| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Use permit Client: Jing Inc | Permit status: Completed | Permit id: 658480 | |||||
Permit for a take out restaurant on 1st floor and one (1) family dwelling on 2nd floor in an existing structure. Client: Jing Inc | Applicant: Jing Yang | Permit type: Appeal | Permit status: Granted | Completion date: June 29, 2016 | Permit id: 26809 | |||||
Use permit Client: Jing Inc | Permit status: Completed | Permit id: 658480 | |||||
Permit for a take out restaurant on 1st floor and one (1) family dwelling on 2nd floor in an existing structure. Client: Jing Inc | Applicant: Jing Yang | Permit type: Appeal | Permit status: Granted | Completion date: June 29, 2016 | Permit id: 26809 | |||||
SCORE 99 To install a new fire suppression system. For a 10-0" hood. - for the installation of new wet chemical kitchen fire suppression system as per attached standard. Deviations from these standards require submission of construction and site plans. Client: Jing Inc | Permit type: Suppression permit | Permit status: Active | Completion date: October 10, 2017 | Permit id: 820081 | |||||
SCORE 99 Installation of a type i commercial kitchen exhaust hood (10-0" length) with makeup air duct, makeup air fan at low roof, grease duct and high roof-mounted exhaust fan for a take-out restaurant. Separate permits required for fire suppression system and all electrical plumbing work. Permit # 768055 shall be abandoned if all work herein replaces that permit scope. Client: Jing Inc | Permit type: Mechanical permit | Permit status: Active | Completion date: September 27, 2017 | Permit id: 800331 | |||||
SCORE 79 For the installation of supply exhaust ductwork, registers diffusers, ahu, and all other work as per approved plans. Separate permit required for any electrical and plumbing work. Client: Jing Inc | Permit type: Mechanical permit | Permit status: Active | Completion date: September 27, 2017 | Permit id: 810143 | |||||
SCORE 96 Replacement of existing water service and combination sewer 5" and install backflow (mixed use) Client: Jing Inc | Permit type: Plumbing permit | Permit status: Completed | Completion date: June 15, 2017 | Permit id: 783327 | |||||
SCORE 99 Install new service 300amp with new 200amp panel and 150amp sub panel and rewire throughout per 2008 nec (mixed use) install fire alarm per nfpa 72 Client: Jing Inc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 8, 2017 | Permit id: 771329 | |||||
SCORE 100 Alterations: interior plumbing;take-out restaurant; first floor;dwelling unit on the second floor -the installation shall comply with the philadelphia plumbing code, 2004 Client: Jing Inc | Permit type: Plumbing permit | Permit status: Active | Completion date: September 27, 2017 | Permit id: 770970 | |||||
SCORE 79 For the installation of one (1) type i commercial cooking hood (4-0") and associated duct work per plans. Separate permit required for suppression system. Client: Jing Inc | Permit type: Mechanical permit | Permit status: Active | Completion date: June 22, 2017 | Permit id: 768055 | |||||
SCORE 79 Interior alterations for take-out restaurant on the first floor and one dwelling unit on the second floor as per approved plans. For issuance of certificate of occupancy. Separate permits required for any m. E. P. Work. Client: Jing Inc | Permit type: Alteration permit | Permit status: Active | Completion date: November 30, 2017 | Permit id: 734640 | |||||
Use as take out restaurant on first floor Client: Jing Inc | Permit type: Use permit | Permit status: Completed | Completion date: July 11, 2016 | Permit id: 658480 |