Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 95 Add new fire alarm system. Permit is for mechanical venting and associated electrical. 1834sf Client: Corporatio Ball | Applicant: Howell Construction | Permit type: Building, electrical | Permit status: N&v | Current use: Research & deve | |||||
SCORE 100 Install 7 foot high fence to enclose generator. Reference permit number pmt2000-03689 for drawings and review materials. Date: September 20, 2000 Contractor: Alta Milla Electric Corp Client: Ball Corporation | Applicant: Alta Milla Electric Corp | Permit type: Fence | Permit status: Cmp | Completion date: March 7, 2001 | Current use: Manufacturing, | |||||
SCORE 100 Install emergency generator. Fence screening is on separate permit number pmt2000-03691. Date: September 20, 2000 Contractor: Alta Milla Electric Corp Client: Ball | Applicant: Alta Milla Electric Corp | Permit type: Electrical | Permit status: N&v | Current use: Manufacturing, | |||||
SCORE 56 Installation of split system chiller unit to cool computer room. Date: September 25, 2007 Contractor: John Sotak Client: Corporatio Ball | Applicant: John Sotak | Permit type: Electrical, mechanic | Permit status: Cmp | Completion date: December 27, 2007 | Current use: Research & deve | |||||
SCORE 66 Tenant remodel of 2186 sf, add partition wall to existing conference room area, and convert storage area to a humidified electronics r & d lab. Client: Corporatio Ball | Applicant: Corporatio Ball | Permit type: Building, electrical | Permit status: Cmp | Completion date: June 30, 2008 | Current use: Research & deve | |||||
SCORE 98 Tennant finish sprinkler ball aerospace Date: May 2, 2008 Contractor: L. Nothhaft And Son Inc Client: Corporatio Ball | Applicant: L. Nothhaft & Son, Inc. | Permit type: Fire | Permit status: Cmp | Completion date: June 2, 2009 | Current use: Office - techni | |||||
SCORE 98 Tennant finish sprinkler ball aerospace 4th fl remodel Date: May 21, 2010 Contractor: L. Nothhaft And Son Inc Client: Corporatio Ball | Applicant: L. Nothhaft & Son, Inc. | Permit type: Fire | Permit status: Cmp | Completion date: February 4, 2011 | Current use: Office - techni | |||||
SCORE 95 Tennant finish sprinkler for mission operation center 5th floor Date: July 9, 2010 Contractor: L Nothhaft And Son Inc Client: Corporatio Ball | Applicant: L Nothhaft & Son Inc | Permit type: Fire | Permit status: Iss | Current use: Office - techni | |||||
SCORE 95 Remodel of 1,925 square feet on tech tower 5th floor. To include demolition of vault and construction of new office space. Client: Corporatio Ball | Applicant: Howell Construction | Permit type: Building, electrical | Permit status: Cmp | Completion date: February 21, 2014 | Current use: Manufacturing, | |||||
SCORE 95 Provide temperature and humidity control in existing silicone lab. To include installation of new fcu rcu on roof for temperature and humidity control. Installation of door seals and new ceiling tile. Client: Corporatio Ball | Applicant: Howell Construction | Permit type: Building, electrical | Permit status: N&v | Current use: Manufacturing, | |||||
SCORE 100 Bore accross commerce to place 2inch fiber conduit job# 1223u27-aqcb Date: December 2, 2011 Contractor: Qwest Comm Centurylink Client: Corporatio Ball | Applicant: Qwest Comm/centurylink | Permit type: Right-of-way | Permit status: Iss | Current use: Research & deve | |||||
SCORE 62 Install 2-1inch conduits for purpose of relocating ball aerospace sign. We will be able to keep all our vehicles out of the street Date: August 21, 2012 Contractor: Underground Specialties Client: Corporatio Ball | Applicant: Underground Specialties | Permit type: Right-of-way | Permit status: Iss | Current use: Office - admini | |||||
SCORE 89 Installation of a 7foot tall free-standing internally illuminated monument sign for inchball aerospace. Inch to be located on the southwest corner of this parcel (ne corner of intersection). Electrical work by separate permit and separate contractor. Portion of support structure that exeeds the minimum required for support of the sign is included in area calculation. Setback 10foot from property line adjacent to commerce and 13foot from property line adjacent to arapahoe. Date: January 11, 2013 Contractor: Cisco Signs Inc Client: Corporatio Ball | Applicant: Cisco Signs Inc | Permit type: Sign | Permit status: Cmp | Completion date: February 5, 2013 | Current use: Research & deve | |||||
SCORE 91 Demoliton of exsiting cooling tower and foundation, and replacement with new foundation and cooling tower (in same location). Client: Corporatio Ball | Applicant: Sun Const & Facility Service Inc | Permit type: Building, electrical | Permit status: Cmp | Completion date: May 30, 2014 | Current use: Research & deve | |||||
SCORE 91 Tenant interior remodel to convert laboraory rooms into 5 laboratory rooms. Client: Corporatio Ball | Applicant: Sun Const & Facility Service Inc | Permit type: Building, electrical | Permit status: Cmp | Completion date: March 18, 2014 | Current use: Research & deve | |||||
SCORE 100 Replacement and relocation of exterior transformer. Transformer is located on east side of 5001 arapahoe. Date: October 2, 2014 Contractor: Kenny Electric Service Inc Client: Corporatio Ball | Applicant: Kenny Electric Service, Inc | Permit type: Electrical | Permit status: Cmp | Completion date: December 5, 2014 | Current use: Research & deve | |||||
