Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 West elevation Permit type: Permit - signs | Permit id: 100368396 | |||||
SCORE 100 Installation of illuminated single face sign centered on store front Permit type: Permit - signs | Permit id: 100368412 | |||||
SCORE 100 West elevation Permit type: Permit - signs | Permit id: 100368396 | |||||
SCORE 100 Installation of illuminated single face sign centered on store front Permit type: Permit - signs | Permit id: 100368412 | |||||
SCORE 95 Supply and install one (1) 200 amp 3 phase, 4 wire overhead service and meter fitting in back of end space 1856. Install 42 circuit panel in the existing closet in back of space. Install circuit breakers to pickup the existing circuits in the panels. Install two (2) 60 amp, 120 240 volt single phase feeds on the outside of the exterior wall to pick up the other existing panels. Install a 3 phase, 4 wire 2"" rmc conduit with four #3 0 awg thwn cu conductor riser 60 feet to weather head, properly Permit type: Permit - electric wi | Permit id: 100606335 | |||||
SCORE 95 Supply and install one (1) 2 amp 3 phase, 4 wire overhead service and meter fitting in back of end space 1856. Install 42 circuit panel in the existing closet in back of space. Install circuit breakers to pickup the existing circuits in the panels. Install two (2) amp, 120 2 volt single phase feeds on the outside of the exterior wall to pick up the other existing panels. Install a 3 phase, 4 wire 2" rmc conduit with four #3 awg thwn cu conductor riser feet to weather head, properly ground panel to city side of water main and drive a supplemental ground rod outside. This will eliminate 2 of the 3 meters for the space. Permit type: Permit - electric wiring | Permit id: 100606335 | |||||
SCORE 95 Due to water damage, replace electrical sub panel with 16 x 16 x 4 junction box and relocate existing circuits to recently installed 3 phase service panel. Permit type: Permit - electric wiring | Permit id: 100710209 |