Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 1931 N 32nd St Philadelphia Pa 191211705 Repair elect violation label all elect panel circuit breakers, cover all open slots, install new 110v recpt for hwh, cover all open junction boxes as per nec 2008 (multi family) Date: February 11, 2014 Contractor: Whitely Samuel Client: Friends Development Compa | Permit type: Electrical permit | Permit status: Expired | Completion date: February 11, 2014 | Permit id: 519235 | |||||
SCORE 100 1933 N 32nd St Philadelphia Pa 191211705 Repair electrical violations label all electrical panels cover all open slots install new 110v receptacles for hot water heater and cover all open junction boxes per 2008nec (multi family) Date: February 7, 2014 Contractor: Whitely Samuel Client: Friends Development Compa | Permit type: Electrical permit | Permit status: Expired | Completion date: February 7, 2014 | Permit id: 518916 | |||||
SCORE 100 1911 N 54th St Philadelphia Pa 191313221 Install 200amp svc, panel ele circuit,8" ground rod and cold water ground,2 amp master socket,80amp line for 2nd fl as per 2008 nec(comm + apt) Date: November 9, 2012 Contractor: Whitely Samuel Client: P & C Dream Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: January 8, 2013 | Permit id: 437298 | |||||
SCORE 100 2119 N 2nd St Philadelphia Pa 191221603 Remove and replace wire receptacles,switches and light fixtures. Install gfi recept in bathroom. Install smoke detection in all bedrooms and hallways as per 2005 (east district) Date: September 30, 2014 Contractor: Whitely Samuel Client: Palmer Sara | Permit type: Electrical permit | Permit status: Expired | Completion date: September 30, 2014 | Permit id: 564901 | |||||
SCORE 100 125 N 63rd St Philadelphia Pa 191392202 Install 200amp svc,2 lighting circuit or 1st fl & garage. 4-20amp cir,1at & 3rd fl,165 amp circuit garage as per 2008 nec(sfd) Date: February 4, 2013 Contractor: Whitely Samuel Client: Johnson Charles E Johnson Paula L | Permit type: Electrical permit | Permit status: Completed | Completion date: May 21, 2015 | Permit id: 451787 | |||||
SCORE 100 6705 Lincoln Dr Philadelphia Pa 191193119 Rewire switches, receptacles and light fixtures, as per 2005 nec (north dist) Date: May 4, 2009 Contractor: Whitely Samuel Client: Mingo Bernard Mingo Sharon | Permit type: Electrical permit | Permit status: Expired | Completion date: May 4, 2009 | Permit id: 213832 | |||||
SCORE 100 1263 E Chelten Ave Philadelphia Pa 191381928 Install 120v line for exhaust fan in kitchen area as per 2008 nec (north district) Date: November 14, 2013 Contractor: Whitely Samuel Client: Awes Dave O | Permit type: Electrical permit | Permit status: Expired | Completion date: November 14, 2013 | Permit id: 505987 | |||||
SCORE 100 2034 Mercy St Philadelphia Pa 191452807 Install 30amp 100amp main electric panel,lights,recepts,switches and covers throughout the house as per 2008 nec (south district) Date: October 31, 2016 Contractor: Whitely Samuel Client: Barton Irene E Matthew B D F | Permit type: Electrical permit | Permit status: Expired | Completion date: March 2, 2017 | Permit id: 733184 | |||||
SCORE 100 5 S Pleasant Pl Philadelphia Pa 191191414 Install 2 amp service with 4 gang meter socker as per nec 2008 (north district) Date: January 21, 2014 Contractor: Whitely Samuel Client: Cionca Larry J | Permit type: Electrical permit | Permit status: Expired | Completion date: January 21, 2014 | Permit id: 516090 | |||||
SCORE 100 2641 Parma Rd Philadelphia Pa 191312708 Install 100amp service cable & ckt panel, recept in kitchen & 3-recepts in bedrooms as per nec 2008 (sfd) Date: August 12, 2014 Contractor: Whitely Samuel Client: Rubin Steven | Permit type: Electrical permit | Permit status: Expired | Completion date: March 3, 2015 | Permit id: 555173 | |||||
SCORE 100 3 Fanshawe St Philadelphia Pa 191114606 Install 200amp service install circuit panel. Remove and replace all switches,lights,fixtures and receptacles. Replace all knob and tubing wiring per 2008 nec (sfd) Date: December 18, 2014 Contractor: Whitely Samuel Client: Nissley Steven | Permit type: Electrical permit | Permit status: Completed | Completion date: April 10, 2015 | Permit id: 580526 | |||||
SCORE 100 4 E Mermaid Ln Philadelphia Pa 191183241 Lobby install (5) amp rec and office install (8) amp rec (multi family)north district Date: May 10, 2016 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Expired | Completion date: May 10, 2016 | Permit id: 681781 | |||||
SCORE 100 4 E Mermaid Ln Philadelphia Pa 191183241 Remove and replace electric panel, remove and replace switches, receptacles, light fixtures and gfi as per 2008 nec (north district) Date: March 28, 2016 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Expired | Completion date: March 28, 2016 | Permit id: 677439 | |||||
SCORE 100 457 Fairmount Ave Philadelphia Pa 191232822 Install 4- electric heater for violation #422839 as per nec 2008 (mixed use) Date: April 10, 2014 Contractor: Whitely Samuel Client: Hvcp Properties Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 529770 | |||||
