Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Demolition permit Date: July 15, 2016 Permit status: Active | Permit id: 707081 | |||||
Alteration permit Date: January 12, 2017 Permit status: Active | Permit id: 737189 | |||||
Demolition permit Date: July 15, 2016 Permit status: Expired | Permit id: 707081 | |||||
SCORE 61 To amend permit number 737189 to eliminate all alterations to the roof and to eliminate associated welding special inspections. Date: June 29, 2017 Contractor: Post A Nd Beam Llc Permit type: Administrative permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 780594 | |||||
SCORE 89 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Installation of (4) hvac systems and new duct work. Installation of gas piping for restaurant. Date: April 19, 2017 Contractor: City Plumbing Llc Permit type: Mechanical permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 775940 | |||||
SCORE 89 Curb trap and fai pa20170801225 (restaurant)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: March 22, 2017 Contractor: City Plumbing Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 768668 | |||||
SCORE 100 For the installation of (1) ul 3 listed wet chemical extinguishing system with thirteen (13) flow points in accordance with nfpa 17a. Fire supression system to serve one (1) commercial kitchen exhaust hood system in a restaurant in the first floor kitchen area of an existing structure. Date: February 16, 2017 Contractor: East Coast Business Fire Inc Permit type: Suppression permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 756957 | |||||
SCORE 100 Installation of one (1) commercial kitchen exhaust hood with supply exhaust tie-in to one (1) return air fan, one (1) exhaust fan & all associated return exhaust ductwork. Separate permit shall be required for installation of an approved automatic fire supression system Date: February 16, 2017 Contractor: East Coast Business Fire Inc Permit type: Mechanical permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 756953 | |||||
SCORE 100 Install 400amp service install light fixtures, light switches, gfcis & outlet and branch circuits thru out, fire alarm thru out as per 2008 nec (south district) Date: March 6, 2017 Contractor: Gerald Kaewell Permit type: Electrical permit | Permit status: Completed | Completion date: August 11, 2017 | Permit id: 756185 | |||||
SCORE 100 Automatic sprinkler system install w. Two (2) inch fire service line & four (4) inch backflow prevention (bfp) assembly to serve previously approved restaurant space. Automatic sprinkler system install per nfpa 13. Date: March 15, 2017 Contractor: B. M. Consulting Services Inc Permit type: Suppression permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 755566 | |||||
SCORE 89 Alteration: interior plumbing for the fit-out of a sit-down restaurant on the basement, 1st & 2nd floors of an existing 2-story building. The installation shall comply with the philadelphia plumbing code, 2004. Fuel gas piping and equipment is not part of this permit and requires a mechanical permit. Date: March 8, 2017 Contractor: City Plumbing Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: August 12, 2017 | Permit id: 753185 | |||||
Prescriptive alterations to an existing space for use as a sit down restaurant (no change in occupancy). Alterations to include demolition and erection on nonbearing partitions, accessibility upgrades (interior), finishes, millwork and structural alterations at the roof level to accommodate future mechanical equipment. Structure to be fully sprinklered. All work per plans approved by philadelphia historical commission. Amended permit required to document special inspectors. Separate permits required to plumbing, mechanical, electrical and fire suppression. Date: January 12, 2017 Permit type: Alteration permit | Permit status: Completed | Completion date: August 11, 2017 | Permit id: 737189 | |||||
SCORE 96 Interior demo of non-load bearing walls only, no structural work on this permit Date: July 15, 2016 Contractor: James Dibartolo Permit type: Demolition permit | Permit status: Completed | Completion date: April 17, 2017 | Permit id: 707081 |