SCORE 82 Date: June 30, 2017 Contractor: Evcharge4u Inc Permit status: Permit issued | Permit id: 17000-01506 | |||||
SCORE 82 Unit 117 / 325 Channing Av, Unit 117, Palo Alto, Ca 94301 San Diego Ca Units 117 and 303: install two level 2 evse (one each for units 117 and 303) inside the parking garage Date: July 20, 2017 Contractor: Evcharge4u Inc Permit status: Permit issued | Permit id: 17000-01702 | |||||
SCORE 82 Unit 101 / 325 Channing Av, Unit 101, Palo Alto, Ca 94301 San Diego Ca Unit 101: residential evse - two level 2 evse located in the parking garage at spaces 12 and 13 that serve unit 101. Date: November 14, 2017 Contractor: Evcharge4u Inc Permit status: Permit issued | Permit id: 17000-02738 | |||||
SCORE 82 1 Romain St San Francisco Ca Install a nema 14- receptacle on a dedicated circuit 240volt - 50amp. 6awg copper wire. Date: April 19, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201704144835 | |||||
SCORE 82 38 23rd St San Francisco Ca Install nema 14- receptacle on dedicated circuit 240volt - 50amp below house panel in garage. Our raceway is one-inch emt our wire size 6awg copper. Date: April 15, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201704154843 | |||||
SCORE 82 229 Brannan St San Francisco Ca Install two evercharge ev-charging stations on dedicated circuit 240volt-40amp from existing ev-panel. Our raceway is one-inch emt with 6awg copper wire. Ev-panel on floor above. Date: April 14, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201704144834 | |||||
SCORE 82 406 Girard St San Francisco Ca Replace ftp disconnect 90amp for a small electrical panel with distribution for unit 406 and install nema 14- on dedicated circuit back to back in garage. Date: April 19, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201704124800 | |||||
SCORE 82 184 Maywood Dr San Francisco Ca Install new sub panel and bmw ev-charging station on a dedicated circuit 240v-40amp Date: April 10, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201704104722 | |||||
SCORE 82 Unit 0 / 1402 Kearny St San Francisco Ca Add 4 circuits to bathroom 1 switch 1 light. (please note: we are the c- contractor hired to clean up pre-existing problems on original permit:e20161019542) Date: August 17, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201708107260 | |||||
SCORE 82 449 Chenery St San Francisco Ca Installing nema 14- receptacle on dedicated circuit 240volt - 50amp raceway is romex 6 3 copper in wall. (for tesla model s) Date: August 14, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201708147309 | |||||
SCORE 82 718 Cole St San Francisco Ca Upgrade service from 125amp to 200amp and ad tesla wall connector on dedicated circuit 240volt - 90amp. Service drop ridged 2 inch with 2 wire as feeders. Date: August 28, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201708287620 | |||||
SCORE 82 Unit 12 / 229 Brannan St San Francisco Ca Install evercharge ev-charging station on dedicated circuit 208volt- 40amp raceway one-inch emt conduit with 6awg copper wires as feeders Date: December 6, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201712019620 | |||||
SCORE 82 723 Lawton St San Francisco Ca Install tesla wall connector and nema 14- receptacle near main panel garage. Tesla wall connector is on dedicated circuit 240volt ? 90amp and the nema 14- receptacle on dedicated circuit 240volt ? 50amp. Date: February 28, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201802231270 | |||||
SCORE 82 Unit 0 / 1178 Greenwich St San Francisco Ca Install tesla wall connector behind a dcc load management system so that the car when the load in the residence is less than 80%. A dedicated circuit 240volt - 40amp will feed the car and charge with 32amp our raceway one-inch conduit with 6awg copper feeders Date: February 27, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201802191152 | |||||
SCORE 82 Unit 5 / 4 Oak St San Francisco Ca Install tesla wall connector behind an rve dcc loadmanagement box with settings of 240volt-30amp breaker and 24amp charge. Raceway one-inch emt with 6awg copper wire. Date: January 20, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201801200496 | |||||
SCORE 82 106 Cordova St San Francisco Ca Install nema 14- receptacle on dedicated circuit 240v-50amp. Install 2 gfci outlets in backyard Date: January 3, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201801030133 | |||||