SCORE 100 729 Dorset St Philadelphia Pa 191190000 Install 200amp svc, cir panel w a main,8" ground rod and cold water ground,2 amp master socket as per 2008 nec(sfd) Date: November 9, 2012 Contractor: Whitely Samuel Client: Williams Nanette | Permit type: Electrical permit | Permit status: Completed | Completion date: December 10, 2012 | Permit id: 437302 | |||||
SCORE 100 1332 Orthodox St Philadelphia Pa 191243623 Install 350amp service with 6 gang meter sockets,remove & replace switches,recepts,gfi and light fixtures,remove and replace all electric heaters and thermostats,fishing only as per 2008 nec (east district) remove & replace fa panel,smoke detectors and strobes horns,fishing only as per nfpa72 Date: April 15, 2016 Contractor: Whitely Samuel Client: Stroff Steven | Permit type: Electrical permit | Permit status: Expired | Completion date: April 15, 2016 | Permit id: 652719 | |||||
SCORE 100 52 Overbrook Ave Philadelphia Pa 191312409 Total rewire install new smoke detector,sws,receptacles fixtures. Instal new electric panel per 2008 nec (sfd) Date: October 10, 2014 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Expired | Completion date: November 10, 2014 | Permit id: 567358 | |||||
SCORE 100 4926 Chestnut St Philadelphia Pa 191393516 Bathroom first floor - install gfi recept, light fixture and switch as per 2008 nec (west district) Date: January 31, 2014 Contractor: Whitely Samuel Client: Rgo Austin | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2014 | Permit id: 517896 | |||||
SCORE 100 1945 N 32nd St Philadelphia Pa 191211705 Repair electrical violations label all electrical panels cover all open slots install new 110v receptacles for hot water heater and cover all open junction boxes per 2008nec (multi family) Date: February 7, 2014 Contractor: Whitely Samuel Client: Friends Development Compa | Permit type: Electrical permit | Permit status: Expired | Completion date: February 7, 2014 | Permit id: 518921 | |||||
SCORE 100 1949 N 32nd St Philadelphia Pa 191211705 Repair elect violation label all elect panel circuit breakers, cover all open slots, install new 110v recpt for hwh, cover all open junction boxes as per nec 2008 (multi family) Date: February 11, 2014 Contractor: Whitely Samuel Client: Friends Development Compa | Permit type: Electrical permit | Permit status: Expired | Completion date: February 11, 2014 | Permit id: 519231 | |||||
SCORE 100 1935 N 32nd St Philadelphia Pa 191211705 Repair electrical violations label all electrical panels cover all open slots install new 110v receptacles for hot water heater and cover all open junction boxes per 2008nec (multi family) Date: February 7, 2014 Contractor: Whitely Samuel Client: Friends Development Compa | Permit type: Electrical permit | Permit status: Expired | Completion date: February 7, 2014 | Permit id: 518920 | |||||
SCORE 100 Date: December 21, 2012 Contractor: Whitely Samuel Client: Federal Realty Mgmt Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: January 10, 2013 | Permit id: 443589 | |||||
SCORE 100 103955 Frankford Ave Philadelphia Pa 191254115 Install 200amp service for fire pumps as per nec 2008 (multi units apt bldg) this permit is for the temporary installation only. Seperate plans permit is required for the permanent installation. Date: November 25, 2013 Contractor: Whitely Samuel Client: Frankford Lotfts Lp | Permit type: Electrical permit | Permit status: Expired | Completion date: November 25, 2013 | Permit id: 498878 | |||||
SCORE 100 2052 Fairmount Ave Philadelphia Pa 191302602 Install 5 ceiling light fixtures of switches,install 3 gfcis receptacles,install 4 20amp duplex receptacles as per 2008 nec Date: February 3, 2011 Contractor: Whitely Samuel Client: Santosusso Lisa | Client Company: Lisa Santosusso | Permit type: Electrical permit | Permit status: Expired | Completion date: February 3, 2011 | Permit id: 323343 | |||||
SCORE 100 1361 S Melville St Philadelphia Pa 191433718 Install 100amp service, circuit panel, install 100amp cable and meter socket, remove and replace switch receptacles, smokes and fixtures as per 2008 nec (west district) Date: August 19, 2016 Contractor: Whitely Samuel Client: Holts Shawna | Permit type: Electrical permit | Permit status: Expired | Completion date: August 19, 2016 | Permit id: 716164 | |||||
SCORE 100 56 Ridge Ave Philadelphia Pa 191282730 Remove & replace 12 light fixtures, 3-switches & 1-emergency exit fixtures (comm) replace of the same kind no addl wiring as per nec 2008 north district Date: June 26, 2014 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Expired | Completion date: March 3, 2015 | Permit id: 545658 | |||||
SCORE 100 1332 Yerkes St Philadelphia Pa 191191549 200a service and complete rewire in accordance with 2008 nec(sfd)(north dist) Date: January 15, 2013 Contractor: Whitely Samuel Client: Cooley Andre Cooley Donna | Permit type: Electrical permit | Permit status: Completed | Completion date: September 30, 2013 | Permit id: 447982 | |||||
SCORE 100 1909 Wilder St Philadelphia Pa 191464640 Install 200amp service with circuit panel only with no wiring as per 2008 nec (south district) Date: May 18, 2017 Contractor: Whitely Samuel Client: Amelia Investors Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 18, 2017 | Permit id: 784937 | |||||
