Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Wellington mhp Date: December 14, 2011 Permit status: Closed | Permit id: 11-06203 | |||||
SCORE 88 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-06203 | Parcel: 5976 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-06203 | Parcel: 5976 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-06203 | Parcel: 5976 | |||||
October 31, 2011 10:57:59 am kneel. Wellington mhp - used mh to lot. Location: airport rd to wellington mhp.; november 3, 2011 9:42:33 am ssalyer. Removed 100. Penalty per david souther applicant states nothing on site at this time;sls; december 13, 2011 11:15:36 am mlipe. Premise number redacted phone number2 ; december 14, 2011 9:38:55 am jfortner. Wellington mhp - used mh to lot.; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck Permit type: Permits - historical | Permit status: Closed | Permit id: 11-06203 | Parcel: 5976 | |||||
Wellington mhp Date: December 14, 2011 Value: $5,000 Permit type: Historical | Permit status: Closed | Permit id: 11-06203 | |||||
October 31, 2011 10:57:59 am kneel. Wellington mhp - used mh to lot. Location: airport rd to wellington mhp.; november 3, 2011 9:42:33 am ssalyer. Removed 100. Penalty per david souther applicant states nothing on site at this time;sls; december 13, 2011 11:15:36 am mlipe. Premise number redacted phone number2 ; december 14, 2011 9:38:55 am jfortner. Wellington mhp - used mh to lot.; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck Date: December 14, 2011 Permit type: Permits - historical | Permit status: Closed | Permit id: 11-06203 | Parcel: 5976 |