Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Suppression permit Date: June 17, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 348198 | |||||
Electrical permit Date: February 17, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 325492 | |||||
Alteration permit Date: August 17, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 416123 | |||||
Suppression permit Date: November 4, 2014 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 565934 | |||||
Electrical permit Date: June 7, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Active | Permit id: 690399 | |||||
Suppression permit Date: November 6, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 436442 | |||||
Suppression permit Date: September 1, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 635807 | |||||
Electrical permit Date: April 21, 2008 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 141212 | |||||
Mechanical permit Date: April 13, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Active | Permit id: 677319 | |||||
Plumbing permit Date: September 14, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 634483 | |||||
Plumbing permit Date: August 31, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 361025 | |||||
Electrical permit Date: October 2, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 430555 | |||||
Plumbing permit Date: June 14, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Active | Permit id: 692713 | |||||
Alteration permit Date: September 2, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 627873 | |||||
Electrical permit Date: December 21, 2010 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 311952 | |||||
Suppression permit Date: May 4, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Active | Permit id: 689380 | |||||
Plumbing permit Date: November 13, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 434962 | |||||
Electrical permit Date: December 11, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 649258 | |||||
Electrical permit Date: November 4, 2014 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 565454 | |||||
Alteration permit Date: March 16, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Active | Permit id: 676456 | |||||
Suppression permit Date: August 13, 2008 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 164899 | |||||
Mechanical permit Date: October 1, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 635356 | |||||
Electrical permit Date: September 11, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 631516 | |||||
Alteration permit Date: September 2, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 627873 | |||||
Plumbing permit Date: June 14, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 692713 | |||||
Suppression permit Date: August 27, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 424245 | |||||
Mechanical permit Date: October 1, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 635356 | |||||
Plumbing permit Date: September 14, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 634483 | |||||
Electrical permit Date: October 2, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 430555 | |||||
Suppression permit Date: November 4, 2014 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 565934 | |||||
Mechanical permit Date: April 13, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 677319 | |||||
Suppression permit Date: June 17, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 348198 | |||||
Suppression permit Date: September 1, 2015 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 635807 | |||||
Suppression permit Date: August 13, 2008 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 164899 | |||||
Electrical permit Date: November 4, 2014 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 565454 | |||||
Plumbing permit Date: November 13, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 434962 | |||||
Plumbing permit Date: August 31, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 361025 | |||||
Alteration permit Date: August 17, 2012 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 416123 | |||||
Electrical permit Date: November 16, 2011 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 373917 | |||||
Alteration permit Date: March 16, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 676456 | |||||
Electrical permit Date: December 21, 2010 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 311952 | |||||
Electrical permit Date: April 21, 2008 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 141212 | |||||
Suppression permit Date: May 4, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Completed | Permit id: 689380 | |||||
Electrical permit Date: April 12, 2016 Client: Tr Mission Of St Vincent De Paul | Permit status: Expired | Permit id: 676032 | |||||
SCORE 100 Replace existing 4" reliable model gg swing check valve. Replace like in kind on existing system. Date: November 6, 2012 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: January 2, 2013 | Permit id: 436442 | |||||
SCORE 100 Install 6 sprinklers escctcheons. Install 3 water guages and 1 air guage. Install 3 dry stad pipe signs and 1 fdc auto sprinkler sign. Replace 4" flow switch. Date: August 27, 2012 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: June 10, 2014 | Permit id: 424242 | |||||
SCORE 100 Relocate sprinkler heads to accomodate new ceiling layout Date: August 27, 2012 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: January 2, 2013 | Permit id: 424245 | |||||