SCORE 100 2017 Walnut St Philadelphia Pa 191034403 Install 4 amp service and meter socket, install 2-2 amp panel circuits as per 2008 nec (cc district) Date: August 1, 2016 Contractor: Whitely Samuel Client: Nine Roots Lp | Permit type: Electrical permit | Permit status: Abandoned | Completion date: August 1, 2016 | Permit id: 685021 | |||||
SCORE 100 5611 Wynnefield Ave Philadelphia Pa 191311327 Install 200svc, 40circuit panel and 2 amp meter socket plus all grounding as per 2008 nec (west dist) Date: October 19, 2011 Contractor: Whitely Samuel Client: Jackson Edgar Jackson Daniel W | Permit type: Electrical permit | Permit status: Expired | Completion date: October 19, 2011 | Permit id: 369342 | |||||
SCORE 100 5741 Walton Ave Philadelphia Pa 191432427 Install 2 gfi, 2 regualr receptacles in kitchen install smoke detector in three bedroom and one in dinning room install 4 high hat lighting fixture kitchen per 2008 nec (sfd) Date: June 5, 2013 Contractor: Whitely Samuel Client: Thaxton Mary Elizabeth Thaxton Mary Elizabeth Tr | Permit type: Electrical permit | Permit status: Expired | Completion date: June 5, 2013 | Permit id: 475727 | |||||
SCORE 100 3208 W York St Philadelphia Pa 191323339 Ez permit standard alterations - for alterations to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Work to include repair floors on 1st floor. Repair roof. Contractor has no employees. No other work permitted on this permit. Call the district inspector at least 24 hours prior to the start of work. Date: July 20, 2017 Contractor: Whitely Samuel Client: Naldson Ernest A | Permit type: Alteration permit | Permit status: Active | Completion date: August 11, 2017 | Permit id: 800216 | |||||
SCORE 100 5338 Wingohocking Ter Philadelphia Pa 191445832 Install 200amp service, wire recpts, switches, gfi throughout as per nec 2008 (sfd) Date: October 3, 2013 Contractor: Whitely Samuel Client: Kochiashvili Giorgio | Permit type: Electrical permit | Permit status: Completed | Completion date: May 2, 2014 | Permit id: 498581 | |||||
SCORE 100 532 N Vogdes St Philadelphia Pa 191314905 Install new outside service line 100amp, new panel 100amp, gold water and 8ground rod as per 2005 nec (west district) Date: July 21, 2008 Contractor: Whitely Samuel Client: Randolph Leroy | Permit type: Electrical permit | Permit status: Expired | Completion date: July 21, 2008 | Permit id: 165684 | |||||
SCORE 100 118 W Sharpnack St Philadelphia Pa 191194033 Install 200amp service rewire 1st,2nd and 3rd from switch,receptacles,lights,fixtures and gfis per 2008 nec (sfd) Date: October 17, 2013 Contractor: Whitely Samuel Client: Nemer Daniel Nemer Rachel | Permit type: Electrical permit | Permit status: Completed | Completion date: August 23, 2016 | Permit id: 501039 | |||||
SCORE 100 435 Sentner St Philadelphia Pa 191201632 Install new circuit, 1 amp panel, remove and replace switches and receptacles as per 2008 nec (east district) Date: August 19, 2016 Contractor: Whitely Samuel Client: Livingston Quinzell L | Permit type: Electrical permit | Permit status: Completed | Completion date: September 28, 2016 | Permit id: 716163 | |||||
SCORE 100 4236 Powelton Ave Philadelphia Pa 191042104 Total rewire & install 100amp service, new switches, recepts, lite fixtures, gfis & smoke detectors as per nec 2008 (sfd) west district Date: June 26, 2014 Contractor: Whitely Samuel Client: Jmv Properties Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: April 4, 2017 | Permit id: 545659 | |||||
SCORE 100 261113 W York St Philadelphia Pa 191323510 Legalizing work done by others as per drawings. Repair wire and connections at front gate. Ground all service wires. Support sealtight at front gate. Close all open raceways. Close all open slots in electrical panel. Rewire service for apartments a & b. Install 4 amp 3-phase disconnect and ground as per 2008 nec. (north district) Date: May 18, 2016 Contractor: Whitely Samuel Client: Wells Fargo Bank National | Client Company: Donaldson Ernest A | Permit type: Electrical permit | Permit status: Completed | Completion date: March 13, 2017 | Permit id: 657713 | |||||
SCORE 100 7243 Saul St Philadelphia Pa 191491218 Installing 100amp service, circuit electrical panel and meter socket per 2008 nec (sfd) Date: November 29, 2013 Contractor: Whitely Samuel Client: Galant Shraga | Permit type: Electrical permit | Permit status: Completed | Completion date: May 22, 2014 | Permit id: 508723 | |||||
SCORE 100 53745 E Wyoming Ave Philadelphia Pa 191204509 Install pull stations, smoke & heat detectors as per nec 2008 & nfpa 72 (church) Date: October 3, 2013 Contractor: Whitely Samuel Client: Congregatn Beth Uziel | Permit type: Electrical permit | Permit status: Expired | Completion date: October 3, 2013 | Permit id: 487971 | |||||
SCORE 100 3466 Saint Vincent St Philadelphia Pa 191491626 Installing outside 20amp disconnect for chair lift per 2008 nec (sfd) Date: May 22, 2013 Contractor: Whitely Samuel Client: Fang Jie | Permit type: Electrical permit | Permit status: Expired | Completion date: May 22, 2013 | Permit id: 473076 | |||||
SCORE 100 8 South St Philadelphia Pa 191472025 Install two exit emergency light per 2008 nec (mixed use)south district Date: December 7, 2016 Contractor: Whitely Samuel Client: Johnson Sunyun Y | Permit type: Electrical permit | Permit status: Completed | Completion date: March 15, 2017 | Permit id: 741716 | |||||
