Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 93 Capping existing lateral and removing curb trap pa20160900682 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: March 30, 2016 Contractor: Michael Fugarino Client: Alpha United Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 3, 2016 | Permit id: 680280 | |||||
Complete demolition of existing 3 story sfd Date: April 13, 2016 Client: Alpha United Lp | Permit type: Zoning/use permit | Permit status: Completed | Completion date: April 13, 2016 | Permit id: 680615 | |||||
For the complete demoltion of an attached three-story structure. Full sidewalk and street closure required as reflected on approved site plan and in accordance with section 3306 of the ibc (safety zone is 16. 25 feet). Separate street closure permit required prior to start of work. Any deviation will require an amended building permit. 21 day notification to adjacent property owners to be waived as per section a-303. 2 of the phila administrative code (dangerous case). Date: April 13, 2016 Client: Alpha United Lp | Permit type: Demolition permit | Permit status: Completed | Completion date: August 30, 2016 | Permit id: 680617 | |||||
SCORE 96 Install 92% 60,0 btu gas furnace with 2 ton 13 seer a c in basement 1st fl,92% 60,0 btu gas furnace with 2 1 2 ton 13 seer a c on 2nd and 3rd floor with full duct work. Date: December 21, 2016 Contractor: Balance Point Heating And Air Client: Alpha United Lp | Permit type: Mechanical permit | Permit status: Completed | Completion date: July 11, 2017 | Permit id: 745077 | |||||
SCORE 100 For the installation of an automatic sprinkler system with a 1" combined fire & domestic service line for a three (3) story single family dwelling with rooftop structure. System installation in accordance with nfpa 13d. Date: November 4, 2016 Contractor: Oneida Fire Protection Client: Alpha United Lp | Permit type: Suppression permit | Permit status: Completed | Completion date: July 11, 2017 | Permit id: 732877 | |||||
SCORE 93 Install 3 wc,3 vanity,1 shower,1 tub,1 washer,1 kitchen sink,stack,main drain,curb trap,lateral and water service pa20163150281 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: November 16, 2016 Contractor: Michael Fugarino Client: Alpha United Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: July 11, 2017 | Permit id: 731294 | |||||
SCORE 100 Install a new 2 amp svc complete wiring including circuits, outlets, switches, lights, eight 120v smokes and 6 phone cables as per 2008 nec (cc district) Date: September 28, 2016 Contractor: Sean Kearns Client: Alpha United Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: July 6, 2017 | Permit id: 725247 | |||||
Erection of a three story single family dwelling with cellar, roof deck & pilot house to access roof deck as per plans Date: June 29, 2016 Client: Alpha United Lp | Permit type: New construction permit | Permit status: Completed | Completion date: July 19, 2017 | Permit id: 702036 |