Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit Date: July 5, 2016 Client: University City Assoc | Permit status: Completed | Permit id: 702041 | |||||
Administrative permit Date: July 21, 2016 Client: University City Assoc | Permit status: Completed | Permit id: 702046 | |||||
Zoning use permit Date: July 5, 2016 Permit status: Completed | Permit id: 702041 | |||||
Administrative permit Date: July 21, 2016 Permit status: Completed | Permit id: 702046 | |||||
SCORE 86 Install 100amp temp service with 100amp 12 circuit panel, 10-20amp gfcis for use for construction of new building service will be in place for 6 months as per 2008 nec (west district) Date: June 12, 2017 Contractor: Hassan Electric Llc Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2017 | Permit id: 790997 | |||||
SCORE 99 For the erection of a five (5) story above grade plane, w. Enclosed parking garage & support space basement, mixed-use multi-family dwelling for apartment units & below-grade parking garage of light frame fire-retardant treated wood (frtw) & shear wall construction w. Reinforcend concrete composite, structural steel & reinforced concrete foundation system building; building to be fully sprinklered alongside stanpipe system. Separate permit reqd for any mech., elec., plumb. & firesupp work. All means of pedestrian protection to be in place prior to commencement of any permitted work. Date: March 10, 2017 Contractor: Turn Key Realty Llc Permit type: New construction permit | Permit status: Active | Completion date: September 19, 2017 | Permit id: 714706 | |||||
SCORE 79 Install (45) heat pumps with ductwork. No penetrations & units are self contained. (mixed-use) Date: November 18, 2017 Contractor: Jesse Fritz Airtight Heating Permit type: Mechanical permit | Permit status: Active | Completion date: November 18, 2017 | Permit id: 833366 | |||||
SCORE 93 New construction: exterior & interior plumbing of a 5-story muti-family structure with an enclosed garage and (45) dweling uints. The installation includes a 3" domestic water distribution service and a 8" combined sewer lateral to the street mains, as well as a 3" backflow prevention containment assembly, on the main domestic water supply. The installation will comply with the philadephia plumbing code, 2004. Date: August 23, 2017 Contractor: M E B Plumbing Permit type: Plumbing permit | Permit status: Active | Completion date: October 10, 2017 | Permit id: 789081 | |||||
SCORE 100 For the installation of a 4-inch fire service line for an automatic fire suppression sprinkler system with a backflow prevention assembly in accordance with nfpa 13 and manual wet standpipes in accordance with nfpa 14 as per plan. Date: May 25, 2017 Contractor: Elite Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: June 22, 2017 | Permit id: 782140 |