Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 73 South Capitol Street Bridge Washington Dc Nine soil borings will be performed with a geotechnical drill rig approximately 6 inches in diameter and ranging from to 1 feet in depth by hollow auger drill method. The drilling will be performed using a truck- or atv-mounted conventional drill rig each accompanied by a pickup truck. All soil borings will be drilled at least feet behind the guardrails and in tree space. Date: December 18, 2013 Contractor: Ecs Mid Atlantic Llc Client: Ch2m Hill | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: April 17, 2014 | Permit id: Pa89970 | |||||
SCORE 73 Exit 3b From Interstate 295 Northbound To Suitland Parkway Se Washington 3b Eleven soil borings will be performed with a geotechnical drill rig approximately 6 inches in diameter and ranging from approximately to 1 feet in depth by hollow auger drill method. The drilling will be performed using a truck- or atv-mounted conventional drill rig each accompanied by a pickup truck. All soil borings will be drilled at least feet behind the guardrails and in tree space. Borings rw-29, rw-31, rw-32, rw-33, rw-38, rw-39, and rw- will be drilled in the shoulder. Borings rw-30, rw-34, rw-35, and rw-36 will be drilled in tree space. Anacostia freeway, suitland parkway as per plans. Date: December 18, 2013 Contractor: Ecs Mid Atlantic Llc Client: Ch2m Hill | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: April 26, 2014 | Permit id: Pa89972 | |||||
SCORE 73 199 Block Of Potomac Avenue Sw Washington Dc Five soil borings will be performed with a geotechnical drill rig approximately 6 inches in diameter and ranging from approximately 15 to feet in depth by hollow auger drill method. The drilling will be performed using a truck- or atv-mounted conventional drill rig each accompanied by a pickup truck. Borings pv-32, pv-33, and rw-22 will be drilled in the shoulder. Borings pv- and rw-21 will be drilled in tree space. Potomac avenue,south capitol street, r street, and half street s. W. As per plans. Date: December 18, 2013 Contractor: Ecs Mid Atlantic Llc Client: Ch2m Hill | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: May 8, 2014 | Permit id: Pa89976 | |||||
SCORE 73 37 O St Nw, Washington, Dc 20057 We will perform a total of eightborings on the proposed site. The borings will be extended to depths on the order of feet below existing grades. The borings will be evenly spaced throughout the site. The borings will be drilled utilizing 3. 25-inch hollow stem, continuous flight augers. The borings will be performed utilizing an atv-mounted drill rig and will generate an approximately 6-inch annulus. Sampling will be conducted using a 2-inch o. D., split-barrel sampler driven into the soil a distance of 18 or 24 inches by a 140-pound hammer falling inches. The samples will be placed in glass jars for geotechnical classification. Additional eight infitration test will be performed at a max depth of 10ft. The purpose of the phase ii environmental site assessment is to evaluate the subsurface environment, where accessible, to determine if the past use of the property has impacted the subsurface soils and groundwater. The scope of service will involve collecting, field screening and laborato Date: June 11, 2014 Contractor: Ecs Mid Atlantic Llc Client: Presidents And Directors Of Georgetown University | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400307 | |||||
SCORE 73 23 Connecticut Ave Nw, Washington, Dc 20008 Ecs will perform 13 soil borings to a depth of 42-65ft on the property. The drilling will be performed by connelly associates. Ecs will collect 3 soil samples from each boring and 5 groundwater samples. The diameter of the borings will be 6 inches and the drilling method will be a hollow- stem auger drilling Date: February 7, 2012 Contractor: Ecs Mid Atlantic Llc Client: Government Of The Peoples Republic Of China | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1200137 |