Building Permits at 2609 E Huntingdon St Philadelphia PA 191253705


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 2609 E Huntingdon St Philadelphia PA 191253705 over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
Alteration permit
Date:  December 4, 2014

Client: Seflin Gary Winter Lucy | Permit status: Expired | Permit id: 577764
2014/12/040952609 E Huntingdon St Philadelphia Pa 19125 3705
Alteration permit
Date:  March 31, 2016

Client: Seflin Gary Winter Lucy | Permit status: Active | Permit id: 680757
2016/03/310952609 E Huntingdon St Philadelphia Pa 19125 3705
Electrical permit
Date:  January 23, 2015

Client: Seflin Gary Winter Lucy | Permit status: Expired | Permit id: 586339
2015/01/230952609 E Huntingdon St Philadelphia Pa 19125 3705
Electrical permit
Date:  January 12, 2017

Client: Seflin Gary Winter Lucy | Permit status: Active | Permit id: 749390
2017/01/120952609 E Huntingdon St Philadelphia Pa 191253705
Alteration permit
Date:  March 31, 2016

Client: Seflin Gary Winter Lucy | Permit status: Completed | Permit id: 680757
2016/03/310952609 E Huntingdon St Philadelphia Pa 191253705
Alteration permit
Date:  December 4, 2014

Client: Seflin Gary Winter Lucy | Permit status: Expired | Permit id: 577764
2014/12/040952609 E Huntingdon St Philadelphia Pa 191253705
Plumbing permit
Date:  January 9, 2017

Client: Seflin Gary Winter Lucy | Permit status: Active | Permit id: 748682
2017/01/090952609 E Huntingdon St Philadelphia Pa 191253705
Electrical permit
Date:  January 23, 2015

Client: Seflin Gary Winter Lucy | Permit status: Expired | Permit id: 586339
2015/01/230952609 E Huntingdon St Philadelphia Pa 191253705
SCORE
96
Install 3 wc,3 lvas,1 tub,1 shower. 1 kitchen sink,1 laundry box,1 water heater, pvx and pex throughout (sfd)the installation will comply with the philadelphia plumbing code 2004
Date:  January 9, 2017
Contractor: Adil Elgharbaoui

Client: Seflin Gary Winter Lucy | Permit type: Plumbing permit | Permit status: Completed | Completion date: July 6, 2017 | Permit id: 748682
2017/01/090962609 E Huntingdon St Philadelphia Pa 191253705Adil Elgharbaoui
SCORE
71
16 square feet of interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. Deviations from this standard will result in the revocation of this permit and imposition of further penalties. Licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac. Call inspector at district office at least 24 hours prior to starting work.
Date:  December 4, 2014
Contractor: Eliahu Surkis

Client: Seflin Gary Winter Lucy | Permit type: Alteration permit | Permit status: Expired | Completion date: March 11, 2016 | Permit id: 577764
2014/12/040712609 E Huntingdon St Philadelphia Pa 191253705Eliahu Surkis
SCORE
100
Wire throughout, lights, switches, receptacles, tv, phone, interconnected smoke, c o detectors. Install 200a service, 30- circuits. All work in accordance with 2008 nec for a one family building
Date:  January 12, 2017

Client: Seflin Gary Winter Lucy | Permit type: Electrical permit | Permit status: Completed | Completion date: July 5, 2017 | Permit id: 749390
2017/01/1201002609 E Huntingdon St Philadelphia Pa 191253705Alb Construction Inc
SCORE
100
Install (1) heat pump with ductwork. (sfd)
Date:  January 31, 2017

Client: Seflin Gary Winter Lucy | Permit type: Mechanical permit | Permit status: Completed | Completion date: July 6, 2017 | Permit id: 755794
2017/01/3101002609 E Huntingdon St Philadelphia Pa 191253705Fresh Air Services Inc
SCORE
99
Replace service line,main service panel,replace luminares on l. R.,bath,add outlet in l. R.,bathroom add outlet in kitchen as per 2008 nec (east district)
Date:  January 23, 2015
Contractor: Vieira, Valdemar

Client: Seflin Gary Winter Lucy | Permit type: Electrical permit | Permit status: Expired | Completion date: January 23, 2015 | Permit id: 586339
2015/01/230992609 E Huntingdon St Philadelphia Pa 191253705Vieira, Valdemar
SCORE
71
Rehab interior finishes of existing home. Correct structural framing deficiencies per engineers report dated october 10,2016. See attached report. New sheetrock through out home. Remove and repalce roofing as required. New hardwood flooring. New ceramic tile in bathrooms. New paint througjhout out.
Date:  December 12, 2016
Contractor: Eliahu Surkis

Client: Seflin Gary Winter Lucy | Permit type: Alteration permit | Permit status: Completed | Completion date: July 11, 2017 | Permit id: 729923
2016/12/120712609 E Huntingdon St Philadelphia Pa 191253705Eliahu Surkis
SCORE
71
Replace masonry front 4 inch block 4 inch brick equals 8 inch masonry wall same doors same window. Masonry front wall - remove existing _ story front masonry wall 16_ x 30_. Replace with new 8 inch masonry wall, (4" brick & 4" block) on existing foundation. Windows and door same location & shall comply with the 2009 international energy efficiency code, u factor of . 35, and with emergency egress standards as per irc. New door opening for 36 inch door. Horizontal reinforcement (durawall) every 24 inches. Install returns into party walls for structural connection. Flash and seal roof to new front. Install 2 x 4 frame wall, r-13 insulation and sheetrock on interior front wall for finish. No other work allowed under this permit.
Date:  March 31, 2016
Contractor: Eliahu Surkis

Client: Seflin Gary Winter Lucy | Permit type: Alteration permit | Permit status: Completed | Completion date: January 20, 2017 | Permit id: 680757
2016/03/310712609 E Huntingdon St Philadelphia Pa 191253705Eliahu Surkis
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?