Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Alteration permit Date: July 17, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 87297 | |||||
Operations permit Date: April 24, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 22273 | |||||
Electrical permit Date: January 31, 2011 Client: Philadelphia University | Permit status: Completed | Permit id: 317683 | |||||
Mechanical permit Date: June 28, 2016 Client: Philadelphia University | Permit status: Active | Permit id: 700659 | |||||
Plumbing permit Date: July 15, 2016 Client: Philadelphia University | Permit status: Completed | Permit id: 699699 | |||||
Electrical permit Date: February 9, 2010 Client: Philadelphia University | Permit status: Completed | Permit id: 258825 | |||||
Suppression permit Date: April 3, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 462950 | |||||
Suppression permit Date: August 14, 2012 Client: Philadelphia University | Permit status: Completed | Permit id: 415296 | |||||
Electrical permit Date: August 7, 2008 Client: Philadelphia University | Permit status: Completed | Permit id: 168981 | |||||
Operations permit Date: September 21, 2011 Client: Philadelphia University | Permit status: Completed | Permit id: 21145 | |||||
Operations permit Date: October 22, 2009 Client: Philadelphia University | Permit status: Completed | Permit id: 19971 | |||||
Electrical permit Date: July 19, 2016 Client: Philadelphia University | Permit status: Active | Permit id: 695168 | |||||
Operations permit Date: October 1, 2014 Client: Philadelphia University | Permit status: Completed | Permit id: 23189 | |||||
Electrical permit Date: September 12, 2007 Client: Philadelphia University | Permit status: Expired | Permit id: 91260 | |||||
Electrical permit Date: March 11, 2014 Client: Philadelphia University | Permit status: Expired | Permit id: 523548 | |||||
Operations permit Date: September 23, 2008 Client: Philadelphia University | Permit status: Completed | Permit id: 12878 | |||||
Electrical permit Date: July 23, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 477187 | |||||
Demolition permit Date: January 4, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 47882 | |||||
Suppression permit Date: August 21, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 87278 | |||||
Electrical permit Date: January 31, 2011 Client: Philadelphia University | Permit status: Completed | Permit id: 317683 | |||||
Demolition permit Date: January 4, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 47882 | |||||
Suppression permit Date: April 3, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 462950 | |||||
Electrical permit Date: September 12, 2007 Client: Philadelphia University | Permit status: Expired | Permit id: 91260 | |||||
Mechanical permit Date: June 3, 2016 Client: Philadelphia University | Permit status: Active | Permit id: 697349 | |||||
Operations permit Date: October 22, 2009 Client: Philadelphia University | Permit status: Completed | Permit id: 19971 | |||||
Electrical permit Date: June 21, 2010 Client: Philadelphia University | Permit status: Completed | Permit id: 276803 | |||||
Electrical permit Date: July 23, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 477187 | |||||
Suppression permit Date: August 14, 2012 Client: Philadelphia University | Permit status: Completed | Permit id: 415296 | |||||
Alteration permit Date: July 17, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 87297 | |||||
Operations permit Date: September 21, 2011 Client: Philadelphia University | Permit status: Completed | Permit id: 21145 | |||||
Operations permit Date: September 23, 2008 Client: Philadelphia University | Permit status: Completed | Permit id: 12878 | |||||
Electrical permit Date: July 1, 2008 Client: Philadelphia University | Permit status: Expired | Permit id: 157946 | |||||
Operations permit Date: April 24, 2013 Client: Philadelphia University | Permit status: Completed | Permit id: 22273 | |||||
Electrical permit Date: July 19, 2016 Client: Philadelphia University | Permit status: Expired | Permit id: 695168 | |||||
Electrical permit Date: March 11, 2014 Client: Philadelphia University | Permit status: Expired | Permit id: 523548 | |||||
Plumbing permit Date: July 15, 2016 Client: Philadelphia University | Permit status: Completed | Permit id: 699699 | |||||
Suppression permit Date: August 21, 2007 Client: Philadelphia University | Permit status: Completed | Permit id: 87278 | |||||
Operations permit Date: October 1, 2014 Client: Philadelphia University | Permit status: Completed | Permit id: 23189 | |||||
SCORE 87 Interior alterations to create additional rooms in each dwelling unit. Date: December 6, 2007 Contractor: Nason Construction Inc Client: Philadelphia University | Permit type: Alteration permit | Permit status: Completed | Completion date: August 19, 2008 | Permit id: 116358 | |||||
