SCORE 82 2100 Dorchester Av Dorchester Ma 02124 Work location: intensive care unit (icu) rooms 9 10 11 & 12 work per room: 1. Install one 20 amp 102 volt hospital grade receptacle on dedicated isolated power circuit. Client: New Caritas Chr | Permit type: Electrical | Current use: Other | Permit id: E286381 | Parcel: 1605018001 | |||||
SCORE 82 2100 Dorchester Av Dorchester Ma 02124 Work location: intensive care unit (icu) rooms 9. 10 11 &12 work per room: 1. Install one cat5e cable from nrwwork switch to room. 2. Install five cat5e cables to devices installed in each room: a. Camera b. Speaker c. Elert button d. Microohone e. Lcd monitor Client: New Caritas Chr | Permit type: Electrical | Current use: Other | Permit id: Elv286390 | Parcel: 1605018001 | |||||
SCORE 82 2100 Dorchester Av Dorchester Ma 02124 Install 1 cat5e data drops from 1st floor data room to 2nd floor icu rooms 208 214 215 219 & 219 install 2 cat5e data drops to room 218 for future use. Install 5 cat 5e cables in above rooms for speaker camera monitor & e-alert button. Above project is known as phase2 e-icu project. Client: New Caritas Chr | Permit type: Low voltage | Current use: Other | Permit id: Elv411147 | Parcel: 1605018001 | |||||
SCORE 82 2100 Dorchester Av Dorchester Ma 02124 Location 2nd floor icu unit. Install one duplex fed from isolation panel in rooms 208 214 & 215. Install one gfci duplex receptacle fed from new sub-panel in rooms 216 218 & 219. Install 60 amp 120 208 volt sub-panel off of existing panel l2s2c. Client: New Caritas Chr | Permit type: Electrical | Current use: Other | Permit id: E411141 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma 02124 Work location: intensive care unit (icu) rooms 9. 11 &12 work per room: 1. Install one cat5e cable from nrwwork switch to room. 2. Install five cat5e cables to devices installed in each room: a. Camera b. Speaker c. Elert button d. Microohone e. Lcd monitor Client: New Caritas Christi Hospital | Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: Elv286390 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma 02124 Install 1 cat5e data drops from 1st floor data room to 2nd floor icu rooms 208 214 215 219 & 219 install 2 cat5e data drops to room 218 for future use. Install 5 cat 5e cables in above rooms for speaker camera monitor & e-alert button. Above project is known as phase2 e-icu project. Client: Steward Carney Hospital Inc | Permit type: Low voltage | Permit status: Expired | Current use: Other | Permit id: Elv411147 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma 02124 Location 2nd floor icu unit. Install one duplex fed from isolation panel in rooms 208 214 & 215. Install one gfci duplex receptacle fed from new sub-panel in rooms 216 218 & 219. Install amp 120/208 volt sub-panel off of existing panel l2s2c. Client: New Caritas Christi Hospital | Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E411141 | Parcel: 1605018000 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma 02124 Work location: intensive care unit (icu) rooms 9 11 & 12 work per room: 1. Install one amp 102 volt hospital grade receptacle on dedicated isolated power circuit. Client: Steward Carney Hospital Inc | Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E286381 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma Work location: intensive care unit (icu) rooms 9. 11 &12 work per room: 1. Install one cat5e cable from nrwwork switch to room. 2. Install five cat5e cables to devices installed in each room: a. Camera b. Speaker c. Elert button d. Microohone e. Lcd monitor Client: New Caritas Christi Hospital | Permit type: Electrical low voltage | Expiration date: March 17, 2014 | Current use: Other | Permit id: Elv286390 | Parcel: 1605018000 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma Work location: intensive care unit (icu) rooms 9 11 & 12 work per room: 1. Install one amp 102 volt hospital grade receptacle on dedicated isolated power circuit. Client: New Caritas Chr | Permit type: Electrical permit | Expiration date: March 17, 2014 | Current use: Other | Permit id: E286381 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma Install 1 cat5e data drops from 1st floor data room to 2nd floor icu rooms 208 214 215 219 & 219 install 2 cat5e data drops to room 218 for future use. Install 5 cat 5e cables in above rooms for speaker camera monitor & e-alert button. Above project is known as phase2 e-icu project. Client: New Caritas Chr | Permit type: Electrical low voltage | Expiration date: March 25, 2015 | Current use: Other | Permit id: Elv411147 | Parcel: 1605018001 | |||||
SCORE 82 21 Dorchester Av Dorchester Ma Location 2nd floor icu unit. Install one duplex fed from isolation panel in rooms 208 214 & 215. Install one gfci duplex receptacle fed from new sub-panel in rooms 216 218 & 219. Install amp 120/208 volt sub-panel off of existing panel l2s2c. Client: New Caritas Christi Hospital | Permit type: Electrical permit | Expiration date: March 25, 2015 | Current use: Other | Permit id: E411141 | Parcel: 1605018000 |