 28 story,321 unit apartment building and parking garage-the installation will comply with the philadelphia plumbing code 2004 Date: March 16, 2015 Contractor: Voegele Mechanical Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: November 30, 2016 | Permit id: 578394 | |||||
SCORE 100 Install temporary power to peco pad mount transformer for construction trailers & site work. Service is 1600a with #2 15kv cable on primary & 6 sets of 500mcm on secondary. Date: November 14, 2014 Contractor: Anmar Electrical Contractor In Permit type: Electrical permit | Permit status: Completed | Completion date: May 8, 2015 | Permit id: 574318 | |||||
SCORE 100 For the erection of a twenty-eight (28) story high-rise, mixed-use structure. Building to include first floor retail use, second floor office space, and rental housing units above. Building also contains an indoor outdoor rooftop amenities space, wading pool, and attached five (5) story parking garage. Separate permits required for mechanical, electrical, plumbing, and fire suppression systems. Foundation previously approved under permit #501805 & amended under permit #562837. Date: November 28, 2014 Contractor: Hunter Roberts Construction Gr Permit type: New construction permit | Permit status: Completed | Completion date: November 14, 2016 | Permit id: 564628 | |||||
SCORE 100 Inst 12"storm & sani lateral & ct & 15"lateral & ct pa20150300271"self-certifications are no longer permitted" - "all excavations & plumbing trenches in excess of 5 in depth must have approved shoring in place at the time of inspection Date: April 20, 2015 Contractor: Harry Stuhl Iii Permit type: Plumbing permit | Permit status: Completed | Completion date: June 26, 2015 | Permit id: 599537 | |||||
SCORE 100 Provide temp electric,hv electric service,switchboards,transformers,panelboards,load centers,devices,light fixtures,power to hvac equip,8001mhz das system,area of rescue riser,fa,telecom equip and wiring per 2008 nec (mixed use) Date: February 20, 2015 Contractor: Anmar Electrical Contractor In Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2016 | Permit id: 582486 | |||||
SCORE 100 For the installation of a new hvac system and associated ductwork, piping, heat pumps and cooling tower. All work per approved plans. Separate permit required for electrical, plumbing, fire suppression. Date: March 16, 2015 Contractor: Voegele Mechanical Inc Permit type: Mechanical permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 581304 | |||||
SCORE 100 Interior fit out of cvs: connect to existing 400amp service, install 1-125amp panels & 2-225 amp panel, 175 light fixtires, 105 recepts, 9 switches, connnections of 2 walk in coolers, 1 bailer connect 2 duct heaters & 1 lift as per 2008 nec (cc district) Date: March 14, 2016 Contractor: Goldsmith Associates Inc Permit type: Electrical permit | Permit status: Completed | Completion date: August 23, 2016 | Permit id: 668664 | |||||
For the installation of a new hvac system in tenant space #1. Structural alteration s to accomindate mechanical equiptment as approved in a p no 658073. Date: February 8, 2016 Permit type: Mechanical permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 667799 | |||||
For the erection of four (4) accessory, statically illuminated wall signs (1a, 1b, 2a, 4a on plans), one (1) accessory, statically illuminated building id sign (3a on plans), and two (2) accessory, statically illuminated, double-faced projection signs (1e, 2b on plans), sizes and locations as shown on plans. Sign 4a accessory to previously approved parking garage in tenant space #4, signs 1a, 1b, 1c, 1e all accessory to previously approved use of retail sale of sundries, pharmaceuticals, convenience sales; food beverages and groceries and consumer goods in tenant space #1, sign 3a accessory to the building, and signs 2a, 2b accessory to previously approved sit-down restaurant in tenant space #2. Date: March 4, 2016 Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 4, 2016 | Permit id: 665839 | |||||
SCORE 95 Furnish & install: speakers strobes, pull station, duct detectors, test switch & control modules as per nfpa72 Date: February 16, 2016 Contractor: Hatzel And Buehler Inc Permit type: Electrical permit | Permit status: Completed | Completion date: July 1, 2016 | Permit id: 662917 | |||||
For a retail sale of sundries, pharmaceuticals, convenience sales ; food beverages and groceries and consumer goods at space # 1 in the same building sit-down restaurant at space # 2 at first floor in an existing structure in the same building with all other uses as previously approved. No sign on this application. Date: January 11, 2016 Permit type: Use permit | Permit status: Completed | Completion date: January 11, 2016 | Permit id: 661621 | |||||
SCORE 95 Furnish and install lighting, power, tele data, duplex recpts,quad recepts, furniture feeds, occ sensors and all branch wiring per 2008 nec (office space)cc district Date: January 15, 2016 Contractor: Hatzel And Buehler Inc Permit type: Electrical permit | Permit status: Completed | Completion date: July 1, 2016 | Permit id: 657365 | |||||