SCORE 100 5311 Woodbine Ave Philadelphia Pa 191312429 Install 200amp service & total rewire (sfd) as per nec 2008 west district Date: February 6, 2015 Contractor: Whitely Samuel Client: Samuel Calvell O Samuel Lynette R | Permit type: Electrical permit | Permit status: Completed | Completion date: November 10, 2015 | Permit id: 589141 | |||||
SCORE 100 434 Winona St Philadelphia Pa 191440000 Install circuit and 100amp panel as per 2008 nec (north district) no additional wiring Date: July 29, 2016 Contractor: Whitely Samuel Client: Parrish Duwayne Parrish Dolly | Permit type: Electrical permit | Permit status: Completed | Completion date: October 26, 2016 | Permit id: 711191 | |||||
SCORE 100 11077 Waldemire Dr Philadelphia Pa 191544239 Install 1 amp service with circuit panel. Remove and replace receptacles, switches light fixtures and smoke detectors per 2008 nec (sfd)east district Date: March 15, 2016 Contractor: Whitely Samuel Client: Rosario Antonio Carbonetti Eugene | Permit type: Electrical permit | Permit status: Completed | Completion date: March 29, 2017 | Permit id: 676264 | |||||
SCORE 100 6653 Sprague St Philadelphia Pa 191193843 Relocate electric panel 100amp, install new service line from meter socket to panel 100amp as per 2005 (east district) Date: March 20, 2014 Contractor: Whitely Samuel Client: Flood Bethany Fawcett Melissa A | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 525459 | |||||
SCORE 100 3619 Spring Garden St Philadelphia Pa 191042351 Rewire 3rd floor bedroom, install new switches, recepts, light fixtures & smoke detector as per nec 2008 (triplex) west district Date: July 18, 2014 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Expired | Completion date: July 18, 2014 | Permit id: 550151 | |||||
SCORE 100 4455 N 6th St Philadelphia Pa 191402319 Install 200amp panel,receptacles,lights and switches and gfi per 2008 nec (church) Date: May 8, 2014 Contractor: Whitely Samuel Client: Sixth Street Management C | Permit type: Electrical permit | Permit status: Completed | Completion date: March 3, 2015 | Permit id: 535340 | |||||
SCORE 100 943298 E Roosevelt Blvd Philadelphia Pa 191154321 Remove and replace exit and emergency exit lights 2nd and 1st floor -3 combo emergency exit each floor 1st & 2nd floor exit lights as per 2008 nec (east district) Date: November 7, 2013 Contractor: Whitely Samuel Client: Merck Real Estate Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2015 | Permit id: 504777 | |||||
SCORE 100 2507 S Philip St Philadelphia Pa 191484722 Total rewire new receptacles,switches and light fixtures per 2008 nec (sfd) Date: May 29, 2014 Contractor: Whitely Samuel Client: Cunningham Samantha M Cunningham Owen L | Permit type: Electrical permit | Permit status: Expired | Completion date: May 29, 2014 | Permit id: 539480 | |||||
SCORE 100 Date: January 15, 2013 Contractor: Whitely Samuel Client: Murtaugh Laura | Permit type: Electrical permit | Permit status: Expired | Completion date: January 15, 2013 | Permit id: 447977 | |||||
SCORE 100 509 W Ruscomb St Philadelphia Pa 191203719 Install 100amp service,new switch receptacles and fixtures throughout house per 2008 nec (sfd) Date: May 1, 2014 Contractor: Whitely Samuel Client: Windburgh Residential Adv | Permit type: Electrical permit | Permit status: Completed | Completion date: November 9, 2015 | Permit id: 533851 | |||||
SCORE 100 5401 Wyndale Ave Philadelphia Pa 191311333 Total rewire, install new recept gfi, switches & smoke detector as per nec 2008 (sfd) west district Date: July 18, 2014 Contractor: Whitely Samuel Client: Lindsay Patrick G | Permit type: Electrical permit | Permit status: Completed | Completion date: April 27, 2016 | Permit id: 550162 | |||||
SCORE 100 6128 N Woodstock St Philadelphia Pa 191382439 Phase 1 removal and replace receptacles for tamper resist. Install four exit lights. Install exterior light timer. Install gfi receptacles in kitchen and utility room per 2008 nec (day care) Date: July 31, 2013 Contractor: Whitely Samuel Client: Young Tameka | Permit type: Electrical permit | Permit status: Expired | Completion date: July 31, 2013 | Permit id: 473080 | |||||
SCORE 100 6128 N Woodstock St Philadelphia Pa 191382439 Install two gfi receptacles in kitchen remove and replace old receptacles with tamper resist install four exit lights install exterior light fixtures per 2008 nec (daycare) Date: June 14, 2013 Contractor: Whitely Samuel Client: Young Tameka | Permit type: Electrical permit | Permit status: Expired | Completion date: June 14, 2013 | Permit id: 477455 | |||||
SCORE 100 15 S 19th St Philadelphia Pa 191464616 Remove & replace all wires, switches, recepts & light fixtures, install smoke detector throughout as per nec 2008 (sfd) Date: August 28, 2014 Contractor: Whitely Samuel Client: Porter Joyce I | Permit type: Electrical permit | Permit status: Expired | Completion date: March 25, 2015 | Permit id: 558516 | |||||
SCORE 100 13 N 18th St Philadelphia Pa 191215007 Installing rectacples switches,receptacles lights fixtures and replacing smoke detectors,strobes and pull stations per 2008 nec & nfpa 72 (multi family) same make and same model Date: May 16, 2014 Contractor: Whitely Samuel Client: Pullpal Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 537099 | |||||