SCORE 100 Reroute conduit on ground fl to 4 hole next to the alters. Wires will be disconnected and landed in a junction box run into space above ceiling to reconnect to system as per 2008 nec and nfpa72 (church school) Date: September 14, 2012 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: October 11, 2012 | Permit id: 427441 | |||||
SCORE 100 Replacing devices on the existing approved fire alarm system in renovated area as per nfpa72 (north district) Date: June 7, 2016 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Expired | Completion date: June 7, 2016 | Permit id: 690399 | |||||
SCORE 65 Alteration: interior plumbing for phase ii of the 2nd floor of a nursing & medical care center.. The installation will comply with the philadelphia plumbing code, 2004. Date: June 14, 2016 Contractor: Ajb Mechanical Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Completed | Completion date: December 22, 2016 | Permit id: 692713 | |||||
SCORE 93 Keystone will install 3 addressable photo smoke detectors and a conventional heat,detector in the new elevator lobby, the heat detector will be monitored by the module, three new relay module will be installed which will serve as primary,alternate and fire hat for the new elevator as per 2008 nec Date: December 21, 2010 Contractor: John Lawlor Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: January 14, 2011 | Permit id: 311952 | |||||
SCORE 90 Hallway & room renovations & general fixture, switch & duplex receptacle relocations & replacement as per nec 2008 north district Date: September 11, 2015 Contractor: Ronald Dolan Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: March 7, 2016 | Permit id: 631516 | |||||
SCORE 65 Interior plumbing alterations fixture replacement to existing nursing and medical care facility on the second floor per the approved plans - water filtration chiller must be protected against backflow by an approved method listed in table 608. 1 of the 2009 ipc (international plumbing code) Date: September 14, 2015 Contractor: Ajb Mechanical Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Completed | Completion date: March 7, 2016 | Permit id: 634483 | |||||
SCORE 99 Level ii interior alterations (no change of occupancy) to existing nursing and medical care facility on the second floor of an existing building as per approved plans. Existing building sprinklered. Separate permits required for any mep or fire suppression work Date: March 21, 2017 Contractor: R C Titter Constr Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Alteration permit | Permit status: Completed | Completion date: August 7, 2017 | Permit id: 763827 | |||||
SCORE 93 Renovations of 4th fl resident rooms 401 to 409 (north dist) Date: April 21, 2008 Contractor: John Lawlor Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: September 2, 2008 | Permit id: 141212 | |||||
SCORE 100 Supply and install a replacement power supply and surge suppressor to replace faulty equipment as per nfpa-72.(north dist)(used as a seminary) Date: November 16, 2011 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: February 17, 2012 | Permit id: 373917 | |||||
SCORE 99 For interior alteration to existing first floor as per plans. Electrical, plumbing and mechanical permits still required. Date: August 17, 2012 Contractor: R C Titter Constr Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Alteration permit | Permit status: Completed | Completion date: June 2, 2014 | Permit id: 416123 | |||||
SCORE 99 Level ii interior alterations (no change of occupancy) to existing nursing and medical care facility on the second floor of an existing building as per approved plans. Existing building sprinklered. Separate permits required for any mep or fire suppression work Date: September 2, 2015 Contractor: R C Titter Constr Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Alteration permit | Permit status: Expired | Completion date: March 2, 2016 | Permit id: 627873 | |||||
SCORE 100 Replace existing ansul system with new ansul system within kitchen area of a church. Date: April 14, 2011 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: June 23, 2012 | Permit id: 329534 | |||||
SCORE 100 Replace (1) fivalco firecheck valve for fire pump in seminary. Date: June 17, 2011 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: September 1, 2011 | Permit id: 348198 | |||||
SCORE 99 Level ii interior alterations (no change of occupancy) to existing nursing and medical care facility on the second floor (phase 2) of an existing building as per approved plans. Existing building sprinklered. Separate permits required for any mep or fire suppression work Date: March 16, 2016 Contractor: R C Titter Constr Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Alteration permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 676456 | |||||
SCORE 88 Relocate (75) exsiting sprinkler heads on the 2nd floor to accommodate reno Date: May 4, 2016 Contractor: Keystone Fire Protection Co Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: December 8, 2016 | Permit id: 689380 | |||||
SCORE 88 Relocation of 29 sprinkler heads Date: April 12, 2017 Contractor: Keystone Fire Protection Co Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: September 28, 2017 | Permit id: 774624 | |||||