To amend permit #564628 to provide blazeshield sprayed fire protection membrane to provide additional fire-resistance ratings as required and described in addendum dated 11 23 15. Date: January 7, 2016 Permit type: Administrative permit | Permit status: Completed | Completion date: April 11, 2016 | Permit id: 655476 | |||||
SCORE 100 New installation of hvac system and mechanicals, heat pumps, grilles, registers and diffusers, fans, ductwork in 2nd floor office floor portion of high rise as per plans and specifications Date: December 2, 2015 Contractor: Elliott Lewis Corporation Permit type: Mechanical permit | Permit status: Completed | Completion date: July 2, 2016 | Permit id: 651087 | |||||
Interior alterations to fit out tenant space #1 (previously vacant). Tenant fit out to include: new partitions, finishes, furnishings, layout of retail space, and structural supports for mechanical equipment. Building fully sprinklered. Additional permits req: electrical, plumbing, hvac, sprinklers, signs, approval of special inspector(s). No work requiring special inspections can be completed until an amended permit is issued to document the special inspector(s). Date: February 8, 2016 Permit type: Alteration permit | Permit status: Completed | Completion date: August 22, 2016 | Permit id: 658073 | |||||
SCORE 100 2nd floor - independence blue cross walk-in services plumbing alterations per the approved plans and the philadelphia plumbing code 2004 Date: November 25, 2015 Contractor: Elliott Lewis Corporation Permit type: Plumbing permit | Permit status: Completed | Completion date: July 6, 2016 | Permit id: 652832 | |||||
SCORE 93 Electrical: 28 cardreader systems with low voltage elctrical locks on 1,2,3,4,5,28,29,and 30th floor, using plenum rated cable cmp ft6 with fire release (all low voltage 30v) as per 2008 nec (cc district) Date: December 16, 2015 Contractor: Kastle Philadelphia Joint Vent Permit type: Electrical permit | Permit status: Expired | Completion date: December 16, 2015 | Permit id: 652229 | |||||
SCORE 100 Interior alterations, fit out including partitions, acoustical and gwb cling, doors, frames, hardware, millwork, accessible upgrades, bathrooms, painting and carpeting, furnishings to 2nd floor area and ground level lobby structural framing, column work. Additional permits req: electrical, plumbing, hvac, sprinklers & signs., Date: December 8, 2015 Contractor: Riff Group Llc The Permit type: Alteration permit | Permit status: Completed | Completion date: July 2, 2016 | Permit id: 653494 | |||||
SCORE 100 Fixture installation Date: June 13, 2008 Contractor: Lormar Mechanical Services Permit type: Plumbing permit | Permit status: Expired | Completion date: June 26, 2008 | Permit id: 158355 | |||||
Permit to amend a p no 472906 (cal # 20722) to elimination of interior balconies (increasing the gfa far), increase in the number of dwelling units from two hundred seventy-eight (278) dwellings to three hundred twenty-one (321), decrease in the number of parking spaces from two hundred seventeen (217) to two hundred fifteen (215) by eliminating two (2) standard spaces on floor 1 (no change to accessible spaces or compact spaces), reconfiguration of roof plan mechanical structures, decrease in building height from 370. 2 ft to 341. 4 ft. No change to previously approved uses. Size and location as shown on application plans. Date: August 13, 2014 Permit type: Zoning admin review | Permit status: Completed | Completion date: May 5, 2017 | Permit id: 546953 | |||||
Erection of a 14 story structure, 1866" in height, with 257 apartments on flrs. 2 thru 14; retail on the ground flr.;with a total of 158 underground parking spaces (of which 129 are underground acc. Parking spaces, 29 are underground acc. Public parking spaces, 6 are hanicapped spaces and 37 are compact spaces), and 5 reservoir spaces provided. Gross floor area is 272,318 sq. Ft. (403,524 sq. Ft. Permitted). Date: March 9, 2007 Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 13, 2007 | Permit id: 52978 | |||||
For the erection of a foundation to serve a future high-rise, mixed-use building as shown in approved plans. See zoning permit# 472906 for size and location of construction. Date: November 27, 2013 Permit type: New construction permit | Permit status: Completed | Completion date: October 23, 2015 | Permit id: 501805 | |||||
New construction of a (29) story building having a mix of residential, commercial retail, office and public private parking garage. Date: September 18, 2013 Permit type: Zoning/use permit | Permit status: Completed | Completion date: September 18, 2013 | Permit id: 472906 | |||||
SCORE 94 Install 200amp service, branch circuit wiring, light fixtures, recepts, power wiring & final connection to hvac as per 2008 nec (cc district) Date: October 27, 2016 Contractor: Timothy Ferris Permit type: Electrical permit | Permit status: Completed | Completion date: November 3, 2016 | Permit id: 709771 | |||||
