Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 Tear off: replace existing roof. Subject to field inspection Permit type: Permit - easy permit | Permit id: 100287706 | |||||
SCORE 96 Renovation of existing toilet rooms and office space in a commerical building with attached warehouse (not in contract) Permit type: Permit - renovation/ | Permit id: 100291964 | |||||
SCORE 100 Install a 30kw n g generator for the computer room. This is not a required generator. Install a 3 phase 100 amp 120 208v transfer switch. Load will tie into existing computer room panel. This generator will be outdoors with a soundproof enclosure Permit type: Permit - electric wi | Permit id: 100389350 | |||||
SCORE 100 Replace roof at east bldg (tear off) (no structural work, no mep work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit | Permit id: 100406920 | |||||
SCORE 100 Install 8ft by 1150lf wrought iron fence per lanscape (zoning) approval Permit type: Permit - easy permit | Permit id: 100461723 | |||||
Installation of 120 new power outlets for school bus block heaters in existing bus yard. Including feeders to (2) new transformers and control panels for power to bus heater outlets. Add (2) new circuit breakers in existing panel board for new feeders. Power outlets to be gfi protected on approx. 18"" pigtails.",,,,,,contractor-electrical,anchor electric corporation,291 e. St. Charles road,carol stream,il,60188,(630)682-0145,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Date: December 30, 2014 Value: $250,000 Permit type: Permit - electric wi | Permit id: 100574192 | |||||
SCORE 95 Tear off: replace existing roof. Subject to field inspection Permit type: Permit - easy permit process | Permit id: 100287706 | |||||
SCORE 100 Install a 30kw n g generator for the computer room. This is not a required generator. Install a 3 phase 1 amp 120 208v transfer switch. Load will tie into existing computer room panel. This generator will be outdoors with a soundproof enclosure Permit type: Permit - electric wiring | Permit id: 100389350 | |||||
SCORE 95 Install 8ft by 1150lf wrought iron fence per lanscape (zoning) approval Permit type: Permit - easy permit process | Permit id: 100461723 | |||||
SCORE 96 Renovation of existing toilet rooms and office space in a commerical building with attached warehouse (not in contract) Permit type: Permit - renovation/alteration | Permit id: 100291964 | |||||
SCORE 60 Installation of 1 new power outlets for school bus block heaters in existing bus yard. Including feeders to (2) new transformers and control panels for power to bus heater outlets. Add (2) new circuit breakers in existing panel board for new feeders. Power outlets to be gfi protected on approx. 18" pigtails. Permit type: Permit - electric wiring | Permit id: 100574192 | |||||
SCORE 95 Replace roof at east bldg (tear off) (no structural work, no mep work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit process | Permit id: 100406920 | |||||
SCORE 60 Retrofit 35 metal halide garage lights with led lamps. Permit type: Permit - electric wiring | Permit id: 100709134 | |||||
SCORE 56 Replace 4 rtu's Date: April 15, 2009 Contractor: Dane Transportation Permit type: Permit - easy permit process | Permit id: 100287037 | |||||
SCORE 56 Replace existing four rtu's with new carrier units,one @ 4 tons one compressor,one @ 6 tons one compressor,one @ 12 tons two compressors,and one @ 18 tons two compressors. All rtu's are air cooled,r-22,self contained,and located on the roof. Date: April 17, 2009 Contractor: Great Dane Permit type: Permit - easy permit process | Permit id: 100287248 |