SCORE 100 60 N 12th St Philadelphia Pa 191413204 Install 20amp outside disconnect for wheel chair lift circuit as per 2008 nec(sfd) Date: February 4, 2013 Contractor: Whitely Samuel Client: Rawls Geneva Tr Geneva Rawls Trust | Permit type: Electrical permit | Permit status: Expired | Completion date: February 4, 2013 | Permit id: 451785 | |||||
SCORE 100 503 S 41st St Philadelphia Pa 191044501 Apt 104&204 remove and replace wire,receptacles,switches,and gfi and apt103 remove and replace wires,receptacles and switches per 2008 nec (apt bldg) Date: January 8, 2015 Contractor: Whitely Samuel Client: Greenzang Properties Iii | Permit type: Electrical permit | Permit status: Completed | Completion date: August 9, 2017 | Permit id: 583319 | |||||
SCORE 100 1719 S 18th St Philadelphia Pa 191452149 200a service and complete rewire in accordance with 2008 nec(sfd)(south dist) Date: January 15, 2013 Contractor: Whitely Samuel Client: Tjokronolo Dunung G | Permit type: Electrical permit | Permit status: Completed | Completion date: September 30, 2013 | Permit id: 447978 | |||||
SCORE 100 7419 N 20th St Philadelphia Pa 191382201 Install 100amp service,smoke detectors 3 bedrooms,living room,basement,heat detectors in kitchen,new receptacles in kitchen and rear bedroom per 2008 nec (sfd) Date: May 1, 2014 Contractor: Whitely Samuel Client: Aniels Latonya | Permit type: Electrical permit | Permit status: Completed | Completion date: April 10, 2015 | Permit id: 533850 | |||||
SCORE 100 2001 S 11th St Philadelphia Pa 191482336 Install 200amp service,4 gang meter socket with 4 disconnect remove and replace switches,receptacles and light remove and replace each panel in apt with disconnect per 2008 nec (triplex) Date: December 16, 2013 Contractor: Whitely Samuel Client: Abf Holdings Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: December 16, 2013 | Permit id: 511414 | |||||
SCORE 100 12 N 52nd St Philadelphia Pa 191392643 Install 100amp service cable, circuit panel. Install receptacles in kitchen,2 rec main bedroom,1 receptacle middle bedroom per 2008 nec (sfd) Date: August 8, 2014 Contractor: Whitely Samuel Client: Pak Edward Jin | Permit type: Electrical permit | Permit status: Expired | Completion date: August 8, 2014 | Permit id: 554662 | |||||
SCORE 100 1233 W Hazzard St Philadelphia Pa 191331109 Install 2 amp service remove all nobe tube wire total rewire switches, receptacles and light fixtures. Install smoke detectors to accomodate as per nec 2008 north district Date: December 11, 2015 Contractor: Whitely Samuel Client: Stewart Edward | Permit type: Electrical permit | Permit status: Expired | Completion date: December 11, 2015 | Permit id: 657711 | |||||
SCORE 100 3621 Aramingo Ave Philadelphia Pa 191340000 Remove and replace 35 fixtures,3 receptacles and 3 switches per 2008 nec (restaurant) no additional wiring Date: July 18, 2017 Contractor: Whitely Samuel Client: Kdp Castor Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: August 9, 2017 | Permit id: 800732 | |||||
SCORE 100 59 E Pastorius St Philadelphia Pa 191442023 Install 200a service, 100a feeder to 2nd floor, proper grounding & rewire single family dwelling as per 2008 nec. Date: February 19, 2010 Contractor: Whitely Samuel Client: Kouyate Kyndalle | Permit type: Electrical permit | Permit status: Completed | Completion date: July 13, 2010 | Permit id: 263057 | |||||
SCORE 100 3601 Conshohocken Ave Philadelphia Pa 191315359 Remove and replace (9) circuit panels for units on an existing 100amp service as per 2008 nec (west district) no additional wiring Date: June 23, 2016 Contractor: Whitely Samuel Client: Gpx Ft Apartment Properti | Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2017 | Permit id: 700848 | |||||
SCORE 100 4931 Chancellor St Philadelphia Pa 191394223 Install 2 amp service remove & replace light fixtures. Receptacles, switch and ceiling from gfi receptacles. Install smoke detectors in accordances with nec per 2008 nec (sfd) Date: October 22, 2015 Contractor: Whitely Samuel Client: Chappelle Andre J Jones Monava | Permit type: Electrical permit | Permit status: Expired | Completion date: October 22, 2015 | Permit id: 647100 | |||||
SCORE 100 342 E Eleanor St Philadelphia Pa 191203910 Install 100amp ckt panel, remove & replace all switches, recepts, light fixtures, nob & tubing wires, install new smoke detectors & heat detector as per nec 2008 (sfd) east district Date: December 19, 2014 Contractor: Whitely Samuel Client: Blas Ruth Y Quispe | Permit type: Electrical permit | Permit status: Expired | Completion date: July 22, 2015 | Permit id: 580858 | |||||
SCORE 100 6802 Old York Rd Philadelphia Pa 191262842 Install new panel,new smoke detectors,new pull stations and new horn and strobes per nfpa 72 (mixed use)north district Date: January 29, 2016 Contractor: Whitely Samuel Client: James Howard James Karen | Permit type: Electrical permit | Permit status: Completed | Completion date: September 28, 2016 | Permit id: 659901 | |||||
SCORE 100 4605 Conshohocken Ave Philadelphia Pa 191311513 Install 1 amp service, line, meter socket & panel as per 2008 nec (west district) Date: March 29, 2010 Contractor: Whitely Samuel Client: Edmunds Stephani Hollis Dwayne | Permit type: Electrical permit | Permit status: Expired | Completion date: March 29, 2010 | Permit id: 269353 | |||||
