Building Permits at 12 Concord Dr, Arden, Nc 28704


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 12 Concord Dr, Arden, Nc 28704 over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
100
Wellington estates
Date:  February 12, 2014

Client: Wellington Estates | Permit type: Res: mfg. Home | Permit status: Co issued | Current use: Residential | Permit id: 13-04537 | Parcel: 247172
2014/02/12010012 Concord Dr, Arden, Nc 28704Energy Solutions Co
SCORE
100
July 24, 2013 4:21:01 pm scarver. Setting new double wide 3br/2ba-master approval 09-6160; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes water/waste line hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same
Date:  February 12, 2014

Client: Wellington Estates | Permit type: Res: mfg. Home | Permit status: Co issued | Current use: Residential | Permit id: 13-04537 | Parcel: 247172
2014/02/12010012 Concord Dr, Arden, Nc 28704R And D Modular And Mobile Const
SCORE
100
July 24, 2013 4:21:01 pm scarver. Setting new double wide 3br 2ba-master approval 09-6160; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes water waste line hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same
Date:  February 12, 2014

Client: Wellington Estates | Permit type: Res: mfg. Home | Permit status: Co issued | Current use: Residential | Permit id: 13-04537 | Parcel: 247172
2014/02/12010012 Concord Dr, Arden, Nc 28704R And D Modular And Mobile Const
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.