Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Administrative permit ![]() Client: Sheldon Street Properties | Permit status: Expired | Permit id: 571461 | |||||
Zoning/use permit ![]() Client: Sheldon Street Properties | Permit status: Completed | Permit id: 521476 | |||||
New construction permit ![]() Client: Sheldon Street Properties | Permit status: Active | Permit id: 521540 | |||||
Mechanical permit ![]() Client: Sheldon Street Properties | Permit status: Active | Permit id: 603119 | |||||
Electrical permit ![]() Client: Sheldon Street Properties | Permit status: Completed | Permit id: 617157 | |||||
Suppression permit ![]() Client: Sheldon Street Properties | Permit status: Active | Permit id: 563945 | |||||
Plumbing permit ![]() Client: Sheldon Street Properties | Permit status: Active | Permit id: 574979 | |||||
Suppression permit ![]() Client: Sheldon Street Properties | Permit status: Expired | Permit id: 563945 | |||||
Administrative permit ![]() Client: Sheldon Street Properties | Permit status: Expired | Permit id: 571461 | |||||
Electrical permit ![]() Client: Sheldon Street Properties | Permit status: Completed | Permit id: 617157 | |||||
Plumbing permit ![]() Client: Sheldon Street Properties | Permit status: Expired | Permit id: 574979 | |||||
Zoning use permit ![]() Client: Sheldon Street Properties | Permit status: Completed | Permit id: 521476 | |||||
Mechanical permit ![]() Client: Sheldon Street Properties | Permit status: Active | Permit id: 603119 | |||||
New construction permit ![]() Client: Sheldon Street Properties | Permit status: Expired | Permit id: 521540 | |||||
SCORE 93 Recess, outlets, switches, 2 amp service, 7 smoke detectors, all in compliance with nec 2008 ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 617157 | |||||
For the erection of an attached structure (maximum height nte 38 ft) with cellar, and a projected bay at front 2nd through 3rd floor and accessory roof deck with roof access pilothouse (pilothouse contain stairs and landing only & maximum height ft. Roof decks set back at least five ft. From the extreme front building line). Size and location as shown in the application. Use for a single family dwelling with one accessory interior off street parking space. ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 4, 2014 | Permit id: 521476 | |||||
SCORE 100 Ct,lateral,1" water service pa201432103 (sfd)"self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: April 27, 2017 | Permit id: 574979 | |||||
SCORE 86 For the installation of a one (1) inch fire service line w. Backflow preventor (bfp) assembly and for installation of a fire suppression system as per nfpa 13r. All work shall be in accordance with approved plans. See ap#544572 for plans, hydraulic calculation, and supporting documentation. ![]() ![]() Permit type: Suppression permit | Permit status: Expired | Completion date: May 19, 2017 | Permit id: 563945 | |||||
To amend building permit #5215 for changes to interior partitions and 1st floor elevation change as per approved plans. ![]() Permit type: Administrative permit | Permit status: Expired | Completion date: April 19, 2016 | Permit id: 571461 | |||||
SCORE 100 Installation of (2) hvac units; 80,0 btu; 90% furnaces (including ductwork associated accessories). Sfd ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: April 27, 2017 | Permit id: 603119 | |||||
For the erection of four (4) story single family family dwelling with roof deck, pilot house and one (1) interior garage space as per approved plans. Must be sprinklered throughout in accordance with nfpa 13r see a p 521538 for plans separate permits required for mep and fire suppression ![]() Permit type: New construction permit | Permit status: Completed | Completion date: July 25, 2017 | Permit id: 521540 |