SCORE 100 Installation of one (1) statically illuminated flat wall sign and one (1) non-illuminated double sided projecting sign as per approved plans. Separate zoning and building permits required for any signs fronting courtyard. Separate permits required for any electrical work Date: August 4, 2016 Contractor: Custom Finishers Inc Permit type: Sign permit | Permit status: Completed | Completion date: October 19, 2016 | Permit id: 709395 | |||||
SCORE 86 Ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: August 4, 2016 Contractor: J And S Fire Protection Inc Permit type: Suppression permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 712443 | |||||
SCORE 89 Installation of new hvac system for take out restaurant in ground level space #2 as per approved plans. See a p 707016 for kitchen exhaust equipment Date: July 27, 2016 Contractor: Marconi And Son Gen Contractor Permit type: Mechanical permit | Permit status: Completed | Completion date: May 2, 2017 | Permit id: 707808 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 26-28 Date: July 15, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: July 27, 2016 | Permit id: 707665 | |||||
SCORE 89 Installation of three (3) ul 7 listed captive aire kitchen exhaust hoods within a take out restaurant in ground level space #2 as per approved plans. Work to include all associated ductwork and exhaust and make up air fans. See a p 707808 for plans Date: July 27, 2016 Contractor: Marconi And Son Gen Contractor Permit type: Mechanical permit | Permit status: Completed | Completion date: November 2, 2016 | Permit id: 707016 | |||||
SCORE 100 Relocate (22) existing sprinkler heads in order to accommodate tenant layouts as per nfpa no. 13 and all local codes. Date: June 27, 2016 Contractor: A And S Sprinkler Co Inc Permit type: Suppression permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 703192 | |||||
SCORE 82 Installation of two (2) statically illuminated flat wall signs (channel letters) and two (2) statically illuminated double faced projecting signs for retail space #1 as per approved plans. Separat permits required for any electrical work Date: June 28, 2016 Contractor: Martino Signs Inc Permit type: Sign permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 700627 | |||||
SCORE 100 Alteration: interior plumbing fit-out for space #2, a 1st floor restaurant. The installation will comply with the philadelphia plumbing code, 2004. Pvc pipe materials are not permitted, per code sections p-902. 5 & p-1102. 3. Fuel gas piping is not part of this permit and requires a mechanical permit. Date: July 15, 2016 Contractor: G M Mechanical Permit type: Plumbing permit | Permit status: Completed | Completion date: November 2, 2016 | Permit id: 698752 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 21-25 Date: June 7, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: June 14, 2016 | Permit id: 697963 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 16 through level 20 Date: May 11, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: May 13, 2016 | Permit id: 691122 | |||||
SCORE 100 Erect on flat wall, channel letter sign (at east elevation) as per plans. Date: August 18, 2016 Contractor: Custom Finishers Inc Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 18, 2016 | Permit id: 689940 | |||||
For the erection of three (3) accessory, statically illuminated wall signs (signs 3b, 3c, and 5a on plans), and one (1) accessory, double-faced, statically illuminated projection directional sign (sign 4b on plans), sizes and locations as shown on plans application. Signs 3b, 3c accessory to the building, sign 4b accessory to parking garage in tennant space #4, and sign 5a accessory to previously approved business & professional office on the second floor of a previously approved detached structure currently under construction. Date: August 8, 2016 Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 8, 2016 | Permit id: 690856 | |||||
Foundation Date: June 27, 2007 Permit type: New construction permit | Permit status: Expired | Completion date: February 19, 2009 | Permit id: 84823 | |||||
SCORE 95 Annual maintenance permit per 2008 nec (cc district) Date: April 28, 2017 Contractor: Hatzel And Buehler Inc Permit type: Electrical permit | Permit status: Expired | Completion date: April 28, 2017 | Permit id: 779095 | |||||
SCORE 100 Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: January 5, 2017 Contractor: Oliver Sprinkler Co Inc Permit type: Suppression permit | Permit status: Completed | Completion date: March 27, 2017 | Permit id: 748087 | |||||
SCORE 83 Tco Date: November 3, 2016 Contractor: Lott Restaurant Construction Permit type: Administrative permit | Permit status: Completed | Completion date: November 3, 2016 | Permit id: 734053 | |||||
SCORE 100 New 29 story apartment tower and parking garage all levels updated tco l1 to l29 Date: October 11, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: October 20, 2016 | Permit id: 728320 | |||||
SCORE 94 Extend existing fire alarm system to protect naf naf space,adding 3 horn strobes,2 duct detectors,2 duct detectors control modules per nfpa 72 (cc district) Date: October 21, 2016 Contractor: Timothy Ferris Permit type: Electrical permit | Permit status: Expired | Completion date: November 3, 2016 | Permit id: 727694 | |||||
