Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Wellington mhp used mh Date: May 7, 2012 Permit status: Closed | Permit id: 12-01991 | |||||
SCORE 88 Wellington mhp used mh Client: Wellington Mhp Used Mh | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-01991 | Parcel: 5999 | |||||
SCORE 100 Wellington mhp used mh Client: Wellington Mhp Used Mh | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-01991 | Parcel: 5999 | |||||
SCORE 100 Wellington mhp used mh Client: Wellington Mhp Used Mh | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-01991 | Parcel: 5999 | |||||
SCORE 100 Wellington mhp used mh Client: Wellington Mhp Used Mh | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 12-01991 | Parcel: 5999 | |||||
April 12, 2012 1:40:18 pm kneel. Redacted phone number2 april 12, 2012 9:53:52 am kneel. Wellington mhp - used mh to lot. Location: wellington mhp off airport rd.; april 26, 2012 11:35:16 am kneel. Amendment: add mechanical; may 7, 2012 5:07:35 pm jfortner. Wellington mhp - used mh to lot.; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes wa Permit type: Permits - historical | Permit status: Closed | Permit id: 12-01991 | Parcel: 5999 | |||||
Wellington mhp used mh Date: May 7, 2012 Value: $8,000 Permit type: Historical | Permit status: Closed | Permit id: 12-01991 | |||||
April 12, 2012 1:40:18 pm kneel. Redacted phone number2 april 12, 2012 9:53:52 am kneel. Wellington mhp - used mh to lot. Location: wellington mhp off airport rd.; april 26, 2012 11:35:16 am kneel. Amendment: add mechanical; may 7, 2012 5:07:35 pm jfortner. Wellington mhp - used mh to lot.; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final" includes wa Date: May 7, 2012 Permit type: Permits - historical | Permit status: Closed | Permit id: 12-01991 | Parcel: 5999 |