SCORE 100 58 Elmwood Ave Philadelphia Pa 191436007 Installing 4 outside pole light and 120v electric for outside sign per 2008 nec (auto shop) Date: June 24, 2014 Contractor: Whitely Samuel Client: Annami Family Company | Permit type: Electrical permit | Permit status: Completed | Completion date: November 2, 2015 | Permit id: 545000 | |||||
SCORE 100 2041 Morris St Philadelphia Pa 191451424 Install 20amp outside disconnect for wheel chair lift as per 2008 nec(sfd) Date: February 4, 2013 Contractor: Whitely Samuel Client: Lamb Delores Lamb Valerie | Permit type: Electrical permit | Permit status: Expired | Completion date: February 4, 2013 | Permit id: 451786 | |||||
SCORE 100 919 Morris St Philadelphia Pa 191481111 Remove & replace all wiring, switches, recepts covers & gfi & fixtures, install smoke detector throughout, with addl wiring on this permit as per nec 2008 Date: September 11, 2014 Contractor: Whitely Samuel Client: Neilson Joseph T Iii | Permit type: Electrical permit | Permit status: Completed | Completion date: January 14, 2015 | Permit id: 561106 | |||||
SCORE 100 8834 Hargrave St Philadelphia Pa 191521511 11-high hats, 2-gfis, 3-switches & ceiling fan (sfd) as per nec 2008 Date: October 1, 2014 Contractor: Whitely Samuel Client: Allen Rudolph N Allen Coretha J | Permit type: Electrical permit | Permit status: Expired | Completion date: January 16, 2015 | Permit id: 565307 | |||||
SCORE 100 527 Franklin Mills Cir Philadelphia Pa 191543105 In kind with no additional wiring remove & 25-replace light fixtures & 10-switches & covers in kind with no additional wiring as per nec 2008 east district Date: April 20, 2017 Contractor: Whitely Samuel Client: Kfc U S Properties Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: July 12, 2017 | Permit id: 776979 | |||||
SCORE 100 3073 Chatham St Philadelphia Pa 191344306 Install 100amp service, install brach circuit wiring throughout as per nec 2008 (sfd) Date: March 7, 2014 Contractor: Whitely Samuel Client: Thompson Real Estate Asso | Permit type: Electrical permit | Permit status: Expired | Completion date: April 27, 2015 | Permit id: 523131 | |||||
SCORE 100 3851 Lancaster Ave Philadelphia Pa 191042356 Install two 15amp circuits for exhaust and supply fan as per nec 2008 (west district) Date: January 21, 2014 Contractor: Whitely Samuel Client: Haile Mulugetta Gebremicael Zerai | Permit type: Electrical permit | Permit status: Completed | Completion date: May 21, 2015 | Permit id: 516088 | |||||
SCORE 100 5314 Kingsessing Ave Philadelphia Pa 191434915 Install 20amp outside disconnect for wheel chair lift as per 2008 nec(sfd) Date: February 4, 2013 Contractor: Whitely Samuel Client: Jackson Eugene Reaves Elizabeth L | Permit type: Electrical permit | Permit status: Expired | Completion date: February 4, 2013 | Permit id: 451783 | |||||
SCORE 100 Date: May 20, 2014 Contractor: Whitely Samuel Client: Parker Bernard | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 537883 | |||||
SCORE 100 1313 Lafayette Pl Philadelphia Pa 191224120 Inspection on existing services, last time service has been on was in 2004, as per 2005 nec (east dist) Date: May 20, 2008 Contractor: Whitely Samuel Client: Mitchell Adrienne Clark Clark Mark Leroy | Permit type: Electrical permit | Permit status: Completed | Completion date: June 14, 2008 | Permit id: 153281 | |||||
SCORE 100 3401 W Girard Ave Philadelphia Pa 191040000 Install 29-high hat light fixtures,repair recepts on 1st and 2nd fl.,install gfi recepts in kitchen and bathroom,install light fixtures in bathroom and install 220v 30amp electric circuit for hwh as per 2008 nec (west district) Date: February 10, 2017 Contractor: Whitely Samuel Client: City Of Phila West Park Mann Music | Permit type: Electrical permit | Permit status: Expired | Completion date: February 10, 2017 | Permit id: 758417 | |||||
SCORE 100 58 Haverford Ave Philadelphia Pa 191314819 Install 2 amp service, 7- amp circuits, 5-15amp circuits as per nec 2008 (mixed use) Date: February 21, 2013 Contractor: Whitely Samuel Client: Mbj Property Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: August 15, 2015 | Permit id: 454698 | |||||
SCORE 100 Date: March 27, 2014 Contractor: Whitely Samuel Client: Coleman Kristen Marie | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 527086 | |||||
SCORE 100 430129 Chestnut St Philadelphia Pa 191043015 Install lights and receptacles per 2008 nec (retail space) Date: October 3, 2013 Contractor: Whitely Samuel Client: Pagano Theo Racciatti Robt | Permit type: Electrical permit | Permit status: Completed | Completion date: October 4, 2013 | Permit id: 468353 | |||||
SCORE 100 65 Lansdowne Ave Philadelphia Pa 191513704 Install new thermostat & repair wires in ceiling living room as per nec 2008 (2fd) Date: March 18, 2014 Contractor: Whitely Samuel Client: Jadeja Majur | Permit type: Electrical permit | Permit status: Expired | Completion date: March 18, 2014 | Permit id: 524810 | |||||
SCORE 100 2837 W Harold St Philadelphia Pa 191323119 Remove and replace all knob and tub wire. Install new switches,receptacles,covers light fixtures and smokes per 2008 nec (sfd)north district Date: December 22, 2015 Contractor: Whitely Samuel Client: Planners And Associates | Permit type: Electrical permit | Permit status: Expired | Completion date: December 22, 2015 | Permit id: 659904 | |||||