SCORE 100 For the installation of a fire suppression system for partial basement and first floor level of an existing religious assembly, proposed fire suppression system to tie in to existing fire supression system. System serviced by an existing four inch fire service line with an existing back flow preventer assembly. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire supression system to be installed in accordance with nfpa 13. Separate permits required for electrical and plumbing work. Date: November 4, 2014 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: February 12, 2015 | Permit id: 565934 | |||||
SCORE 100 Relocate existing pendent sprinkler heads into drop ceiling on the existing 1st floor Date: September 1, 2015 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: February 26, 2016 | Permit id: 635807 | |||||
SCORE 56 Alterations: interior plumbing - the installation will comply with the philadelphia plumbing 2004 Date: June 13, 2017 Contractor: R F Bondurant Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Active | Completion date: June 13, 2017 | Permit id: 763318 | |||||
SCORE 99 Interior demolition of existing mechanical system. For the installation of heat pumps, registers diffusers, limited supply exhaust ductwork, supports, and all other work as per approved plans. Separate permit required for any electrical and plumbing work. Date: March 7, 2017 Contractor: Ja Smith Heating And Ac Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Mechanical permit | Permit status: Completed | Completion date: August 7, 2017 | Permit id: 761138 | |||||
SCORE 90 Hallway and room renovations general fixtures,switches and duplex relocation and replacement (health care) Date: April 3, 2017 Contractor: Ronald Dolan Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: August 1, 2017 | Permit id: 761170 | |||||
SCORE 100 An area in the second floor is being renovated. We are placing the devices on the existing approved fire alarm system in the renovated area per nfpa 72 (nursing home) Date: December 11, 2015 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Completed | Completion date: June 3, 2016 | Permit id: 649258 | |||||
SCORE 99 Interior demolition of mechanical work. For the installation of water source heat pump units, supply exhaust ductwork, and registers diffusers as per approved plans. See ap#676456 for alterations permit. Date: April 13, 2016 Contractor: Ja Smith Heating And Ac Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Mechanical permit | Permit status: Completed | Completion date: December 8, 2016 | Permit id: 677319 | |||||
SCORE 90 Hallway and room renovations- general fixture switch and duplex relocation and replacement per 2008 nec (health care facility)north district Date: April 12, 2016 Contractor: Ronald Dolan Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Expired | Completion date: April 12, 2016 | Permit id: 676032 | |||||
SCORE 100 Install air sampling detector system in the heritage room on the first floor as per 2008 nec (north district) Date: November 4, 2014 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Expired | Completion date: November 4, 2014 | Permit id: 565454 | |||||
SCORE 99 Interior mechanical demolition work. Hvac work to include installation of 11 water source heat pumps units, (31) registers and diffusers, and (2) dryer exhausts, and all minor associated work as per approved plans. Separate permit required for any electrical and plumbing work. All mechcanical work shall be in accordance with approved floor layout of ap#627873. Date: October 1, 2015 Contractor: Ja Smith Heating And Ac Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Mechanical permit | Permit status: Completed | Completion date: March 7, 2016 | Permit id: 635356 | |||||
SCORE 100 Install a lavatory Date: November 13, 2012 Contractor: Joseph Giannone, Inc Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Completed | Completion date: January 2, 2013 | Permit id: 434962 | |||||
SCORE 100 Replace existing lighting fixtures with energy efficient fixtures one for one throughout library, lounge and lobby corridor, lights to operate with existing switches as per 2008 nec (seminary) no additional wiring Date: October 2, 2012 Contractor: Thompson Electric Llc Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Expired | Completion date: October 2, 2012 | Permit id: 430555 | |||||
SCORE 95 Replace house trap and fai pa1#20112421033 Date: August 31, 2011 Contractor: Roto Rooter Services Company Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Completed | Completion date: June 16, 2012 | Permit id: 361025 | |||||
SCORE 95 Replace lateral in street. Pa1#20112441411 Date: September 1, 2011 Contractor: Roto Rooter Services Company Client: Tr Mission Of St Vincent De Paul | Permit type: Plumbing permit | Permit status: Completed | Completion date: June 16, 2012 | Permit id: 361313 | |||||
SCORE 100 New relocated sprinkler heads, new fire pump Date: August 13, 2008 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Suppression permit | Permit status: Completed | Completion date: September 16, 2008 | Permit id: 164899 | |||||
SCORE 100 Repair permit only: keystone fire protection proposes to relocate 1 smk detector to better protect the new office space, bldg fire alarm system is existing. Upon completion keystone will fill out appropriate city of philadelphia certifications Date: February 17, 2011 Contractor: Keystone Fire Protection Client: Tr Mission Of St Vincent De Paul | Permit type: Electrical permit | Permit status: Expired | Completion date: March 31, 2011 | Permit id: 325492 |