Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit Date: January 28, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Expired | Permit id: 586940 | |||||
Alteration permit Date: June 10, 2014 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 539950 | |||||
Electrical permit Date: February 20, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 591662 | |||||
Plumbing permit Date: January 22, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 585969 | |||||
Alteration permit Date: July 14, 2009 Client: Ernest Rollins | Permit status: Completed | Permit id: 226320 | |||||
Electrical permit Date: March 23, 2010 Client: Ernest Rollins | Permit status: Expired | Permit id: 268434 | |||||
Alteration permit Date: January 22, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 585918 | |||||
Plumbing permit Date: January 22, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 585968 | |||||
Electrical permit Date: March 23, 2010 Client: Henry J Ham | Permit status: Expired | Permit id: 268434 | |||||
Electrical permit Date: February 20, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Expired | Permit id: 591655 | |||||
Alteration permit Date: June 10, 2014 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 539950 | |||||
Alteration permit Date: July 14, 2009 Client: Ernest Rollins | Permit status: Completed | Permit id: 226320 | |||||
Alteration permit Date: January 22, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 585918 | |||||
Mechanical permit Date: January 28, 2015 Client: Partnership, Preservationassociation, L.P. | Permit status: Completed | Permit id: 586940 | |||||
SCORE 100 Replacement of all switches,recepts and lighting fixtures,new phone and tv cable lines,bath exhaust fan and range exhaust hood,1 circuit to kitchen circuit for ac unit as per 2008 nec (west district) Date: February 20, 2015 Contractor: Mecca Electric Inc Client: Partnership, Preservationassociation, L.P. | Permit type: Electrical permit | Permit status: Expired | Completion date: February 20, 2015 | Permit id: 591655 | |||||
SCORE 82 Replacing 2 water heaters,2 toilets,2 lav sinks,2 kitchen sinks and tub facuets (two family)the installation will comply with the philadelphia plumbing code 2004 Date: February 2, 2015 Contractor: Tom Campbell Plumbing Llp Client: Partnership, Preservationassociation, L.P. | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 587980 | |||||
SCORE 82 Replacement of all fixtures 2 water heater,2 wc,2 lav sinks and 2 kitchen sinks (two family)the installation will comply with the philadelphia plumbing code 2004 Date: January 22, 2015 Contractor: Tom Campbell Plumbing Llp Client: Partnership, Preservationassociation, L.P. | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 586021 | |||||
SCORE 89 Furnish and install (20) gas furnaces, (20) air conditioning coil and condensers mounted on roof . Furnish and install (20) bathroom exhaust fans. Replace all feed and return registers (all penetrations must be fire caulked) Date: January 28, 2015 Contractor: Murphys Plumbing And Heating Inc Client: Partnership, Preservationassociation, L.P. | Permit type: Mechanical permit | Permit status: Completed | Completion date: January 18, 2017 | Permit id: 586940 | |||||
SCORE 82 Replace 2-toilets, 2-lavs, 2-kit sinks, 2-tub faucets & 2-water heaters note: the installation will comply with the philadelphia plumbing code 2004 Date: January 22, 2015 Contractor: Tom Campbell Plumbing Llp Client: Partnership, Preservationassociation, L.P. | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 585962 | |||||
SCORE 100 Replacement of all switches,recepts and lighting fixtures,new phone and tv cable lines,bath exhaust fan and range exhaust hood,1 circuit to kitchen circuit for ac unit onto existing 100amp service as per 2008 nec (west district) Date: February 20, 2015 Contractor: Mecca Electric Inc Client: Partnership, Preservationassociation, L.P. | Permit type: Electrical permit | Permit status: Completed | Completion date: May 4, 2015 | Permit id: 591663 | |||||
SCORE 100 Install 100a service, proper grounding, 26 receptacles, 25 light fixtures, 7 120v smoke detectors, 3 phone data jacks & switches. Date: March 23, 2010 Contractor: Jamal Truesdale Client: Walker Robin D | Permit type: Electrical permit | Permit status: Expired | Completion date: March 23, 2010 | Permit id: 268434 | |||||
Interior demolition of non bearing partitions only. No structural is included on this permit,replace with new sheet rock through-out,framing were needed. Applicant agrees to limit the construction to comply with the ez permit standard for alteration dated february 2007 (attached) deviation from this "standard" will result in revocation of this permit and imposition of further penalties. This does not include havc,electrical,plumbing,these will require separate permits. Date: July 14, 2009 Client: Walker Robin D | Permit type: Alteration permit | Permit status: Completed | Completion date: December 27, 2011 | Permit id: 226320 | |||||
SCORE 84 Level 1 alterations to include; minor alteration to kitchen, new interior finishes (floor & paint), new interior doors and hardware,new kitchen cabinets, weather stripping and caulk and replace all detoriated wood sills, aprons. Installing new replacemet windows. (no change to opening sizes) Date: June 10, 2014 Contractor: Columbus Property Management Client: Partnership, Preservationassociation, L.P. | Permit type: Alteration permit | Permit status: Completed | Completion date: April 30, 2015 | Permit id: 539950 | |||||
SCORE 100 Remove and dispose of existing roofing install 1. 5"polyiso insulation install a fully adhered . 0 tpo roof system install new 24 gauge gravel stop Date: January 22, 2015 Contractor: Topline Construction Client: Partnership, Preservationassociation, L.P. | Permit type: Alteration permit | Permit status: Completed | Completion date: April 21, 2015 | Permit id: 585918 | |||||
SCORE 89 Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb 2007. Deviations from this standard will result in the revocation o fthis permit and imposition of further penalties. (sfd) Date: December 4, 2017 Contractor: Sab Construction And Management Client: Philadelphia Lotus 2 Llc | Client Company: Cal 750424 | Permit type: Alteration permit | Permit status: Active | Completion date: December 4, 2017 | Permit id: 836646 | |||||
SCORE 100 Install (1) gas furnace with ductwork. (sfd) Date: December 5, 2017 Contractor: Above And Below Heating And Air Client: Philadelphia Lotus 2 Llc | Client Company: Cal 750424 | Permit type: Mechanical permit | Permit status: Active | Completion date: December 5, 2017 | Permit id: 836929 | |||||
SCORE 82 100amp service and rewire with outlets lights switches fixtures smoke co detectors per 2008 nec (sfd) Date: December 12, 2017 Contractor: Terox Electric And Construction Client: Philadelphia Lotus 2 Llc | Client Company: Cal 750424 | Permit type: Electrical permit | Permit status: Active | Completion date: December 12, 2017 | Permit id: 837858 | |||||
SCORE 100 1. 5 bath and kitchen (potable water and drain)(sfd)the installation will comply with the philadelphia plumbing code 2004 Date: December 8, 2017 Contractor: Shegda Construction Corp Client: Philadelphia Lotus 2 Llc | Client Company: Cal 750424 | Permit type: Plumbing permit | Permit status: Active | Completion date: December 8, 2017 | Permit id: 838072 |