SCORE 92 For inchball aerospaceinch, new 12inch concrete slab to support new transformer (under separate permit), reaise existing door 8inch, and install new interior door. Client: Corporatio Ball | Applicant: Sun Construction & Design Serv, Inc | Permit type: Building | Permit status: Cmp | Completion date: March 19, 2015 | Current use: Research & deve | |||||
SCORE 91 Demoliton of exsiting cooling tower and foundation, and replacement with new foundation and cooling tower (in same location). Client: Corporatio Ball | Permit type: Building, electrical, mechanical, sitework | Permit status: Cmp | Completion date: May 30, 2014 | Current use: Research & development, existing, shop, | Permit id: Pmt2013-06620 | |||||
SCORE 91 Tenant interior remodel to convert laboraory rooms into 5 laboratory rooms. Client: Corporatio Ball | Permit type: Building, electrical, mechanical | Permit status: Cmp | Completion date: March 18, 2014 | Current use: Research & development, tenant remodel | Permit id: Pmt2014-00215 | |||||
SCORE 95 Replacement and relocation of exterior transformer. Transformer is located on east side of 5001 arapahoe. Client: Corporatio Ball | Permit type: Electrical | Permit status: Cmp | Completion date: December 5, 2014 | Current use: Research & development, existing | Permit id: Pmt2014-04110 | |||||
SCORE 95 For inchball aerospaceinch, new 12inch concrete slab to support new transformer (under separate permit), reaise existing door 8inch, and install new interior door. Client: Corporatio Ball | Permit type: Building | Permit status: Cmp | Completion date: March 19, 2015 | Current use: Research & development, remodel | Permit id: Pmt2014-04629 | |||||
SCORE 89 Installation of a 7foot tall free-standing internally illuminated monument sign for inchball aerospace. Inch to be located on the southwest corner of this parcel (ne corner of intersection). Electrical work by separate permit and separate contractor. Portion of support structure that exeeds the minimum required for support of the sign is included in area calculation. Setback 10foot from property line adjacent to commerce and 13foot from property line adjacent to arapahoe. Client: Corporatio Ball | Permit type: Sign | Permit status: Cmp | Completion date: February 5, 2013 | Current use: Research & development, existing | Permit id: Pmt2012-05705 | |||||
SCORE 98 Tennant finish sprinkler ball aerospace 4th fl remodel Client: Corporatio Ball | Permit type: Fire | Permit status: Cmp | Completion date: February 4, 2011 | Current use: Office - technical, existing | Permit id: Pmt2010-01950 | |||||
SCORE 95 Tennant finish sprinkler for mission operation center 5th floor Client: Corporatio Ball | Permit type: Fire | Permit status: Iss | Current use: Office - technical, existing | Permit id: Pmt2010-02683 | |||||
SCORE 95 Remodel of 1,925 square feet on tech tower 5th floor. To include demolition of vault and construction of new office space. Client: Corporatio Ball | Permit type: Building, electrical, mechanical, plumbing | Permit status: Cmp | Completion date: February 21, 2014 | Current use: Manufacturing, tenant remodel | Permit id: Pmt2010-02878 | |||||
SCORE 95 Provide temperature and humidity control in existing silicone lab. To include installation of new fcu rcu on roof for temperature and humidity control. Installation of door seals and new ceiling tile. Client: Corporatio Ball | Permit type: Building, electrical, mechanical | Permit status: N&v | Current use: Manufacturing, tenant remodel | Permit id: Pmt2010-04067 | |||||
Bore accross commerce to place 2inch fiber conduit job# 1223u27-aqcb Date: December 2, 2011 Client: Corporatio Ball | Permit type: Right-of-way | Permit status: Iss | Current use: Research & development, existing | Permit id: Pmt2011-05200 | |||||
SCORE 100 Install emergency generator. Fence screening is on separate permit number pmt2000-03691. Client: Ball | Permit type: Electrical | Permit status: N&v | Current use: Manufacturing, existing | Permit id: Pmt2000-03689 | |||||
SCORE 100 Install 7 foot high fence to enclose generator. Reference permit number pmt2000-03689 for drawings and review materials. Client: Ball Corporation | Permit type: Fence | Permit status: Cmp | Completion date: March 7, 2001 | Current use: Manufacturing, existing | Permit id: Pmt2000-03691 | |||||
SCORE 95 Add new fire alarm system. Permit is for mechanical venting and associated electrical. 1834sf Client: Corporatio Ball | Permit type: Building, electrical, mechanical | Permit status: N&v | Current use: Research & development, tenant remodel | Permit id: Pmt2005-04132 | |||||
SCORE 99 Installation of split system chiller unit to cool computer room. Client: Corporatio Ball | Permit type: Electrical, mechanical | Permit status: Cmp | Completion date: December 27, 2007 | Current use: Research & development, existing | Permit id: Pmt2007-02718 | |||||
SCORE 95 Tenant remodel of 2186 sf, add partition wall to existing conference room area, and convert storage area to a humidified electronics r & d lab. Client: Corporatio Ball | Permit type: Building, electrical, mechanical | Permit status: Cmp | Completion date: June 30, 2008 | Current use: Research & development, tenant remodel | Permit id: Pmt2008-00560 | |||||
SCORE 98 Tennant finish sprinkler ball aerospace Client: Corporatio Ball | Permit type: Fire | Permit status: Cmp | Completion date: June 2, 2009 | Current use: Office - technical, existing | Permit id: Pmt2008-01624 |