SCORE 100 2211 Dickinson St Philadelphia Pa 191464204 Install 200amp service with circuit panel only with no wiring as per 2008 nec (south district) Date: May 18, 2017 Contractor: Whitely Samuel Client: City View Rentals Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 18, 2017 | Permit id: 784953 | |||||
SCORE 100 611418 Lancaster Ave Philadelphia Pa 191513229 In kind with no additional wiring remove & 25-replace light fixtures & 10-switches & covers in kind with no additional wiring as per nec 2008 west district Date: April 20, 2017 Contractor: Whitely Samuel Client: Kfc Us Properties Inc | Permit type: Electrical permit | Permit status: Completed | Completion date: May 9, 2017 | Permit id: 776982 | |||||
SCORE 100 2226 Martha St Philadelphia Pa 191252026 Install 2 amp service with circuit panel and cable, 4 - 20amp rec gfi in kitchen, 3-15amp ark cb in bedrooms, 5-15 amp ark c b through out single family dwelling as per nec 2008 (east district) Date: February 5, 2014 Contractor: Whitely Samuel Client: Jewell Nicole | Permit type: Electrical permit | Permit status: Completed | Completion date: May 5, 2015 | Permit id: 516089 | |||||
SCORE 100 2008 Church Ln Philadelphia Pa 191382427 Installing 20amp outside disconnect for chair lift per 2008 nec (sfd) Date: May 22, 2013 Contractor: Whitely Samuel Client: Wilson Clara D I T F Wilson Michael | Permit type: Electrical permit | Permit status: Expired | Completion date: May 22, 2013 | Permit id: 473073 | |||||
SCORE 100 Date: May 1, 2014 Contractor: Whitely Samuel Client: Rocco J Lodise Edna V | Permit type: Electrical permit | Permit status: Completed | Completion date: April 22, 2015 | Permit id: 529769 | |||||
SCORE 100 3851 Lancaster Ave Philadelphia Pa 191042356 Replace gfi recpts, 1st & 2nd fl under sink, replace ceiling lgt in back room, outside entrance light fixture, sw, rewire outside sign light & light fixtures as per nec 2008 (bar) Date: October 3, 2013 Contractor: Whitely Samuel Client: Haile Mulugetta Gebremicael Zerai | Permit type: Electrical permit | Permit status: Expired | Completion date: October 3, 2013 | Permit id: 498580 | |||||
SCORE 100 3851 Lancaster Ave Philadelphia Pa 191042356 Install 200amp service, meter socket service line and circuit electric panel & grounding "only" as per 2008 nec(west dist) mixed use Date: April 26, 2012 Contractor: Whitely Samuel Client: Haile Mulugetta Gebremicael Zerai | Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2012 | Permit id: 401585 | |||||
SCORE 100 141012 Mckean St Philadelphia Pa 191450000 2nd and 3rd fl. With 4-apts.,remove and replace bedroom, living room, bathroom hallway, switches receptacles, ceiling light and ceiling fan. Kitchen remove and replace gfi receptacles, bathroom remove and replace gfci and light fixtures or wall,installing 4-100amp circuit panels,no main on meter outside as per 2008 nec (south district). No main fire alarm. Remove and replace pull station strobe horning and smoke detectors. Date: June 29, 2016 Contractor: Whitely Samuel Client: Sailor Partners Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: September 12, 2016 | Permit id: 681778 | |||||
SCORE 100 51 Parkside Ave Philadelphia Pa 191314715 Install 2 amp service, meter socket and panel as per 2008 nec (west dist) Date: June 28, 2010 Contractor: Whitely Samuel Client: Reid Joseph L Carmella H W | Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2015 | Permit id: 287985 | |||||
SCORE 100 10 E Durham St Philadelphia Pa 191502919 Install 1 amp service cable, install gfi in kitchen, install light in basement, all as per 2008 nec (north dist) Date: June 10, 2011 Contractor: Whitely Samuel Client: Watson Shirley L | Permit type: Electrical permit | Permit status: Expired | Completion date: June 10, 2011 | Permit id: 346459 | |||||
SCORE 100 879 Marcella St Philadelphia Pa 191241732 Install exhaust fan in basement bathroom as per 2008 nec (east dist) sfd Date: April 26, 2012 Contractor: Whitely Samuel Client: Solomon Tanya L | Permit type: Electrical permit | Permit status: Expired | Completion date: April 26, 2012 | Permit id: 401581 | |||||
SCORE 100 6221 Morton St Philadelphia Pa 191441612 Install new wires, recepts, switches, fixtures & smoke detector as per nec 2008 (sfd) Date: June 13, 2014 Contractor: Whitely Samuel Client: Rving Nefertiti K | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2014 | Permit id: 542942 | |||||
SCORE 100 4606 Horrocks St Philadelphia Pa 191243117 Remove and replace wire receptacles,switches and light fixtures. Install gfi recept in bathroom. Install smoke detection in all bedrooms and hallways as per 2005 (east district) Date: September 30, 2014 Contractor: Whitely Samuel Client: Montes Derrick Lopez Luis | Permit type: Electrical permit | Permit status: Expired | Completion date: September 30, 2014 | Permit id: 564900 | |||||
SCORE 100 2406 E Gordon St Philadelphia Pa 191252908 Install 100amp service & total rewire (sfd) as per nec 2008 east district Date: February 6, 2015 Contractor: Whitely Samuel Client: Brown Ellen | Permit type: Electrical permit | Permit status: Completed | Completion date: July 17, 2017 | Permit id: 589139 | |||||
