Building Permits at M Street Se Under Pennsylvania Avenue Se Washington DC


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with M Street Se Under Pennsylvania Avenue Se Washington DC over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
One (1) geotechnical boring that is 8 inches in diameter and approximately 1 feet deep; located south of m street se and to the east of the intersection b/w m street se and water street se.
Date:  May 21, 2010

Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: August 27, 2010 | Permit id: Pa55624
2010/05/21095M Street Se Under Pennsylvania Avenue Se Washington Dc
Two (2) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. The borings are located to the south of m street se, east of where it intersects pennsylvania avenue. One boring (arc-12) is located in an unpaved parking area and one boring (arc-13) is located on a paved parking area; both are located south of lot 0801, square 1080e.
Date:  July 22, 2010

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: January 1, 2011 | Permit id: Pa56767
2010/07/22095M Street Se Under Pennsylvania Avenue Se Washington Dc
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; four (4) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. Cs18c-05 is in a grassed area to the north of the westbound lanes of southeast freeway; cs18c-06 and cs18c-07 are in the eastbound lanes of southeast freeway; and cs18c-08 is in a grassed area just north of m street se; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050
Date:  November 4, 2010

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: May 29, 2011 | Permit id: Pa58441
2010/11/04095M Street Se Under Pennsylvania Avenue Se Washington Dc
Excavate two (2) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. The borings are located to the south of m street se, east of where it intersects pennsylvania avenue. One boring (arc-12) is located in an unpaved parking area and one boring (arc-13) is located on a paved parking area; both are located south of lot 0801, square 1080e. Attached plans and conditions are part of this permit. A separate permit will be required if steel plates are utilized. Hours permitted to work are between 9: am to 3: pm monday thru friday.
Date:  December 15, 2010

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: February 15, 2011 | Permit id: Pa56767-R1
2010/12/15095M Street Se Under Pennsylvania Avenue Se Washington Dc
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; two (2) geotechnical borings identified as arc-22 and arc-23 that are approximately 8 inches in diameter and approximately 1 feet deep; a monitoring well or vibrating piezometer may be installed in the borings; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050
Date:  January 25, 2011

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: August 13, 2011 | Permit id: Pa59665
2011/01/25095M Street Se Under Pennsylvania Avenue Se Washington Dc
SCORE
100
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; four (4) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. Cs18c-05 is in a grassed area to the north of the westbound lanes of southeast freeway; cs18c-06 and cs18c-07 are in the eastbound lanes of southeast freeway; and cs18c-08 is in a grassed area just north of m street se; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050
Date:  November 4, 2010
Contractor: E2cr Inc

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: May 29, 2011 | Permit id: Pa58441
2010/11/040100M Street Se Under Pennsylvania Avenue Se Washington DcE2cr Inc
SCORE
100
Excavate two (2) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. The borings are located to the south of m street se, east of where it intersects pennsylvania avenue. One boring (arc-12) is located in an unpaved parking area and one boring (arc-13) is located on a paved parking area; both are located south of lot 0801, square 1080e. Attached plans and conditions are part of this permit. A separate permit will be required if steel plates are utilized. Hours permitted to work are between 9: am to 3: pm monday thru friday.
Date:  December 15, 2010
Contractor: E2cr Inc

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: February 15, 2011 | Permit id: Pa56767-R1
2010/12/150100M Street Se Under Pennsylvania Avenue Se Washington DcE2cr Inc
SCORE
100
One (1) geotechnical boring that is 8 inches in diameter and approximately 1 feet deep; located south of m street se and to the east of the intersection b w m street se and water street se.
Date:  May 21, 2010
Contractor: E2cr Inc

Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: August 27, 2010 | Permit id: Pa55624
2010/05/210100M Street Se Under Pennsylvania Avenue Se Washington DcE2cr Inc
SCORE
98
Two (2) soil borings by either direct-push or auger methods that are approximately 6-inches in diameter and feet deep. The borings are located along m street se, to the east of the intersection b/w m street se and water street se.
Date:  May 24, 2010
Contractor: Urs Corporation

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: August 4, 2010 | Permit id: Pa55645
2010/05/24098M Street Se Under Pennsylvania Avenue Se Washington DcUrs Corporation
SCORE
100
Two (2) geotechnical borings that are approximately 8 inches in diameter and approximately 1 feet deep. The borings are located to the south of m street se, east of where it intersects pennsylvania avenue. One boring (arc-12) is located in an unpaved parking area and one boring (arc-13) is located on a paved parking area; both are located south of lot 0801, square 1080e.
Date:  July 22, 2010
Contractor: E2cr Inc

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: January 1, 2011 | Permit id: Pa56767
2010/07/220100M Street Se Under Pennsylvania Avenue Se Washington DcE2cr Inc
SCORE
100
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; two (2) geotechnical borings identified as arc-22 and arc-23 that are approximately 8 inches in diameter and approximately 1 feet deep; a monitoring well or vibrating piezometer may be installed in the borings; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050
Date:  January 25, 2011
Contractor: E2cr Inc

Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: August 13, 2011 | Permit id: Pa59665
2011/01/250100M Street Se Under Pennsylvania Avenue Se Washington DcE2cr Inc