SCORE 82 39 Washington St San Francisco Ca Install nema 14- receptacle on dedicated circuit 240volt - 50amp our raceway one-inch emt conduit with 6awg Date: January 26, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201801060218 | |||||
SCORE 82 241 10th St San Francisco Ca Install ev-panel garage for parking spot 1-8 install ev-charging station at parking spot 1 thru 8. Date: January 8, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201801030148 | |||||
SCORE 82 Date: January 12, 2018 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201801120337 | |||||
SCORE 82 595 44th Av San Francisco Ca Install nema 14- receptacle below sub panel that is located on right side garage. Our raceway is a surface mounted one-inc electrical metal tubing (emt) and use 6awg copper wires as feeders for the dedicated circuit 240volt - 50amp from the main panel. Date: July 27, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201707246892 | |||||
SCORE 82 1 Stanford Heights Av San Francisco Ca Install nema 14- receptacle below main electrical panel (on right side garage) on dedicated circuit 240volt - 50amp. Raceway is a surface mounted one-inc electrical metal tubing (emt) 6awg copper wires as feeders. Date: July 24, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201707246890 | |||||
SCORE 82 Unit 1 / 56 Sheridan St San Francisco Ca Tap of main disconect owners unit and install small disconnect box with 60a disconnect for feed and 50a breaker for nema 14. Near parking spot. 1in emt conduit with 6awg copper wire. Receptacle for e v charging. Date: March 23, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: E201703073374 | |||||
SCORE 82 311 Waller St San Francisco Ca Install nema 14- receptacle on right side of garage below meters and panels on a dedicated circuit 240volt - 50amp. Date: March 28, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201703134096 | |||||
SCORE 82 Date: April 4, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201703244406 | |||||
SCORE 82 Unit 0 / 255 San Marcos Av San Francisco Ca Install tesla wall connector on back wall garage right from entrance door on dedicated circuit 240v - 60amp Date: March 28, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201703234351 | |||||
SCORE 82 Unit 322 / 2 Brannan St San Francisco Ca Ev- installation parking spot 322 gb-level: install evercharge ev-2 charging station on dedicated circuit 208volt - 40amp from existing ev-2 charger at spot 305 ga-level. Disconnect charger at 305 and install a small electrical panel next to charger. Behind this charger we will install the two dedicated circuits for 305 and 322 chargers. Our raceway is a 170lf surface mounted one inch electrical metal tubing emt with 6awg copper wire. Date: March 24, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201703244407 | |||||
SCORE 82 Date: May 31, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201705225561 | |||||
SCORE 82 27 Broadway San Francisco Ca Install small disconnect panel 240volt - 60amp behind the main disconnect 200amp to create space for tesla wall connector 240volt -50amp what will charge the car with 40amp. Our raceway is one inch emt with 6awg copper. Date: May 12, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705125391 | |||||
SCORE 82 Date: May 22, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705225579 | |||||
SCORE 82 Unit 378 / 451 Kansas St San Francisco Ca Install evercharge ev-charging station on dedicated circuit 240volt - 40amp. Our raceway is one-inch emt 6awg copper wire. (these charging stations are having a load management system) Date: May 9, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201705035202 | |||||
SCORE 82 Unit 2 / 142 Russ St San Francisco Ca Install small sub panel to at evcharger on unit meter disconnect. Disconnect new 100amp 65ka rated unit panel and evcharger from small sub panel electric room. Clipper creek hcs-40p with nema 14- cord nema 14- receptacle on dedicated 240volt - 50amp. The raceway is one-inch emt conduit with 6awg copper wire. Date: May 16, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705165452 | |||||