SCORE 100 122 N Paxon St Philadelphia Pa 191392705 Install 2 amp service and rewire throughout as per 2008 nec. (west district) Date: March 23, 2015 Contractor: Whitely Samuel Client: Moyer Stephen A Moyer Laurie A | Permit type: Electrical permit | Permit status: Completed | Completion date: November 2, 2015 | Permit id: 597690 | |||||
SCORE 100 1932 Annin St Philadelphia Pa 191462908 Install 100amp service cable outside front per 2008 nec (sfd) Date: June 23, 2014 Contractor: Whitely Samuel Client: Arby Michael | Permit type: Electrical permit | Permit status: Expired | Completion date: June 23, 2014 | Permit id: 544708 | |||||
SCORE 100 2126 N 57th St Philadelphia Pa 191313033 Install 100amp service, new cable , 30-circuits panel & meter sockets as per nec 2008 (sfd) west district Date: July 18, 2014 Contractor: Whitely Samuel Client: Jerome Jackson Bessie | Permit type: Electrical permit | Permit status: Expired | Completion date: July 18, 2014 | Permit id: 550159 | |||||
SCORE 100 1729 Belfield Ave Philadelphia Pa 191411506 Install 200amp service cable, circuit electrical panel with 200amp main with no additional wiring as per 2008 nec (north district) Date: October 31, 2016 Contractor: Whitely Samuel Client: Locante Angelique J | Permit type: Electrical permit | Permit status: Completed | Completion date: March 21, 2017 | Permit id: 733194 | |||||
SCORE 100 1024 Belmont Ave Philadelphia Pa 191041212 Install 200amp service, circuit panel and cable, install 6 smoke detectors throughout a single family dwelling as per nec 2008 (west district) Date: January 21, 2014 Contractor: Whitely Samuel Client: Stinson Robert | Permit type: Electrical permit | Permit status: Completed | Completion date: May 28, 2015 | Permit id: 516087 | |||||
SCORE 100 510125 N Camac St Philadelphia Pa 191412803 Rewire one 2 bedroom apartment - 3- amp and 6-15 amp circuits, install a new amp circuit breaker panel with existing feeder cable as per 2008 nec (north district) Date: December 13, 2013 Contractor: Whitely Samuel Client: Camac Gardens Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: December 13, 2013 | Permit id: 511136 | |||||
SCORE 100 2 N Avondale St Philadelphia Pa 191391010 Install 200amp service, 30-circuit panel rewire 1st & 2nd floor, recpt & switch light fixtures as per nec 2008 (sfd) Date: August 8, 2013 Contractor: Whitely Samuel Client: Rummond Tamara | Permit type: Electrical permit | Permit status: Completed | Completion date: August 7, 2017 | Permit id: 487973 | |||||
SCORE 100 144 W Allens Ln Philadelphia Pa 191194102 Replace kitchen light fixtures and switches receptacles. Install new gfi receptacles in apt b17 per 2008 nec (apt bldg) Date: November 24, 2014 Contractor: Whitely Samuel Permit type: Electrical permit | Permit status: Completed | Completion date: April 22, 2015 | Permit id: 575968 | |||||
SCORE 100 29 Belgrade St Philadelphia Pa 191344953 Remove all knob & tube wiring, install new receptacles & light fixtures (sfd) as per nec 2008 east district Date: February 6, 2015 Contractor: Whitely Samuel Client: Szewc Diane | Permit type: Electrical permit | Permit status: Completed | Completion date: April 10, 2015 | Permit id: 589142 | |||||
SCORE 100 1024 Belmont Ave Philadelphia Pa 191041212 Install new wire recpts, switches, gfi throughout as per nec 2008 (sfd) Date: October 3, 2013 Contractor: Whitely Samuel Client: Stinson Robert | Permit type: Electrical permit | Permit status: Completed | Completion date: May 1, 2014 | Permit id: 498575 | |||||
SCORE 100 33 Brandywine St Philadelphia Pa 191042515 Install 200amp service cable,2 gang meter sockets. Install 7 new fixtures and smoke detectors per 2008 nec (sfd) Date: October 10, 2014 Contractor: Whitely Samuel Client: Lawson Matthew Lawson Megan | Client Company: Andrew Marson | Permit type: Electrical permit | Permit status: Completed | Completion date: January 26, 2015 | Permit id: 567362 | |||||
SCORE 100 1729 Belfield Ave Philadelphia Pa 191411506 Install 1 amp service cable & panel circuit, remove & replace switches, receptacle & gfi as per 2008 nec (north district) Date: September 27, 2016 Contractor: Whitely Samuel Client: Locante Angelique J | Permit type: Electrical permit | Permit status: Abandoned | Completion date: November 17, 2016 | Permit id: 725065 | |||||
SCORE 100 3858 Aspen St Philadelphia Pa 191041638 For interior alterations and renovation to create a two (2) family dwelling in an existing structure as per plans, no change in building foot-print permitted with this permit Date: December 5, 2017 Contractor: Whitely Samuel Client: Teklegiorgis Efrem Ghide Habtemariam | Permit type: Alteration permit | Permit status: Active | Completion date: December 14, 2017 | Permit id: 762956 | |||||
SCORE 100 2531 S 70th St Philadelphia Pa 191422100 Relocate fire alarm pull station and strobe light per nfpa 72. Devices will be relocate 2 feet form original area install two emergency light and exit signs per 2008 nec (house of worship) Date: December 8, 2017 Contractor: Whitely Samuel Client: The Trustee Of The Presbytery Of Phila | Permit type: Electrical permit | Permit status: Active | Completion date: December 8, 2017 | Permit id: 836975 |