Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 77 742744 Columbus Av Mission Hill Ma 02120 Providing temporary power service for the construction of the proposed northeastern university - columbus avenue student apartments a 3 0 + - square foot building housing 8 student dorms. Temporary power will be provided by a 2 000a 277 480v piece of switchgear that is fed from an eversource supplied 2 500kva 13. 8kv 277 480v padmount transformer. The switchgear will inturn feed a 500kva transformer that will stepdown the voltage to 120 208v. The temporary service will be utilized during construction to power the tower crane man material hoists welders heaters lighting etc. Client: Northeastern University | Permit type: Temporary service | Permit status: Open | Current use: Vacld | Permit id: Ets715320 | Parcel: 0901401000 | |||||
SCORE 77 99111 Seaport Bl Boston Ma 02210 The physical address of the project is actually 121 seaport blvd. The electrical work to be completed is comprised of the complete power lighting fire alarm and security for the proposed core and shell building. Improvements include 2 - 4000a permanent bldg services; a 1200a fire pump service; 2 - 4000a bus risers; a 300kva generator; 4 - 400a ats switches; as well as various power distribution equipment and the aforementioned systems servicing the entire building. Client: Ms Boston Seaport Llc | Permit type: Electrical | Permit status: Open | Current use: Vacld | Permit id: E693142 | Parcel: 0602640030 | |||||
SCORE 77 99111 Seaport Bl Boston Ma 02210 Actual address where work is to be done is at 121 seaport boulevard. Installation of a 480-v 3-phase 2000-amp temporary power system that will provide power for the construction of 121 seaport blvd. The power system will include a 400a 480v service connection every six floors power boxes every 3 floors and adequate lighting and power for all floors as per osha requirements. Client: Ms Boston Seaport Llc | Permit type: Temporary service | Permit status: Expired | Current use: Vacld | Permit id: Ets576607 | Parcel: 0602640030 | |||||
SCORE 77 99111 Seaport Bl Boston Ma 02210 Actual address where work is to be done is 121 seaport boulevard. Provide a complete analog addressable fire detection voice evacuation alarm and control network. System will be constructed in compliance with the submitted drawings and all applicable code requirements. Client: Ms Boston Seaport Llc | Permit type: Fire alarm | Permit status: Open | Current use: Vacld | Permit id: Efa622001 | Parcel: 0602640030 | |||||
SCORE 77 99111 Seaport Bl Boston Ma Actual address where work is to be done is at 121 seaport boulevard. Installation of a 480-v 3-phase 2000-amp temporary power system that will provide power for the construction of 121 seaport blvd. The power system will include a 400a 480v service connection every six floors power boxes every 3 floors and adequate lighting and power for all floors as per osha requirements. Client: Ms Boston Seaport Llc | Permit type: Electrical temporary service | Expiration date: October 6, 2016 | Current use: Vacld | Permit id: Ets576607 | Parcel: 0602640030 | |||||
SCORE 77 99111 Seaport Bl Boston Ma Actual address where work is to be done is 121 seaport boulevard. Provide a complete analog addressable fire detection voice evacuation alarm and control network. System will be constructed in compliance with the submitted drawings and all applicable code requirements. Client: Ms Boston Seaport Llc | Permit type: Electrical fire alarms | Expiration date: February 18, 2017 | Current use: Vacld | Permit id: Efa622001 | Parcel: 0602640030 | |||||
SCORE 77 99111 Seaport Bl Boston Ma The physical address of the project is actually 121 seaport blvd. The electrical work to be completed is comprised of the complete power lighting fire alarm and security for the proposed core and shell building. Improvements include 2 - 4000a permanent bldg services; a 1200a fire pump service; 2 - 4000a bus risers; a 300kva generator; 4 - 400a ats switches; as well as various power distribution equipment and the aforementioned systems servicing the entire building. Client: Ms Boston Seaport Llc | Permit type: Electrical permit | Expiration date: September 30, 2017 | Current use: Vacld | Permit id: E693142 | Parcel: 0602640030 | |||||
SCORE 77 742744 Columbus Av Mission Hill Ma Providing temporary power service for the construction of the proposed northeastern university - columbus avenue student apartments a 3 0 + - square foot building housing 8 student dorms. Temporary power will be provided by a 2 000a 277 480v piece of switchgear that is fed from an eversource supplied 2 500kva 13. 8kv 277 480v padmount transformer. The switchgear will inturn feed a 500kva transformer that will stepdown the voltage to 120 208v. The temporary service will be utilized during construction to power the tower crane man material hoists welders heaters lighting etc. Client: Northeastern University | Permit type: Electrical temporary service | Expiration date: December 1, 2017 | Current use: Vacld | Permit id: Ets715320 | Parcel: 0901401000 |