Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Drilling up to 8 borings (depths of ft) with three inch diameter, with 4 converted to temporary monitoring wells for environmental investigation. Borings will be grouted in accordance with ddoe requirements upon completion of sampling. Bentonite slurry with 2:1 ratio of bentonite powder to water. Work will be conducted on 1st street sw and r street sw in-between potomac ave sw & s street sw. Soil borings not completed as temporary wells will be backfilled/abandoned within 24-hours of sampling using a bentonite slurry (two pounds of bentonite to one gallon of water) in accordance with ddoe guidance. The grout will be installed using a tremie pipe from the bottom of the borehole to the ground surface to prevent surface water infiltration. Work will be performed under ddoe regulation and as per site plans, work plans report and ddoe/construction & schematic forms. Client: District Of Columbia-Dept. General S. District Of Columbia-Dept. General S. | Permit type: Excavation; boring t | Permit id: Pa102624 | |||||
SCORE 56 Drilling up to 8 borings (depths of ft) with three inch diameter, with 4 converted to temporary monitoring wells for environmental investigation. Borings will be grouted in accordance with ddoe requirements upon completion of sampling. Bentonite slurry with 2:1 ratio of bentonite powder to water. Work will be conducted on 1st street sw and r street sw in-between potomac ave sw & s street sw. Soil borings not completed as temporary wells will be backfilled/abandoned within 24-hours of sampling using a bentonite slurry (two pounds of bentonite to one gallon of water) in accordance with ddoe guidance. The grout will be installed using a tremie pipe from the bottom of the borehole to the ground surface to prevent surface water infiltration. Work will be performed under ddoe regulation and as per site plans, work plans report and ddoe/construction & schematic forms. Client: District Of Columbia-Dept. General S. District Of Columbia-Dept. General S. | Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: April 23, 2015 | Permit id: Pa102624 | |||||
SCORE 95 Excavation; repair gas main line Permit status: 1 | Expiration date: August 14, 2017 | Permit id: 0 | |||||
SCORE 95 Paving restoration only, 1st st sw & r st sw, 4x4 dirt cut o m 23 w of c l of first st 121 n of l of r st, p 756134 w 3197654 Permit type: Excavation; repair gas main line | Permit status: Approved (pending payment | Expiration date: August 14, 2017 | Permit id: 0 | |||||
SCORE 95 Paving restoration only, 1st st sw & r st sw, 4x4 dirt cut o m 23 w of c l of first st 121 n of l of r st, p 756134 w 3197654 Permit status: Approved (pending payment | Expiration date: August 14, 2017 | Permit id: 0 | |||||
SCORE 62 Drilling up to 8 borings (depths of ft) with three inch diameter, with 4 converted to temporary monitoring wells for environmental investigation. Borings will be grouted in accordance with ddoe requirements upon completion of sampling. Bentonite slurry with 2:1 ratio of bentonite powder to water. Work will be conducted on 1st street sw and r street sw in-between potomac ave sw & s street sw. Soil borings not completed as temporary wells will be backfilled abandoned within 24-hours of sampling using a bentonite slurry (two pounds of bentonite to one gallon of water) in accordance with ddoe guidance. The grout will be installed using a tremie pipe from the bottom of the borehole to the ground surface to prevent surface water infiltration. Work will be performed under ddoe regulation and as per site plans, work plans report and ddoe construction & schematic forms. Client: District Of Columbia-Dept. General S. District Of Columbia-Dept. General S. | Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: April 23, 2015 | Permit id: Pa102624 | |||||
SCORE 95 Paving restoration only, 1st st sw & r st sw, 4x4 dirt cut o m 23 w of c l of first st 121 n of l of r st, p 756134 w 3197654 Permit status: Permit expired | Expiration date: August 14, 2017 | Permit id: Pa207371 | |||||
SCORE 100 Construction staging area Permit status: Expired | Expiration date: November 7, 2013 | Permit id: Pa10115784 | |||||
SCORE 100 Construction staging area Permit status: Permit expired | Expiration date: November 7, 2013 | Permit id: Pa10115784 | |||||
SCORE 100 Repair water service in roadway. 9x5 Permit type: Excavation; repair water main line | Permit status: Permit expired | Expiration date: November 29, 2013 | Permit id: Pa87002 | |||||
SCORE 100 Repair water service in roadway. 9x5 Permit type: Excavation; repair water main line | Permit status: Permit expired | Expiration date: November 29, 2013 | Permit id: Pa87002 |