Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Warlick, leigh Date: January 23, 2013 Permit status: Closed | Permit id: 12-05787 | |||||
SCORE 95 Warlick, leigh Client: Warlick, Leigh | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 12-05787 | Parcel: 95783 | |||||
SCORE 100 Warlick, leigh Client: Warlick, Leigh | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 12-05787 | Parcel: 95783 | |||||
October 8, 2012 5:18:25 pm rhurley. Move existing home and setup in mobile home park; wellington estates;rlh; november 21, 2012 2:50:36 pm jfortner. Move existing home and setup in mobile home park; wellington estates; october 9, 2012 9:59:23 am rhurley. To request residential inspections call 828-redacted phone number manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 12-05787 | Parcel: 95783 | |||||
Warlick, leigh Date: January 23, 2013 Value: $3,725 Permit type: Residential | Permit status: Closed | Permit id: 12-05787 | |||||
October 8, 2012 5:18:25 pm rhurley. Move existing home and setup in mobile home park; wellington estates;rlh; november 21, 2012 2:50:36 pm jfortner. Move existing home and setup in mobile home park; wellington estates; october 9, 2012 9:59:23 am rhurley. To request residential inspections call 828-redacted phone number manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Date: January 23, 2013 Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 12-05787 | Parcel: 95783 |