SCORE 100 Install 7-ip cameras and 6-speakers as per 2008 nec(cc district) Date: September 29, 2016 Contractor: Shoreline Electric Inc Permit type: Electrical permit | Permit status: Completed | Completion date: March 14, 2017 | Permit id: 725701 | |||||
SCORE 100 For the erection of a sign (3c) above an existing marquee extending over the right of way. Size and location as shown on application plans. Separate permit required for electrical work. Date: September 21, 2016 Contractor: Nova Industries Llc Permit type: Sign permit | Permit status: Completed | Completion date: October 26, 2016 | Permit id: 716043 | |||||
SCORE 100 Install (illuminated) signage on east elevation, as per plans. Date: September 15, 2016 Contractor: Custom Finishers Inc Permit type: Sign permit | Permit status: Completed | Completion date: October 19, 2016 | Permit id: 716041 | |||||
SCORE 100 For the installation of one (1) statically-illuminated building identification sign on a high-rise structure. Separate permit required for electrical system. Date: May 18, 2016 Contractor: Nova Industries Llc Permit type: Sign permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 684771 | |||||
SCORE 100 Sidewalk shed shelter platform shelter platform permit- erection of a sidewalk shelter platform as per engineered plans. Streets department permit required for sidewalk closure prior to the start of work. Date: April 15, 2016 Contractor: Superior Scaffold Services Inc Permit type: Alteration permit | Permit status: Completed | Completion date: July 23, 2016 | Permit id: 684692 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 11 through level 15 Date: April 15, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: April 25, 2016 | Permit id: 684584 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 9 and level 10 Date: March 11, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: April 7, 2016 | Permit id: 675739 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 3 and level 4 Date: March 11, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: April 7, 2016 | Permit id: 675738 | |||||
SCORE 100 Install 68 plenum rated category 5e for voice data and point of sale location,all cabling will be supported by j hooks and home run back to the communications equipment cabinet in electrical room with a longest run of 250ft as per 2008 nec (cc district) Date: May 26, 2016 Contractor: Goldhorn Elect Construction Co Permit type: Electrical permit | Permit status: Expired | Completion date: May 26, 2016 | Permit id: 674726 | |||||
SCORE 100 Temporary certificate of occupancy for residential tower level 1, level 2, level 5-8 Date: March 1, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: March 18, 2016 | Permit id: 673175 | |||||
SCORE 100 Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: February 23, 2016 Contractor: Fields Fire Protection Permit type: Suppression permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 671714 | |||||
Interior exterior alterations to fit out tenant space #2 (previously vacant). Tenant fit out to include: new partitions, finishes, furnishings, layout of restaurant kitchen space, and structural supports for mechanical equipment, structural work modifications, concrete floor slab work. Building fully sprinklered. Additional permits req: electrical, plumbing, hvac & hood ansul, sprinklers, signs. No out door seating on this permit Date: July 11, 2016 Permit type: Alteration permit | Permit status: Completed | Completion date: March 28, 2017 | Permit id: 671362 | |||||
SCORE 100 To amend permit #501805 to include updated geotechnical report and changes to caisson dimensions as shown in approved plans. Date: September 26, 2014 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: January 26, 2015 | Permit id: 562837 | |||||
SCORE 93 Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: February 17, 2016 Contractor: Mk Fire Protection And Supply Permit type: Suppression permit | Permit status: Completed | Completion date: July 2, 2016 | Permit id: 670321 | |||||
SCORE 100 Temporary certificate of occupancy for parking garage. Date: March 11, 2016 Contractor: Hunter Roberts Construction Gr Permit type: Administrative permit | Permit status: Completed | Completion date: March 22, 2016 | Permit id: 675736 | |||||
SCORE 100 Installation of owner supplied fire alarm system. 13 smokes, 4 pull stations, 8 ceiling horn stobes, 3 wall horn strobes, 1 exterior horn strobes, 2 heat detectors 1 control panel 1 fsa as per nfpa 72 cc district Date: April 29, 2016 Contractor: Armour And Sons Electric Inc Permit type: Electrical permit | Permit status: Completed | Completion date: September 8, 2016 | Permit id: 678806 | |||||
SCORE 86 Interior plumbing alterations in space #1 for the retail sale of sundries, pharmaceuticals, food, beverages, groceries & consumer goods (cvs pharmacy) - water supply backflow isolation protection devices must comply with table 608. 1 for the degree of hazard - the installation will comply with the approved plans and the philadelphia plumbing code 2004 Date: March 1, 2016 Contractor: Rosati Mechanical Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: July 23, 2016 | Permit id: 671042 |