SCORE 82 229 Brannan St San Francisco Ca Install small sub panel on existing ev circuit. And rewire existing ev-charging station plus new ev charging station on load management. Date: May 10, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201705015154 | |||||
SCORE 82 27 Pierce St San Francisco Ca Clean up several outdated panel and disconnects in the basement and make it one sub panel. And install nema 14- receptacle outdoor on dedicated 240volt - 30amp circuit. Our raceway is a surface mounted one-inch emt conduit with 6awg copper wire. Date: May 16, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705165453 | |||||
SCORE 82 Date: May 22, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705225564 | |||||
SCORE 82 Unit 2 / 1 Hawthorne St San Francisco Ca Install 4 ev-charging stations in garage to realize the feeders we will install a new emt 1-1 2 inch raceway from existing ev panel to first junction box above ev-charging station. All 4 ev charging stations will have there own dedicated circuit 208volt - 40amp. Date: May 10, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705105351 | |||||
SCORE 82 Date: May 2, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201705025162 | |||||
SCORE 82 Date: November 22, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711229459 | |||||
SCORE 82 Taraval St San Francisco Ca Install tesla wall connector inside the garage on dedicated circuit 240v - 60amp Date: November 21, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711219407 | |||||
SCORE 82 Unit 102 / 8 Octavia St San Francisco Ca Installing two ev-panels (single phase) in the garage on a dedicated meter spot 208volt-125amp (1awg copper). Including 4 evercharge ev-chargers on each a dedicated circuit (6awg copper). Date: November 22, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201711139241 | |||||
SCORE 82 1556 Shrader St San Francisco Ca Install nema 14- receptacle on a dedicated 240v-50amp circuit from the main panel. Raceway is 1 inch (emt) wire size: 6awg copper. Date: November 16, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711169336 | |||||
SCORE 82 97 Parker Av San Francisco Ca Install nema 14- receptacle inside garage. Raceway is 5lf of surface mounted emt wire size: 6 awg copper. Date: November 9, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711099188 | |||||
SCORE 82 2901 21st Av San Francisco Ca Install tesla wall connector on dedicated circuit 240volt - 100amp raceway is 30lf surface mounted one-inch electrical metal tubing (emt) running from sub electrical panel and carries 3awg copper wire. Date: November 16, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711169339 | |||||
SCORE 82 2324 Pine St San Francisco Ca Install new sub panel right of meter pack. Install a tesla wall connector on a dedicated circuit 240v-60amp. Raceway to new sub panel will be 5 lf surface mounted 1 1 2 inch emt conduit wire size 3awg copper. The raceway to the tesla wall connector will be 15 lf surface mounted 1 inch emt conduit wire size 6awg copper. Date: November 6, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201711069102 | |||||
SCORE 82 Unit 100 / 72 Townsend St San Francisco Ca Install evercharge evcharger at parking spot 36 on a dedicated circuit 240volt - 40amp our run is a surface mounted one-inch emt conduit with 6awg copper wire. Date: October 25, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201710198755 | |||||
SCORE 82 Unit 16 / 229 Brannan St San Francisco Ca Install 3x evercharge ev-2 charging station on dedicated circuit 208volt - 40amp from ev panel. Our raceway is surface mounted one-inch electrical metal tubing (emt). Our wire size is 6awg copper. Date: October 25, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201710048425 | |||||
SCORE 82 Date: September 6, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201709067811 | |||||
SCORE 82 88 Townsend St San Francisco Ca Installing infrastructure ev-panels (4ea) ev charging stations from main panel (dedicated circuit208volt -200amp). 1ea relocated existing charging station on new ev-panel 1 ea main 200amp run 3 2ea sub panels 175amp 2 1ea sub panel 150amp. 2 ea new ev-charging station on new dedicated circuit 208volt-35amp 6awg copper wire Date: September 19, 2017 Contractor: Evcharge4u Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201709198092 |