Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Alteration permit Date: February 25, 2015 Client: Temple Lofts Lp | Permit status: Expired | Permit id: 576622 | |||||
Alteration permit Date: December 29, 2010 Client: Temple Lofts Lp | Permit status: Expired | Permit id: 315666 | |||||
Electrical permit Date: June 26, 2014 Client: Temple Lofts Lp | Permit status: Expired | Permit id: 545867 | |||||
Zoning/use permit Date: October 21, 2010 Client: Temple Lofts Lp | Permit status: Completed | Permit id: 306801 | |||||
Zoning use permit Date: October 21, 2010 Client: Temple Lofts Llc | Permit status: Completed | Permit id: 306801 | |||||
Electrical permit Date: June 26, 2014 Client: Temple Lofts Llc | Permit status: Expired | Permit id: 545867 | |||||
Alteration permit Date: February 25, 2015 Client: Temple Lofts Llc | Permit status: Active | Permit id: 576622 | |||||
Alteration permit Date: December 29, 2010 Client: Temple Lofts Llc | Permit status: Expired | Permit id: 315666 | |||||
SCORE 97 Install 200amp temp service, 1 meter socket, 1 pnael an d 4 gfi outlets as per 2008 nec (north district) Date: June 26, 2014 Contractor: Anthony Franklin Client: Temple Lofts Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: June 26, 2014 | Permit id: 545867 | |||||
SCORE 56 For level 3 interior alterations to an existing apartment building. Work to include new interior non-bearing partitions, finishes and exterior accessible ramp. Building is fully sprinklered. Separate permits required for mechanical, electrical, plumbing, and fire suppression systems. All asbestos to be treated & removed prior to commencement of work. Date: February 25, 2015 Contractor: New Concepts Constructions Inc Client: Temple Lofts Llc | Permit type: Alteration permit | Permit status: Expired | Completion date: April 20, 2017 | Permit id: 576622 | |||||
SCORE 97 Install 16 service 3 phase complete with 47 meter bank and install 600amp house panel and fire pump service as per 2008 nec (north district) Date: June 28, 2017 Contractor: Anthony Franklin Client: Temple Lofts Llc | Permit type: Electrical permit | Permit status: Active | Completion date: June 28, 2017 | Permit id: 761895 | |||||
SCORE 100 1. 5 full water service pa20172001417 (multi family)"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: July 19, 2017 Contractor: Shegda Construction Corp Client: Temple Lofts Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: August 9, 2017 | Permit id: 801223 | |||||
SCORE 89 For the installation of a fire supression system for a multi family dwelling with a garage in the ground floor level in accordance with a nfpa 13 and nfpa 14 system. Fire suppression system serviced by a four inch fire service line with a back flow preventer assembly and fire pump. Fire suppression system to include the installation of a standpipe in each exit enclosure, both standpipes are interconnected. Fire suppression system installed in accordance with nfpa 13 and nfpa 14 standard. Date: July 24, 2017 Contractor: Aqueduct Fire Protection Client: Temple Lofts Llc | Permit type: Suppression permit | Permit status: Active | Completion date: August 9, 2017 | Permit id: 764858 | |||||
SCORE 100 Alteration: interior plumbing for an existing 6-story multi-family structure with (46) dwelling units. The installation shall comply with the philadlphia plumbing code, 2004. Additional permits are required for the 2" domestic water distribution to the street main, as well as the required 2" backflow prevention containment assembly on the main domestic water supply. Date: June 5, 2017 Contractor: Shegda Construction Corp Client: Temple Lofts Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: June 29, 2017 | Permit id: 770433 | |||||
SCORE 89 Total rewire 46 apts connecting to new 200amp subpanel each per 2008 nec (apt bldg)install new fire alarm per nfpa 72 no service not wiring fire pump Date: May 23, 2017 Contractor: D And R Company Electric Llc Client: Temple Lofts Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: June 14, 2017 | Permit id: 776521 | |||||
SCORE 89 For the installation of a mechanical system to include registers diffusers, supply exhaust ductwork, roof top units, and piping work as per approved plans. Separate permit required electrical and plumbing work. Asbestos abatement required prior to commencement of work. Date: September 18, 2017 Contractor: Lcd Heating And Air Conditioning Client: Temple Lofts Llc | Permit type: Mechanical permit | Permit status: Active | Completion date: September 18, 2017 | Permit id: 791181 |