Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Relocation of existing sprinkler heads on the 3rd level approximately (6) total heads to be relocated coordinate with building management so that only one floor is impaired in the building at any time Permit status: Na | Permit id: Sprk63876 | |||||
Temporary bagging of smoke detectors for dust control during construction Permit status: Na | Permit id: Bsd87045 | |||||
Cutting burning &; welding;to replace floor flanges on hot water system bfd paid detail required Permit status: Na | Permit id: Cbw214228 | |||||
Welding only of new diamond plate on existing plate bfd paid detail required Permit status: Na | Permit id: Cbw374990 | |||||
SCORE 88 Welding / cutting / brazing of existing piping to include cutting back installation of valves and welding cap onto steam pipe;for replacement of cagewasher;(dpl) bfd paid detail required Permit status: Na | Permit id: Cbw444246 | |||||
Installation of pane Permit status: Na | Permit id: Chm131798 | |||||
Cutting &; welding of black iron pipe bfd paid detail required Permit status: Na | Permit id: Cbw24637 | |||||
Temporary bagging of smoke detectors for dust control during construction Permit status: Na | Permit id: Bsd112935 | |||||
Welding studs to apparatus using ncd discharge system for modifications to irridator to harden / soften equipment (dpl) bfd paid detail required Permit status: Na | Permit id: Cbw11008 | |||||
Welding for modifications to (1bl-437c) blood irridiator including welding of studs to apparatus to harden / fasten equipment to concrete floor bfd paid detail required Permit status: Na | Permit id: Cbw91670 | |||||
SCORE 100 Electrical preventive de-energized maintenance on main switchgear Permit type: Annual maintenance | Current use: Comm | Permit id: E194095 | |||||
Relocation of existing sprinkler heads on the 3rd level approximately (6) total heads to be relocated coordinate with building management so that only one floor is impaired in the building at any time Permit type: Bfd sprinkler system | Permit id: Sprk63876 | |||||
Welding for installation of new boiler controls on boiler to accommodate boiler controls upgrade (dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw543484 | |||||
Temporary bagging of smoke detectors for dust control during construction Permit type: Bfd bag smoke detectors | Permit id: Bsd87045 | |||||
Cutting burning &; welding;to replace floor flanges on hot water system bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw214228 | |||||
SCORE 100 Electrical preventive de-energized maintenance on main switchgear Permit type: Electrical permit | Expiration date: April 24, 2013 | Current use: Comm | Permit id: E194095 | |||||
Welding only of new diamond plate on existing plate bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw374990 | |||||
Bfd chemist certificate proces Permit id: Chm131798 | |||||
Cutting &; welding of black iron pipe bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw24637 | |||||
Temporary bagging of smoke detectors for dust control during construction Permit type: Bfd bag smoke detectors | Permit id: Bsd112935 | |||||
Welding studs to apparatus using ncd discharge system for modifications to irridator to harden / soften equipment (dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw11008 | |||||
Welding for modifications to (1bl-437c) blood irridiator including welding of studs to apparatus to harden / fasten equipment to concrete floor bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw91670 | |||||
Cutting welding burning grinding brazing on chilled water piping to support mounted chillers dpl 5 1 16 bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw562841 | |||||
The kitchen suppression system shall be connected to building fire alarm system Permit type: Bfd sprinkler system | Permit id: Sprk605831 | |||||
Cutting burning welding grinding brazing for installation of chilled water piping to support roof mounted chillers dpl 8 7 16 bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw612820 | |||||
Cutting burning welding to replace steam condensate piping &; valves; that are leaking dpl 11 30 16 bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw622992 | |||||
Welding studs to apparatus using ncd discharge system for modifications to irridator to harden soften equipment (dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw11008 | |||||
Welding for modifications to (1bl-437c) blood irridiator including welding of studs to apparatus to harden fasten equipment to concrete floor bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw91670 | |||||
SCORE 66 Cut refrigerant piping to coldroom condensing units. Reconnect to condensing unit at higher elevation due to roofing project. Lines 1" copper and smaller. (dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw709991 | |||||
SCORE 56 Cutting welding &; grinding of pinhole leak in carbon steel plate (dpl) Permit type: Bfd cutting-burning-welding | Permit id: Cbw645054 | |||||
SCORE 86 Temporary bagging of smoke detectors Permit type: Bfd bag smoke detectors | Permit id: Bsd710229 | |||||
SCORE 82 The existing metal roof decking needs to be cut away in order to install tube steel posts directly to the structural steel for the installation of the new ships ladder extensions. The method of opening will be cutting with an angle grinder (dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw727953 | |||||
SCORE 88 Welding / cutting / brazing of existing piping to include cutting back installation of valves and welding cap onto steam pipe;for replacement of cagewasher;(dpl) bfd paid detail required Permit type: Bfd cutting-burning-welding | Permit id: Cbw444246 |