Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Wellington mhp Date: January 23, 2013 Permit status: Closed | Permit id: 12-03201 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-03201 | Parcel: 6081 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-03201 | Parcel: 6081 | |||||
SCORE 88 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-03201 | Parcel: 6081 | |||||
June 7, 2012 3:31:43 pm kneel. Per phone call with leigh warlick at wellington, shoudl have been #24 not 26, location transfered. June 7, 2012 3:07:39 pm kneel. Wellington mhp - used mh to lot with hp, master approval 09-6160.; to request residential inspections call redacted phone number: manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes wat Permit type: Permits - historical | Permit status: Closed | Permit id: 12-03201 | Parcel: 6081 | |||||
Wellington mhp Date: January 23, 2013 Value: $8,000 Permit type: Historical | Permit status: Closed | Permit id: 12-03201 | |||||
June 7, 2012 3:31:43 pm kneel. Per phone call with leigh warlick at wellington, shoudl have been #24 not 26, location transfered. June 7, 2012 3:07:39 pm kneel. Wellington mhp - used mh to lot with hp, master approval 09-6160.; to request residential inspections call redacted phone number: manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes wat Date: January 23, 2013 Permit type: Permits - historical | Permit status: Closed | Permit id: 12-03201 | Parcel: 6081 |