| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Furnish and install 2- 160kva upss with batteries, 2- 5ton crac units, and remove 2 faulty a/c units Applicant: Todd Jewell | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1310851 | |||||
Perform soil test borings for geotechnical reason. Soil samples will be taken. Water level reading will be taken using tape. N o water samples will be taken. Four 50ft borings, 6-8" in diameter with spt soil sampling. Drilling method is hollow stem auger. Attachments detail boring locations and work plan. Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300052 | |||||
Mechanical Applicant: James D Perkins | Permit status: Completed | Permit id: M1400483 | |||||
Plumbing and gas Applicant: Thomas E Cuddeback | Permit status: Completed | Permit id: P1500359 | |||||
SCORE 93 Electrical Permit status: Permit issued | Permit id: E1308527 | |||||
SCORE 93 Mechanical Permit status: Completed | Permit id: M1400483 | |||||
SCORE 96 Plumbing and gas Permit status: Completed | Permit id: P1500359 | |||||
SCORE 96 Boiler Permit status: Permit issued | Permit id: Fb1500003 | |||||
SCORE 92 Electrical Permit status: Completed | Permit id: E1500330 | |||||
SCORE 86 Electrical Permit status: Permit issued | Permit id: E1509335 | |||||
SCORE 86 Electrical Permit status: Completed | Permit id: E1609887 | |||||
SCORE 93 Electrical Permit status: Permit issued | Permit id: E1308527 | |||||
SCORE 93 Mechanical Permit status: Completed | Permit id: M1400483 | |||||
SCORE 92 Electrical Permit status: Completed | Permit id: E1500330 | |||||
SCORE 96 Plumbing and gas Permit status: Completed | Permit id: P1500359 | |||||
SCORE 86 Electrical Permit status: Completed | Permit id: E1609887 | |||||
SCORE 56 Two geotechnical soil borings with an atv drill rig using 3. 25 inch hollow stem augers to create 6 inch annuls. Borings will be advanced to a depth of feet below existing site grades. Borings will be abandoned in accordance with doee requirements. Client: District Of Columbia | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700017 | |||||
SCORE 96 Plumbing and gas Client: United States Of America & District Of Columbia | Permit status: Completed | Permit id: P1500359 | |||||
SCORE 93 Electrical Client: United States Of America & District Of Columbia | Permit status: Permit issued | Permit id: E1308527 | |||||
SCORE 93 Mechanical Client: United States Of America & District Of Columbia | Permit status: Completed | Permit id: M1400483 | |||||
SCORE 92 Electrical Client: United States Of America & District Of Columbia | Permit status: Completed | Permit id: E1500330 | |||||
SCORE 96 Plumbing and gas Client: United States Of America & District Of Columbia | Permit status: Completed | Permit id: P1500359 | |||||
SCORE 96 Boiler Client: United States Of America & District Of Columbia | Permit status: Permit issued | Permit id: Fb1500003 | |||||
SCORE 56 Public safety communication center - replacement of existing automatic transfer switch and switchgear with true main-tie-main setup so each utilty feed has continous load to ensure supply when called to take entire building load. Remove existing diesel generator wtih associated piping and surface tank. Replace existing 2 gas generators and replace with new Client: United States Of America & District Of Columbia | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1500920 | |||||
SCORE 86 Electrical Permit status: Permit issued | Permit id: E1509335 | |||||
SCORE 56 Two geotechnical soil borings with an atv drill rig using 3. 25 inch hollow stem augers to create 6 inch annuls. Borings will be advanced to a depth of feet below existing site grades. Borings will be abandoned in accordance with doee requirements. Client: District Of Columbia | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700017 | |||||
SCORE 86 Electrical Client: United States Of America & District Of Columbia | Permit status: Completed | Permit id: E1609887 | |||||
SCORE 56 Furnish and install 2- 160kva upss with batteries, 2- 5ton crac units, and remove 2 faulty a/c units Client: United States Of America & District Of Columbia | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1310851 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeild1ekxuxv%2f2n5sakiy%2f2tix Client: District Columbia | Permit type: Electrical | Permit status: Completed | Permit id: E18589545 | |||||
SCORE 100 Interior alteration to replace/upgrade fire alarm panels and devices. Existing wiring to be reused for the dc 911 call center. Client: District Of Columbia | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1503181 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeild%2fx4v7wc1llsw%2f1fl7amam Client: Solomon Tadesse | Permit type: Electrical | Permit status: Completed | Permit id: E21695327 |