SCORE

ADCOCKS SYSTEMS

ABOUT ADCOCKS SYSTEMS

Adcocks Systems specializes in:

Adcocks Systems offers services:

Based on the information received from , associated with Adcocks Systems over the past .

If you are considering hiring Adcocks Systems for your home renovation project, we recommend using our bidding system to get competitive quotes.




QUALITY


Adcocks Systems has CheckPermit score of which places them above % of local contractors.
We usually recommend hiring a contractor with a rank of 75 or above.

ACTIVITY



AVERAGE PROJECT COST



PERMITS VALUATION



PROJECTS PER TOWN:



SERVICES
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
PROJECT IMAGES



RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
76
28 Quebec St Nw, Washington, Dc 20008
Fire alarm the building at 28 quebec street, nw has a notifier 10 fire alarm control panel that has developed a permanent internal fault. The existing panel is no longer supported by the manufacturer and replacement parts are not available anymore. Our scope of work in relation to the fire alarm system is to, on an emergency basis, replace the existing fire alarm control panel with a new notifier 6 fire alarm control panel capable of matching all functions of the existing panel.
Date:  January 10, 2013
Contractor: Adcocks Systems

Client: Community Realty Company | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1302586
2013/01/1007628 Quebec St Nw, Washington, Dc 20008Adcocks Systems
SCORE
76
15 K St Nw, Washington, Dc 20005
Head end fire alarm control panel repair it is the owners intention to repair the existing fire alarm system. The existing notifier am-20 cpu shall be replaced with a new notifier nfs2-30 cpu for communication compatibility purposes. The new notifier nfs2-30 cpu is fully compatible with all of the existing equipment, i. E., power supplies, addressable field devices, etc., associated with the notifier am-20 and is the u. L. Listed manufacturer replacement for the am-20 panel. The existing non-supported xp8-c notification cards shall be replaced with new xp6-c notification cards that are the u. L. Compatible replacement equivalents. The existing sequence of operation shall remain unchanged and the existing field initiating and notification devices shall remain unchanged. Work shall be performed in accordance with dcm12j existing building code supplement chapter 5j and the 2006 edition of the international existing building code chapter 5 repairs, section 503 fire alarm. The existing level o
Date:  May 20, 2013
Contractor: Adcocks Systems

Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1306993
2013/05/2007615 K St Nw, Washington, Dc 20005Adcocks Systems
SCORE
76
2 Michigan Ave Ne, Washington, Dc 20017
Installation of fire alarm control panel, notification and initiating devices
Date:  June 28, 2013
Contractor: Adcocks Systems

Client: Horning Brothers | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1306689
2013/06/280762 Michigan Ave Ne, Washington, Dc 20017Adcocks Systems
SCORE
76
19 K St Nw, Washington, Dc 20006
Fire alarm replace fire alarm control panel and associated devices.
Date:  March 7, 2014
Contractor: Adcocks Systems

Client: Hines | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1403600
2014/03/0707619 K St Nw, Washington, Dc 20006Adcocks Systems
SCORE
76
1 Thomas Cir Nw, Washington, Dc 20005
Replace the existing fire alarm system with voice evacuation.
Date:  December 18, 2014
Contractor: Adcocks Systems

Client: Thomas Circle Cf Llc | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1501023
2014/12/180761 Thomas Cir Nw, Washington, Dc 20005Adcocks Systems
SCORE
76
2001 Pennsylvania Ave Nw, Washington, Dc 20006
Perform a fire alarm system replacement inclusive of initiating and monitoring devices and notification devices within the core and common areas.
Date:  October 7, 2015
Contractor: Adcocks Systems

Client: Carr Properties | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1511294
2015/10/070762001 Pennsylvania Ave Nw, Washington, Dc 20006Adcocks Systems
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.