Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 98 Remove faultly original a c break and furnish and install one (1) new hoister whitney d c brake, furnish and install & wire d c to existing controller check and adjust floor leveling perform full load governor safety test,on one (1) 1200lb. Cap, ewgt, 4-floor passenger elevator. Do not return elevator to service until city of chicago, department of buildings, elevator bureau witness of testing. Pursuant to the scope of work submitted. Ev006007 Permit type: Permit - elevator equipment | Permit id: 100679801 | |||||
SCORE 98 Existing motor failed category 5 testing because it was unable to pick the 1200lb. Rated capacity load remove existing motor bring to machine shop to either repair or if needeed, replace with new motor. Schedule re-inspection, perform category 5 full load governor test with city of chicago inspector. Pursuant to the scope of work submitted. Ev006007 Permit type: Permit - elevator equipment | Permit id: 100688809 |