SCORE 100 9 30 08 - tent erected on site for dinner seating area Date: September 23, 2008 Contractor: Knight Enterprises Inc Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 12878 | |||||
SCORE 100 Install auto sprinklers in the basement of mott hall Date: August 21, 2007 Contractor: Oliver Sprinkler Co Inc Client: Philadelphia University | Permit type: Suppression permit | Permit status: Completed | Completion date: October 4, 2007 | Permit id: 87278 | |||||
SCORE 87 Interior alterations to create additional rooms in each dwelling unit. Date: July 17, 2007 Contractor: Nason Construction Inc Client: Philadelphia University | Permit type: Alteration permit | Permit status: Completed | Completion date: August 23, 2007 | Permit id: 87297 | |||||
SCORE 91 Install 2 data lines to 18 dorms - total of 36 runs are 1 long. Install 3 duplexs in new room. Install 1 new sw, replace existing ceiling light with a new one. (north dist) Date: September 12, 2007 Contractor: George White Jr Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: September 12, 2007 | Permit id: 91260 | |||||
SCORE 100 Relocate 3 sprinkler heads on ground floor Date: April 3, 2013 Contractor: Oliver Sprinkler Co Inc Client: Philadelphia University | Permit type: Suppression permit | Permit status: Completed | Completion date: August 10, 2013 | Permit id: 462950 | |||||
SCORE 100 Install main , line piping and 137 sprinkler heads on the 1st thru 3rd floors of pertridge hall of philadelphia university as per plans. Date: August 14, 2012 Contractor: Oliver Sprinkler Co Inc Client: Philadelphia University | Permit type: Suppression permit | Permit status: Completed | Completion date: October 29, 2012 | Permit id: 415296 | |||||
SCORE 100 Installing 12 grds to existing ductwork in space-ez permit ductwork & warm-air appliances- for the installation of new ductwork, r egisters grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: June 3, 2016 Contractor: Edward B Oreilly And Assoc Inc Client: Philadelphia University | Permit type: Mechanical permit | Permit status: Expired | Completion date: August 16, 2017 | Permit id: 697349 | |||||
SCORE 100 Replace blown generator with new and replace old ats with new per 2008 nec (university) Date: March 11, 2014 Contractor: Shoreline Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: March 11, 2014 | Permit id: 523548 | |||||
SCORE 100 Provide electrical install & mod for renov of 2 rooms including branch w wiring, devices, lighting, & phone & data & fire alarm relocations as per nec 2008 & nfpa 72 (school) Date: July 23, 2013 Contractor: Arrow Electric Services Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: October 3, 2013 | Permit id: 477187 | |||||
SCORE 100 Modifications to an existing hvac system an associated duct work, piping, and seven (7) registers diffusers, per approved plans. Separate permit required for any changes to electrical, plumbing, fire suppression systems. Date: June 28, 2016 Contractor: Edward B Oreilly And Assoc Inc Client: Philadelphia University | Permit type: Mechanical permit | Permit status: Expired | Completion date: August 5, 2016 | Permit id: 700659 | |||||
SCORE 100 Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: June 28, 2017 Contractor: Oliver Sprinkler Co Inc Client: Philadelphia University | Permit type: Suppression permit | Permit status: Active | Completion date: July 19, 2017 | Permit id: 795654 | |||||
SCORE 100 Interior demolition - 1st floor althouse (phila. Univ.) Date: January 4, 2007 Contractor: M R Rose Construction Inc Client: Philadelphia University | Permit type: Demolition permit | Permit status: Completed | Completion date: February 8, 2007 | Permit id: 47882 | |||||
SCORE 91 Install 36 data cables to 18 dorm rooms, 35 coax cables, 3 receptacles in each of 17 rooms, 17 light switches & 34 light fixtures. Date: June 11, 2008 Contractor: George White Jr Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: October 15, 2008 | Permit id: 154091 | |||||
SCORE 96 Remove old lighting, install new (139) lt fixtures, (5) emerg battery units, (13) sw, (2) o. S., (46) outlets, (20) rec cord outlets, (10) equip hook-ups, (3) new panels, hvac feeds, (320) combo tele data outlets as per 2005 nec (north dist) Date: July 1, 2008 Contractor: James Carrigan Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: July 1, 2008 | Permit id: 157946 | |||||
SCORE 100 Replacement of 25kw generator with 200kw generator per attached drawings as per 2005 nec (north district) Date: February 9, 2010 Contractor: Ford Robert Electric Co Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: November 26, 2010 | Permit id: 258825 | |||||
