Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Excavation for waterproofing. 1 call miss utility. 2 excavate down to footer at exterior front of house and along existing retaining wall. 3 seal holes and cracks that may have formed within foundation walls. 4 scarify walls to remove any existing waterproofing or loose parging. 5 installation of 1/2inch parge coat from grade line to footer. 6 installation of hlm 50 waterproof membrane. 7 installation of drainage board. 8 installation of 4inch perforated drainage pipe with no. 57stone, wrapped in filter fabric, along footer and retaining wall. 9 tie down-spouts into 4inch non-perforated drain line and daylight at front of retaining wall. Perform water test with owner present. 11 after successful water test, backfill. 12 add soil to raise grade and create a slight slope away from wall of home ? Retaining wall. ![]() Client: Linda Moore | Applicant: Chamberlin-Washington, Inc. | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1305519 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Linda L Moore | Permit status: Permit issued | Permit id: M1601549 | |||||
SCORE 96 Electrical ![]() ![]() Client: Linda L Moore | Permit status: Permit issued | Permit id: E1608524 | |||||
SCORE 86 Excavation for waterproofing. 1 call miss utility. 2 excavate down to footer at exterior front of house and along existing retaining wall. 3 seal holes and cracks that may have formed within foundation walls. 4 scarify walls to remove any existing waterproofing or loose parging. 5 installation of 1/2inch parge coat from grade line to footer. 6 installation of hlm 50 waterproof membrane. 7 installation of drainage board. 8 installation of 4inch perforated drainage pipe with no. 57stone, wrapped in filter fabric, along footer and retaining wall. 9 tie down-spouts into 4inch non-perforated drain line and daylight at front of retaining wall. Perform water test with owner present. 11 after successful water test, backfill. 12 add soil to raise grade and create a slight slope away from wall of home ? Retaining wall. ![]() ![]() Client: Linda Moore | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1305519 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Linda L Moore | Permit status: Permit issued | Permit id: M1601549 | |||||
SCORE 86 Excavation for waterproofing. 1 call miss utility. 2 excavate down to footer at exterior front of house and along existing retaining wall. 3 seal holes and cracks that may have formed within foundation walls. 4 scarify walls to remove any existing waterproofing or loose parging. 5 installation of 1 2inch parge coat from grade line to footer. 6 installation of hlm 50 waterproof membrane. 7 installation of drainage board. 8 installation of 4inch perforated drainage pipe with no. 57stone, wrapped in filter fabric, along footer and retaining wall. 9 tie down-spouts into 4inch non-perforated drain line and daylight at front of retaining wall. Perform water test with owner present. 11 after successful water test, backfill. 12 add soil to raise grade and create a slight slope away from wall of home ? Retaining wall. ![]() ![]() Client: Linda Moore | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1305519 | |||||
SCORE 97 Replace kitchen cabinets, update electrical circuits and lighting. ![]() ![]() Client: Linda Moore | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1610832 | |||||
SCORE 96 Electrical ![]() ![]() Client: Linda L Moore | Permit status: Permit issued | Permit id: E1608524 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Linda L Moore | Permit status: Permit issued | Permit id: M1601549 | |||||
SCORE 88 Plumbing and gas ![]() ![]() Client: Linda L Moore | Permit status: Completed | Permit id: P1703903 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilcfsr7yqrjrlprw4pgfimvp ![]() ![]() Client: Linda Moore | Permit type: Plumbing and gas | Permit status: Permit issued | Permit id: P62585268 |