Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Plumbing permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 667034 | |||||
Administrative permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 711954 | |||||
Zoning permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 522304 | |||||
Zoning/use permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 647802 | |||||
Electrical permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 680219 | |||||
Mechanical permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 687355 | |||||
New construction permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 647805 | |||||
Suppression permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 664447 | |||||
Permit for the relocation of lot line to create six(6) lots from one(1) opa account (1210-14 n front street) and four(4) deeded lots as follows: parcel: 1, j and k (on hope street): for the erection of an attached structure; bay windows at 2nd and 3rd floors; pilot house access roof deck for a single family dwelling. Parcel g. H and f; (on front street); for the erection of an attached structure; pilot house access roof deck for a vacant commercial space (use registration permit required prior to occupancy) on first floor and two (2) apartments above. Size and location as shown in the application. Client: B2 Front Hope Lp | Applicant: Kevin Golden | Permit type: Appeal | Permit status: Granted | Completion date: July 1, 2014 | Permit id: 22660 | |||||
Zoning use permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 647802 | |||||
Suppression permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 664447 | |||||
Zoning permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 522304 | |||||
New construction permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 647805 | |||||
Mechanical permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 687355 | |||||
Plumbing permit Client: B2 Front Hope Lp | Permit status: Active | Permit id: 667034 | |||||
Administrative permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 711954 | |||||
Electrical permit Client: B2 Front Hope Lp | Permit status: Completed | Permit id: 680219 | |||||
Permit for the relocation of lot line to create six(6) lots from one(1) opa account (1210-14 n front street) and four(4) deeded lots as follows: parcel: 1, j and k (on hope street): for the erection of an attached structure; bay windows at 2nd and 3rd floors; pilot house access roof deck for a single family dwelling. Parcel g. H and f; (on front street); for the erection of an attached structure; pilot house access roof deck for a vacant commercial space (use registration permit required prior to occupancy) on first floor and two (2) apartments above. Size and location as shown in the application. Client: B2 Front Hope Lp | Applicant: Kevin Golden | Permit type: Appeal | Permit status: Granted | Completion date: July 1, 2014 | Permit id: 22660 | |||||
Temporary certificate of occupancy for the two residential units only. Client: B2 Front Hope Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: March 8, 2017 | Permit id: 759672 | |||||
SCORE 89 Install (2) hvac systems with ductwork. (dwelling units) install (1) mini split system in commercial space. Client: B2 Front Hope Lp | Permit type: Mechanical permit | Permit status: Completed | Completion date: March 8, 2017 | Permit id: 687355 | |||||
SCORE 100 Install 4 amp main service,install 4 gang meter module,install all wiring throughout mix use building as per 2008 nec (east district) install fire alarm system throughout as per nfpa 72 Client: B2 Front Hope Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: September 28, 2016 | Permit id: 680219 | |||||
SCORE 100 Installation of automatic sprinkler system with two inch (2") fire service line, backflow prevention device and fire department connection in accordance with nfpa 13 in a portion of the first floor and nfpa 13-r throughout the remainder of a four (4) story structure with basement and pilot house. Separate permits required for all electrical and plumbing work. Client: B2 Front Hope Lp | Permit type: Suppression permit | Permit status: Completed | Completion date: March 8, 2017 | Permit id: 664447 | |||||
New construction of a four (4) story attached structure with a roof deck and pilot house (for access to roof deck only) for use as a vacant commercial space (use registration and c. O. Permits required prior to occupancy) on the first floor and a two (2) family dwelling as per approved plans. Building to be fully sprinklered. Permit to include underppinning to be monitored at all times by a pa p. E. Separate permits required for mep and fire suppression work Client: B2 Front Hope Lp | Permit type: New construction permit | Permit status: Completed | Completion date: March 8, 2017 | Permit id: 647805 | |||||
For the erection of an attached structure with roof deck and pilot house (for access to roof deck only). Size and location as shown in application. For use as vacant commercial space on ground floor front (use registration permit required prior to occupancy) and two family household living. No signs on this permit. Client: B2 Front Hope Lp | Permit type: Zoning/use permit | Permit status: Completed | Completion date: November 17, 2015 | Permit id: 647802 | |||||
For the relocation of lot lines to create (4) lots into (6) for the construction of a (3), four story buildings, with commercial at 1st floor and (2) residential units above, and (3) three story sfds on hope st Client: B2 Front Hope Lp | Permit type: Zoning permit | Permit status: Completed | Completion date: July 10, 2014 | Permit id: 522304 | |||||
SCORE 100 Interior plumbing construction for a new (4)story mixed use (vacant commercial & 2-family) property - note: the backflow prevention containment device, exterior, and 5" sewer lateral 1-1 2" water distribution require separate permit(s) - the vent termination(s) at the roof deck must comply with section p-1103. 4. 1 of the philadelphia plumbing code 2004 Client: B2 Front Hope Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: March 8, 2017 | Permit id: 667034 | |||||
Temporary certificate of occupancy for units a and b only. Client: B2 Front Hope Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: November 17, 2016 | Permit id: 732988 | |||||
Tco for the two upstairs units only Client: B2 Front Hope Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: August 11, 2016 | Permit id: 711954 | |||||
SCORE 100 Install 1 1 2 backflow preventor the installation will comply with the philadelphia plumbing code 2004 Client: B2 Front Hope Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: January 31, 2017 | Permit id: 703571 | |||||
SCORE 100 Install 5" lateral,curb trap,and pipe to basement and 1. 5 water line to the basement (mixed use)pa20161193126 self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Client: B2 Front Hope Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 21, 2016 | Permit id: 690246 |