SCORE 100 Hook up (80) new air conditioners, hook up (4) amp,277 volt panels, hook up (1) 75kva transformer, (1) 1 amp 120 208v panel, hook up (38) 1 x 4 fixtures as per 2008 nec Date: July 5, 2011 Contractor: Albarell Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2011 | Permit id: 343015 | |||||
SCORE 100 Install 1000amp, 208 1 volt, 3 phase, 4 wire service, 8 branch panels, wiremold raceway and devices, approx 2 light fixtures as per 2008 nec (north district) Date: June 21, 2010 Contractor: Albarell Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: September 16, 2010 | Permit id: 276803 | |||||
SCORE 100 Install new underground conduit and from from peco to new transformer, install new outdoor switchboard refeed 3 existing bldgs, only 2 bldgs will get new cable, the 3rd bldg is conduit only as per 2005 nec (north dist) Date: April 8, 2010 Contractor: Carr And Duff Co Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: November 27, 2015 | Permit id: 267355 | |||||
SCORE 100 10 09 2014 erect assembly tents (40x80) (40x80) philadelphia university Date: October 1, 2014 Contractor: Anthony Rental And Sales Inc Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 23189 | |||||
SCORE 100 9 23 09-erection of (1)-30x45 and (1)-12x assembly use tent - power to be supplied via existing gfi outlets Date: October 22, 2009 Contractor: Knight Enterprises Inc Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 19971 | |||||
SCORE 100 04 30 13 erect assembly tent at philadelphia university henry avenue Date: April 24, 2013 Contractor: Anthony Rental And Sales Inc Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 22273 | |||||
SCORE 96 6 new combination speaker strobes, 2 new strobes, 1 existing combo speaker strobe remove as nfpa72 (north district) Date: August 7, 2008 Contractor: James Carrigan Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: September 17, 2008 | Permit id: 168981 | |||||
SCORE 100 Install fire alarm system per nfpa 72 and plans Date: August 20, 2010 Contractor: Albarell Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: August 20, 2010 | Permit id: 290781 | |||||
SCORE 100 Replace existing generator with new larger generator, install new transfer switches (2), as per 2008 nec (north dist) Date: January 31, 2011 Contractor: Shoreline Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: April 18, 2011 | Permit id: 317683 | |||||
SCORE 100 Install (1) new 200kw backup generator,12 amp transfer swithe,install (1)1 section of duct bank from existing manhole to new generator pad location, install new pad for generator per drawings and site plan, as per 2008 nec Date: June 6, 2011 Contractor: Shoreline Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: September 9, 2011 | Permit id: 339774 | |||||
SCORE 100 Provide power to new mechanical equipment including 3 vfds,6 heat pumps,3 fans,6 pumps and power to 1 cooling tower per 2008 nec (university)north district Date: July 19, 2016 Contractor: Vision Electrical Contractors Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: July 19, 2016 | Permit id: 695168 | |||||
SCORE 100 Furnish and install 6 photo senser smoke,3 heat sensor, 4 horn strobe, 4 relay, 4 modules in dorm elevator lobbies as per 2008 nec,nfpa-72 Date: August 5, 2011 Contractor: Albarell Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Completed | Completion date: September 12, 2011 | Permit id: 354329 | |||||
SCORE 100 09 29 2011 erection of (2) assembly use tents Date: September 21, 2011 Contractor: Taylor Rental 1309 Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 21145 | |||||
SCORE 100 Install kw generator, ats, 2-panes, 1-30kva xfmr & control cable as per nec 2008 Date: August 27, 2013 Contractor: Shoreline Electric Inc Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: August 27, 2013 | Permit id: 485495 | |||||
SCORE 100 10 04 2013 erect assembly tent (40x216) for philadelphia university Date: October 3, 2013 Contractor: Anthony Rental And Sales Inc Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 22588 | |||||
SCORE 100 10 1 09-erection of (2) assembly use tents Date: September 25, 2009 Contractor: Taylor Rental 1309 Client: Philadelphia University | Permit type: Operations permit | Permit status: Completed | Permit id: 19889 | |||||
SCORE 100 Install new underground feeder to transformer for seed building as per 2005 nec (north dist) Date: April 13, 2010 Contractor: Carr And Duff Co Client: Philadelphia University | Permit type: Electrical permit | Permit status: Expired | Completion date: April 13, 2010 | Permit id: 267780 | |||||
SCORE 100 To install a drain in the window well for the rain water & connect to the existing storm water pipe, away - "self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection". Date: July 15, 2016 Contractor: Nagellavin Inc Client: Philadelphia University | Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 699699 |